353
Tue Oct 26 09:19:39 2010
Damien Gallop
26Mg6+ for TIGRESS
The TIGRESS run was scheduled to end at
08:30, but has been extended for 24h. The
ICR reports that they are getting "good
352
Mon Oct 25 09:05:15 2010
Damien Gallop
26Mg6+ for TIGRESS
Smooth delivery (from OLIS point-of-view)
to TIGRESS over the weekend. An SCB RF amplifier
failed yesterday and was replaced. Tuning
351
Fri Oct 22 09:35:24 2010
Damien Gallop
26Mg6+ for TIGRESS
A 26Mg beam was handed over to TIGRESS
last evening. It is 26Mg6+ through ISAC-I
and further stripped to 26Mg10+ by the time
350
Thu Oct 21 11:46:14 2010
Damien Gallop
26Mg6+ for TIGRESS
The MWS was restarted yesterday, and a
26Mg beam re-established. ICR set up into
ISAC-II overnight, and tuning to TIGRESS
349
Wed Oct 20 11:30:32 2010
Damien Gallop
26Mg6+ for TUDA-II
MWS ran fine overnight. It was shut off
this morning to investigate bias sparking
issue, noted on FR#4894. The two MCIS turbopump
348
Tue Oct 19 09:20:40 2010
Damien Gallop
26Mg6+ for TUDA-II
MWS operating nicely.
347
Mon Oct 18 09:22:35 2010
Damien Gallop
26Mg6+ for TUDA-II
MWS is producing 26Mg, presently parked.
It was used over the weekend
for TUDA tuning.
346
Fri Oct 15 09:23:03 2010
Damien Gallop
MWS switchover for scheduled 24/26Mg beams
Source is running nicely. Hand-off
to ICR occurred ~Wednesday night. Setup done
overnight.
345
Wed Oct 13 16:15:03 2010
Damien Gallop
MWS switchover for scheduled 24/26Mg beams
Source conditioning most of today, to 59kV.
Striptool attached. Reset to 26Mg tune at
~16:00.
344
Tue Oct 12 13:25:21 2010
Damien Gallop
MWS switchover for scheduled 24/26Mg beams
Source switchover in progress on WP#2010-10-12-1.
Magnesium material installed into MWS. Pumpdown
343
Fri Oct 8 09:35:03 2010
Damien Gallop
20Ne1+ at 40.8keV for TIGRESS
Beam from MWS quietly sitting on FC6 awaiting
tune checks to TIGRESS. Next experiments
up are 26Alg5+ to TUDA and 24Na5+ to TIGRESS.
342
Mon Oct 4 09:46:12 2010
Damien Gallop
20Ne1+ at 40.8keV for TIGRESS setup
A 20Ne1+ beam from the MWS was established
on Friday. Line tuning began Friday evening.
A tune to the front of the SC LINAC was in
341
Mon Oct 4 09:40:30 2010
Damien Gallop
OLIS Maintenance and Development completed
The September Mini-Shutdown is now a memory.
The few days available to OLIS were used
for MCIS Development on 197Au. Productive.
340
Fri Sep 24 13:22:00 2010
Damien Gallop
OLIS Maintenance and Development
Supernanogan on overnight, in the search
for gold. A trace of 197Au34 observed this
morning. Development continues.
339
Thu Sep 23 09:20:34 2010
Damien Gallop
4He1+ for DRAGON
DRAGON continues to take MWS beam.
Later... 14:00 EOB. Prepare for Mini-Shutdown.
338
Mon Sep 20 09:34:44 2010
Damien Gallop
4He1+ for DRAGON
MCIS Development finished Friday evening.
OLIS switched to MWS operation and setup
began for 4He1+ delivery to DRAGON. Beam
337
Fri Sep 17 14:02:29 2010
Damien Gallop
MCIS Development
Today's agenda: RF frequency scans and
generally getting a feel for the new sputter
source.
336
Thu Sep 16 17:06:22 2010
Damien Gallop
MCIS Development
A new sputter source was installed onto
the Supernanogan. A wire of Au is installed
in the source. Mass scans this morning with
335
Tue Sep 14 09:18:28 2010
Damien Gallop
MCIS Development
The 16O3+ DRAGON run just finished. MCIS
Development begins this morning for a few
days. The goal is to install and characterize
8x
334
Fri Sep 10 10:38:13 2010
Damien Gallop
16O3+ for DRAGON