OLIS Logbook
General
General, Page 20 of 26
Not logged in
List
|
Find
|
Select
|
Import
|
Login
|
Help
Full
| Summary |
Threaded
513 Entries
Goto page
Previous
1
,
2
,
3
...
19
, 20,
21
...
24
,
25
,
26
Next
ID
Date
Author
Type
Category
Subject
Text
75
Wed Jul 15 10:51:25 2009
Damien Gallop
18O7+ survey
A/q = 2.571 Field = 752.9 FC6 = 88pA
85
Thu Jul 16 14:50:38 2009
Damien Gallop
18O7+ survey
A/q = 2.5714 Field = 751.1G FC6 = 40epA
No emittance scan possible.
102
Fri Jul 17 10:28:09 2009
Damien Gallop
18O7+ recheck
A/q = 2.571 Field = 753.5 FC6 = 50epA
60
Wed Jul 8 19:07:15 2009
Damien Gallop
Routine
General
18O7+ emittance scan
A/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance
scan.
76
Wed Jul 15 10:52:25 2009
Damien Gallop
18O6+ survey
A/q = 3 Field = 813.2 FC6 = 2.9nA
Beam is too faint for a good emittance
scan, but it's visible. Redo with reverse
7x
87
Thu Jul 16 15:22:51 2009
Damien Gallop
18O6+ survey
A/q = 3 Field = 811.2G FC6 = 1.6nA
Not quite enough beam for an emittance
scan.
101
Fri Jul 17 10:03:07 2009
Damien Gallop
18O6+ recheck
A/q = 3 Field = 813.9G FC6 = 2.2enA
I tweaked the adjustment of the displayed
A/q calibration to fit this one.
59
Wed Jul 8 18:57:09 2009
Damien Gallop
Routine
General
18O6+ emittance scan
A/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A
77
Wed Jul 15 14:41:25 2009
Damien Gallop
18O5+ survey
A/q = 3.6 Field = 888.6G FC6 = 10nA
Two emittance scans, one with the
as-is emittance rig, one with a manually
89
Thu Jul 16 15:41:35 2009
Damien Gallop
18O5+ survey
A/q = 3.6 Field = 888.6G FC6 = 6.2enA
58
Wed Jul 8 18:47:43 2009
Damien Gallop
Routine
General
18O5+ emittance scan
A/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A
4
Thu May 21 16:23:37 2009
Damien Gallop
Routine
General
18O4+/8+ to TUDA-II declared done around noon
End of run diagnostics done. See ISAC elog.
Supernanogan cart is already installed and
at high vacuum. Prepare to run 17O from Sgan
67
Mon Jul 13 09:49:52 2009
Damien Gallop
18O4+ tuning to TIGRESS today
As per our agreed deal last week, today
is reserved for Supernanogan tuning to TIGRESS.
Development will resume tomorrow.
70
Tue Jul 14 09:47:14 2009
Damien Gallop
18O4+ tuning to TIGRESS this morning
We have a change of schedule. Due to circumstances,
Sophia will continue tuning to TIGRESS this
morning. Sgan Development will resume this
7x
81
Thu Jul 16 14:25:27 2009
Damien Gallop
18O4+ survey
A/q = 4.5 Field = 993.5G FC6 = 24.0enA
91
Thu Jul 16 15:58:53 2009
Damien Gallop
18O4+ survey
A/q = 4.5 Field = 993.5G FC6 = 20enA
107
Mon Jul 20 09:25:35 2009
Damien Gallop
18O4+ run to TIGRESS complete
The 18O4+ run at about 5MeV/u ended this
morning with reasonable success, I'm informed,
despite MCIS vacuum trips, SC cryo trips
73
Wed Jul 15 10:27:18 2009
Damien Gallop
18O4+ overnight and emittance check
Repeat emittance scan of present 18O4+
beam. It compares okay (somewhat broader
emittance numbers) with yesterday's
49
Wed Jul 8 09:34:58 2009
Damien Gallop
Routine
General
18O4+ frequency optimization
Starting frequency: 15.7864GHz => 870pA
on FC6 Step size: 1MHz. Selected peaks
shown. There were many smaller resonances
50
Wed Jul 8 10:57:46 2009
Damien Gallop
Routine
General
18O4+ emittance scans
Tune saved as 090708_1200.snapmcisfc6.
I settled on the 15.486GHz optimal frequency,
and tweaked that for effect. Then I ran a
10x
Goto page
Previous
1
,
2
,
3
...
19
, 20,
21
...
24
,
25
,
26
Next
ELOG V2.9.2-2455