Logbooks
Lab Maintenance
Evaporator_1
Evaporator_2
Laser cutter
Target Production
Test-Stand
RH-ISAC
RH-Cyclotron
RH-Meson Hall
RH-Beamlines
RH-ARIEL
|
Target Production |
Not logged in |
 |
|
Wednesday, June 03, 2015, 10:55, Laura Lambert, ZrC#7, LP-SIS, ITW, TM2, 41177-1, , Ready, ZrC#7 target description 
|
Monday, July 06, 2015, 12:18, John Wong, ZrC#7, LP-SIS, ITW, TM2, 41177-1, , Failed, ZrC#7 target description
|
|
Message ID: 52
Entry time: Wednesday, June 03, 2015, 10:55
Reply to this: 53
|
Author: |
Laura Lambert |
Target/No.#: |
ZrC#7 |
Source: |
LP-SIS |
Station: |
ITW |
Module: |
TM2 |
Target Oven W.O#: |
41177-1 |
Heat Shield W.O#: |
|
Status: |
Ready |
Subject: |
ZrC#7 target description |
|
|
Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
|
|
|
|