  41   Thu Jul 2 16:55:04 2009 Damien GallopRoutineGeneralRF frequency scans versus each charge state of 16OLet's take a look at varying frequency
versus beam current for 16O2+. Starting RF
values shown below. FC6 = 1.09enA.
 7x 
  42   Fri Jul 3 10:03:11 2009 Damien GallopRoutineGeneralOvernight beam stability on FC3Here are some pics and data from total
MCIS beam on FC3 overnight. A bit inconclusive,
but there may be a temperature correlation.
 grab.lB3687.pnggrab.w13197.pngmcis_fc3_090703.datiosfc3_fc6_halltemp.txt 
  43   Fri Jul 3 10:29:15 2009 Damien GallopRoutineGeneralRF frequency scans versus each charge state of 16O cont'd.16O2+ beam on FC6 = 10nA as before. Move
to 16O3+ A/q = 5.33...
A frequency scan between 13 &
 grab.Cr7150.pnggrab.yi7257.pnggrab.vt7264.pnggrab.vP7271.png 
  44   Mon Jul 6 10:57:08 2009 Damien GallopRoutineGeneralBeam stability versus temperature over weekendWe had 16O3+ on FC6 on Friday. An IOSIOC
reboot occurred mid-afternoon Friday unfortunately.
Operators restored beam at about 06:00 on
 Picture_4.png 
  45   Mon Jul 6 17:34:24 2009 Damien GallopRoutineGeneral18O background studiesWell... my browser blew away just before
I submitted version one of this entry. Let's
try again.
 6x 
  46   Tue Jul 7 15:43:19 2009 Damien GallopRoutineGeneralISIS emittance rig tests this morningKeerthi and I were front and centre doing
ISIS emittance rig testing this morning.
He ran it, and I tried to find ways to run
 Picture_11.pngPicture_12.png 
  47   Tue Jul 7 17:47:14 2009 Damien GallopRoutineGeneral18On+ beam & emittanceAs noted earlier, we have 17O and 18O source
gas attached to the Supernanogan source chamber.
Both are valved off presently. The source
  
  48   Wed Jul 8 09:22:07 2009 Damien GallopRoutineGeneral18O4+ beam growth overnightAfter accessing the OLIS cage and opening
the 18O source gas valve, I restarted the
Supernanogan source last evening around 18:00
 grab.hD1461.png 
  49   Wed Jul 8 09:34:58 2009 Damien GallopRoutineGeneral18O4+ frequency optimizationStarting frequency: 15.7864GHz => 870pA
on FC6  Step size: 1MHz. Selected peaks
shown. There were many smaller resonances
  
  50   Wed Jul 8 10:57:46 2009 Damien GallopRoutineGeneral18O4+ emittance scansTune saved as 090708_1200.snapmcisfc6.
I settled on the 15.486GHz optimal frequency,
and tweaked that for effect. Then I ran a
 10x 
  51   Wed Jul 8 11:52:54 2009 Damien GallopRoutineGeneralSupernanogan development run plan for the remainder of this set* 18On+ emittance scans at present ion
source settings: complete today.
* 18On+ frequency measurements: Thursday.
  
  52   Wed Jul 8 16:12:51 2009 Damien GallopRoutineGeneralMass scan in progressA mass scan from A/q of zero to 25 is in
progress. Data file (large): masscorr_mcis_090708.txt.
The source is optimized for 18O4+. Fishing
 grab.rh2790.pngPicture_16.pngPicture_17.png 
  53   Wed Jul 8 17:47:26 2009 Damien GallopRoutineGeneral18O4+ emittance scansFirst up is a check scan of 18O4+. There
is a definite vertical offset compared to
earlier today. Otherwise, it correlates well
 grab.Jj2874.pnggrab.fz2878.pnggrab.ND2931.pnggrab.pH2935.pnggrab.oY2939.png 
  54   Wed Jul 8 17:58:02 2009 Damien GallopRoutineGeneral18O1+ emittance scanHere we go. A/q = 18 FC6 = 141.0nA MB =
2078G @ 130.2A
 grab.QR2996.pnggrab.dm3000.png 
  55   Wed Jul 8 18:12:25 2009 Damien GallopRoutineGeneral18O2+ emittance scanA/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A  grab.LL3034.pnggrab.Yj3038.png 
  56   Wed Jul 8 18:20:43 2009 Damien GallopRoutineGeneral18O3+ emittance scanA/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A  grab.Pc3095.pnggrab.Oi3099.png 
  57   Wed Jul 8 18:38:21 2009 Damien GallopRoutineGeneral18O4+ emittance scanA/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A  grab.Cb3157.pnggrab.wO3161.png 
  58   Wed Jul 8 18:47:43 2009 Damien GallopRoutineGeneral18O5+ emittance scanA/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A  grab.IW3188.pnggrab.kW3192.png 
  59   Wed Jul 8 18:57:09 2009 Damien GallopRoutineGeneral18O6+ emittance scanA/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A  grab.cb3228.pnggrab.un3232.png 
  60   Wed Jul 8 19:07:15 2009 Damien GallopRoutineGeneral18O7+ emittance scanA/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance
scan.
 grab.ca3306.png 