| ID | Date | Author | Type | Category | Subject | Text |  | 
| 413 | Mon Jul 18 10:02:42 2011 | Damien Gallop |  |  | 24Mg+6 from MWS for DRAGON | Keerthi came in early this morning to set up OLIS for 24Mg delivery. HEBT tuning is
 in progress.
 |     | 
| 412 | Mon Jul 18 09:53:05 2011 | Damien Gallop |  |  | 4He from MCIS to HERACLES done Saturday and Sunday | Keerthi came in on Saturday morning and set up the Supernanogan source for 4He delivery.
 It looks like it went well. The original
 |  | 
| 411 | Fri Jul 15 10:30:11 2011 | Damien Gallop |  |  | 24/25Mg+1 from MWS for HERACLES on SEBT1 | 25Mg beam mostly sitting on FC6 now, as HERACLES takes RIB. Source was opened
 on Monday night to replace microwave window.
 |       | 
| 410 | Mon Jul 11 09:46:07 2011 | Damien Gallop |  |  | 24/25Mg+1 from MWS for HERACLES on SEBT1 | Well, the plasma electrode shorted again, and Keerthi came in on Saturday to tear down
 the MWS and clean it. Beam is steady as she
 |  | 
| 409 | Fri Jul  8 10:07:14 2011 | Damien Gallop |  |  | 24/25Mg+1 from MWS for HERACLES on SEBT1 | Beam on FC6 overnight and very stable.
 It grew overnight and continues to grow,
 | 8x   | 
| 408 | Thu Jul  7 10:40:27 2011 | Damien Gallop |  |  | 24/25Mg+1 from MWS Setup | Source conditioned nicely overnight at 55kV with a little RF power on. Source gases
 checked, final cage inspection. Ready to
 | 6x   | 
| 407 | Wed Jul  6 13:20:15 2011 | Damien Gallop |  |  | 24/25Mg+1 from MWS Setup | Source opened, and aluminum components removed. Magnesium components from previous
 run cleaned and installed. Pumpdown in progress.
 |    | 
| 406 | Wed Jul  6 09:56:45 2011 | Damien Gallop |  |  | 27Al+1 from MWS for DRAGON EOB | DRAGON has been taking beam since approximately noon on Monday, and finished a little while
 ago. Feedback I have received is that beam
 | 13x   | 
| 405 | Sun Jul  3 09:56:47 2011 | Damien Gallop |  |  | 27Al+1 from MWS Setup | A lot has happened since the last entry. The source blinked out at some point. Cause
 cited was a PE short. Actions were taken,
 |       | 
| 404 | Thu Jun 30 10:02:08 2011 | Damien Gallop |  |  | 27Al+1 from MWS Setup | Source pumped overnight to previous baseline (red trace on attached Stripchart). IOPS
 conditioned it up to 42kV without a hitch.
 |      | 
| 403 | Wed Jun 29 15:49:16 2011 | Damien Gallop |  |  | 27Al+1 from MWS Setup | Switchover from 58Ni+1/MCIS to 27Al+1/MWS began just after noon. MWS cleaned and fitted
 with aluminum liners. Pumping in progress.
 |   | 
| 402 | Wed Jun 29 09:45:50 2011 | Damien Gallop |  |  | 58Ni from MCIS to TITAN | Last hours and minutes. Going well. Documentation appended. Users have requested beam until
 noon.
 | 8x   | 
| 401 | Tue Jun 28 09:32:09 2011 | Damien Gallop |  |  | 58Ni from MCIS to TITAN | Beam mostly idle overnight. Things are resuming now.
 |   | 
| 400 | Mon Jun 27 10:20:41 2011 | Damien Gallop |  |  | 58Ni from MCIS to TITAN | From MCIS. It looks like things went fairly well over the weekend for them. An interlock
 glitch on MCIS:IV1 this morning, source pressure
 |    | 
| 399 | Fri Jun 24 15:11:20 2011 | Damien Gallop |  |  | 58Ni from MCIS to FC6 Setup | OLIS was switched from 22Ne2+ (MWS) to 58Ni+1 (MCIS). Works like magic. 100epA presently.
 |  | 
| 398 | Fri Jun 10 11:35:24 2011 | Damien Gallop |  |  | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Beam sitting on FC6. Mel returned two flow controllers
 today, borrowed in March
 |  | 
| 397 | Thu Jun  9 16:51:09 2011 | Damien Gallop |  |  | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Note: A/q display is white. Possible culprit: IOSIOC. ICR will reboot
 it at first convenient opportunity.
 |       | 
| 396 | Mon May 30 14:44:01 2011 | Damien Gallop |  |  | 22Ne2+ for ICR Training | MWS online. Separator magstab program offline. Check: Kepco is switched off and one lead
 is physically cut and taped over. That's
 |   | 
| 395 | Mon May  2 10:50:28 2011 | Damien Gallop |  |  | Alkalis for DRAGON EOB | DRAGON has been taking various species of Na and Rb using the MWS. Run ended this
 morning. Emittance scan of 23Na attached.
 | 7x   | 
| 394 | Fri Apr  1 17:02:09 2011 | Damien Gallop |  |  | 12C2+ for Startup | Supernanogan is online with a bit of 12C2+ beam on FC6. Mag stability program is running.
 Source development to follow.
 |  |