41
Thu Jul 2 16:55:04 2009
Damien Gallop
Routine
General
RF frequency scans versus each charge state of 16O
Let's take a look at varying frequency
versus beam current for 16O2+. Starting RF
values shown below. FC6 = 1.09enA.
7x
28
Mon Jun 22 20:28:37 2009
Damien Gallop
Routine
General
Preparations for 16O2+ delivery
In anticipation of 16O2+ delivery mid-week,
we checked 16O2+ production from the Supernanogan
source. No problem. We did have to use the
6x
173
Wed Oct 28 09:55:28 2009
Damien Gallop
Planned IOSIOC reboot
Controls is rebooting IOSIOC. I have inserted
MCIS:FC1 for the duration. Let's see what
comes of it all.
42
Fri Jul 3 10:03:11 2009
Damien Gallop
Routine
General
Overnight beam stability on FC3
Here are some pics and data from total
MCIS beam on FC3 overnight. A bit inconclusive,
but there may be a temperature correlation.
479
Fri May 16 08:44:27 2014
Raymond Dubé
Routine
General
OLIS work next week
Attached
is the scheduled work for OLIS next week.
230
Thu Mar 11 23:02:18 2010
Keerthi
OLIS status after shutdown
Microwave source is up and running.
Supernanogan: grounding rod is stuck,
RF generator does not clear the interlocks
150
Sun Oct 4 19:16:46 2009
Keerthi
OLIS status
Supernanogan is ready with 22Ne+4 for upcoming
CSB run. EL, HV and RF are on. The anlyzing magnet
and the other optics are set for A/Q=5.5.
164
Thu Oct 15 21:06:10 2009
Keerthi
OLIS status
33S development is completed. A 3nA
of 33S+5 can be produced with 10W of RF power
and 2.5mm aperture.
264
Fri May 7 19:10:05 2010
Keerthi Jayamanna
Routine
General
OLIS status
MW source is back and running.
A new vacuum
chamber is added to the Supernanogan RF block.
SO2
is not filled in yet.
387
Wed Feb 23 22:29:48 2011
Keerthi Jayamanna
OLIS mahnet
Klixon at the OLIS bemding magnet is not
funtioning properly.
220
Wed Jan 13 18:16:22 2010
Damien Gallop
OLIS development with MWS at 28keV
We will be delivering a 28keV beam to the
tuning boys tomorrow for further diagnosis
of the 8pi line. In anticipation, I restarted
6x
188
Wed Nov 18 23:46:14 2009
Keerthi Jayamanna
OLIS development started
All turbos in the OLIS and MCIS are off.
No controls for the MCIS. Pumps switched
of by pulling the CG cable.
209
Thu Dec 10 08:59:05 2009
Damien Gallop
OLIS development for CUSP source continued
Source stayed up quietly overnight. Current
dropped off gradually. I will tweak things
shortly.
210
Fri Dec 11 18:03:30 2009
Damien Gallop
OLIS development for CUSP source continued
Today we swapped power supplies between
the arc and plasma electrode. This gives
us a higher voltage range on the arc, at
212
Tue Dec 15 17:50:38 2009
Damien Gallop
OLIS development for CUSP source continued
Four larger apertures were installed yesterday.
This morning we fired up the modified source.
It lit immediately. Plenty of beam. Development
213
Wed Dec 16 14:07:37 2009
Damien Gallop
OLIS development for CUSP source continued
Today we vary source gas pressure.
Later... Several iterations of pressure,
tuning and standing on our heads. Representative
214
Fri Dec 18 13:14:01 2009
Damien Gallop
OLIS development for CUSP source continued
Yesterday: Busy! Source filment changed
last night. Source pumped overnight. First
start this morning.
9x
206
Mon Dec 7 09:48:24 2009
Damien Gallop
OLIS development for CUSP source continued
The OLIS cage was open over the weekend.
IOS pressure is in the 4e-7 range, with source
gas manifold closed and external helium bottle
207
Tue Dec 8 12:40:17 2009
Damien Gallop
OLIS development for CUSP source continued
Fuse for FUG power supply obtained and
installed. Source is up and warming up. ~100enA
on FC6.
208
Wed Dec 9 10:24:45 2009
Damien Gallop
OLIS development for CUSP source continued
CUSP source was off for the night, following
Keerthi's development. He had increased the
current on FC6 and the arc current substantially.