|  Sat Oct 16 17:13:19 2004, Other, , s | 
| s | 
|  Tue Oct 12 13:00:08 2004, Curtis Ballard, Start Up, cv142 valve | 
| Curtis closes and opens slowly at about 11:00 am this morning. Wants to see if that works better than the sudden on/off switch.
 
 | 
|  Tue Oct 12 02:05:31 2004, Experimentor, Start Up, cv142 valve | 
| after only two hours since last lead cycling, they warm up quickly. ops cycles the valve, but more quickly this time, off ... 1 sec ... on.
 
 | 
|  Mon Oct 11 22:32:11 2004, Experimentor, Start Up, cv142 valve | 
| temp of leads begins its exponential rise again (caught it at 12K), approx 11 hours after last reset.  this time asked operator to shut off valve for
 3 seconds, then turn back on.
 | 
|  Mon Oct 11 11:49:34 2004, Experimentor, Start Up, cv142 valve | 
| noticed temp rise, which occured only about 5 hours after the last "reset" .... the time between resets seems to be decreasing, which is
 not a good sign.
 | 
|  Mon Oct 11 03:56:14 2004, Experimentor, Start Up, cv142 valve | 
| noticed that the lead temp rose to 24K over the past 4 hours. had control room personnle cycle the cv142 valve. temperature dropped.
 
 | 
|  Sun Oct 10 17:36:35 2004, Experimentor, Start Up, power leads | 
| At 5:30 pm sundat, power lead temp is about 10.6K.  script tool still notworking
 
 | 
|  Sat Oct  9 22:50:26 2004, Other, , power leads warmed | 
| At 10:30 PM Saturday, Donald Arseneau sees power leads at 25K, having gone up for the previous 10 hours.  (I didn't
 see it earlier because striptool wasn't scrolling).  Cycled
 | 
|  Thu Oct  7 13:33:20 2004, Doug Preddy, Start Up, turned off purifier | 
| turned off purifier | 
|  Wed Oct  6 09:25:54 2004, Doug Preddy, Start Up, switch to series mode | 
| switched to series mode | 
|  Wed Oct  6 07:57:01 2004, Doug Preddy, Start Up, parallel cold return | 
| Switched to parallel cold return at 4:00 yesterday afternoon. 6:30 this morning started closing cv155 as temps had bottomed out at 24K.
 | 
|  Tue Oct  5 07:18:16 2004, Doug Preddy, Start Up, adjust compressor discharge pressure | 
| adjusted compressor discharge pressure to 11 Bar | 
|  Mon Oct  4 09:16:29 2004, Doug Preddy, Start Up, Started turbines | 
| Started flow to the turbimes with the solenoid in parallel warm return. | 
|  Fri Oct  1 11:39:55 2004, Doug Preddy, Maintenance, Loading of compressor not working | 
| When the compressor was restarted on Monday, the remote load button would not respond. The compressor was shut off. After two days of searching the
 wiring etc. a bad connection was found on DR1 relay (upstairs in the
 | 
|  Mon Sep 13 13:56:06 2004, Doug Preddy, Shut Down, compressor off | 
| compressor off | 
|  Mon Sep 13 10:55:25 2004, Doug Preddy, Shut Down, Quench and shutdown | 
| The solenoid quenched on powerlead temps this morning at 10:00. It is warming up and the power leads are >200K.Isolating and purging the coldbox
 is not very useful now, so I am shutting the system down.
 | 
|  Fri Sep  3 01:28:43 2004, Doug Preddy, Quench Recovery, power up | 
| started flow to the power leads at 11:30. Cold and stable at 1:00am. Energized solenoid at 1:30.
 | 
|  Thu Sep  2 21:58:34 2004, Willy Andersson, Quench Recovery, Switch to series cooling | 
| Solenoid had tripped on powerlead overtemp at about 09:00 this morning. Doug recovered the system to // cooling. I switched system to series
 cooling at about 21:30. LHe level at about 10%. Buffer tank pressure is low
 | 
|  Sun Aug 29 14:39:19 2004, Doug Preddy, Normal Running, Power lead ripple | 
| The LHe in and PL-neg temps have been building up a ripple over the last few days. Curtis cycled HIC142 Friday evening at about 5:00. I just had
 the Main control room operator (Peter) cycle them again. The ripples died
 | 
|  Wed Aug 25 12:52:53 2004, Doug Preddy, Normal Running, power lead ripple | 
| Lhe ripple has started. 10.9-11.4K PL-Pos also has a smaller ripple. Both flows down to 230mm. Cycled HIC 142 and the ripple disappeared.
 Put TIC121 into auto mode.
 |