OLIS Logbook General
  General, Page 19 of 26  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Datedown Author Type Category Subject Text Attachments
  153   Wed Oct 7 16:54:33 2009 Keerthi   Today Supernanogan vacuum found to be down in
the morning. Restarted easily.
  
  152   Tue Oct 6 15:28:31 2009 Keerthi  OLIS A/Q changed to 5 (20Ne+4)Changed OLIS A/Q to 5 (20Ne+4) to satisfy
the CSB and ISAC development changes. 8nA
is sitting at the FC6
  
  151   Tue Oct 6 15:22:43 2009 Damien Gallop  22Ne4+ & 20Ne4+ operationOver the weekend, Keerthi had set up 22Ne4+
to FC6 for the purpose of developing a tune
matched with a similar tune from the CSB.
 20Ne4_on_FC6.png 
  150   Sun Oct 4 19:16:46 2009 Keerthi  OLIS statusSupernanogan is ready with 22Ne+4 for upcoming
CSB run. EL, HV and RF are on. The anlyzing magnet
and the other optics are set for A/Q=5.5.
  
  149   Fri Oct 2 15:58:36 2009 Keerthi  17O and Ne gases are now connectedA  1e-5 atm.cc/sec of 17O leak and
a 1e-6 atm.cc/sec of neon leak are connected
to the source through center tube of the
  
  148   Fri Oct 2 09:38:26 2009 KeerthiRoutineGeneral33Sulfur development completed successfully. 
Sulfur-33
development completed successfully.
  
  147   Wed Sep 30 15:30:04 2009 Damien Gallop  33S6+ from MCIS for DRAGON setupBeam is stable enough to let Marco set
up something to DRAGON. We are a couple of
days early.
 grab.sA3956.pnggrab.ar3960.png 
  146   Mon Sep 28 14:16:47 2009 Damien Gallop  MCIS Cart down for TP1 ReplacementWe are taking the opportunity to replace
TP1 today. Edi Dalla Valle is on it. Also,
Diagnostics has a WP in the queue for looking
  
  145   Mon Sep 28 14:12:17 2009 Damien Gallop  33S5+ from MCIS on Friday 25-Sep-2009A sustained 33S5+ beam was generated in
the Supernanogan on Friday, September 25th.
Attached is a trar plot.
 33S_from_MCIS_25-Sep-2009.png 
  144   Wed Sep 16 18:14:29 2009 Damien Gallop  Test scans for publication 2090916_1206ILTEMIT.txt
Graphics with "color" in
the filename will look in print the same
 19x 
  143   Wed Sep 16 12:48:13 2009 Keerthi  17O+5 double peaks090916_1242ILTEMIT.txt  17O+5 has
two peaks.
090916_1355ILTEMIT.txt  Repeat
 grab.U24653.pnggrab.s24670.pnggrab.s24675.pnggrab.d24681.pnggrab.u24686.png 
  142   Wed Sep 16 12:26:51 2009 KeerthiRoutineGeneral17O+3 emittance with changed steering090916_1222ILTEMIT.txt  Changed the
MCIS steering to center the beam in the EL.
17O+3 ~5uA, 50x100
  
  141   Wed Sep 16 12:20:10 2009 Keerthi  17O+3 emittance with increased EL090916_1215ILTEMIT.txt   
EL increased, ~4.5uA, emittance increases,
50x100   17O+3
  
  140   Wed Sep 16 12:12:04 2009 KeerthiRoutineGeneral17O+3 emittance sacns090916_1156ILTEMIT.txt     
17O+3  good settings 50x100 ,  
333nA Scale, ~4uA
  
  139   Tue Sep 15 20:02:46 2009 Keerthi  17O8+ on FC6 from MCIS0.4nA of 17O+8 is sitting on FC6. Development
will continue tomorrow.
 grab.I24583.png 
  138   Tue Sep 15 19:46:21 2009 KeerthiRoutineGeneralSupernanogan emittance scans090915_1915ILTEMIT.txt = 17O +3,  4.4uA
new tune, scanner offset +10V,  scanner
scale 100nA , 100x50 matrix
 9x 
  137   Tue Sep 15 16:56:03 2009 Damien Gallop  Test scans for publicationHere are pix of the same scan: original,
then greyscale, then cropped, using The GIMP.
Not bad.
 grab.E19994.pnggrab.U19879-greyscale.pnggrab.U19879-cropped.png 
  136   Tue Sep 15 16:09:31 2009 Damien Gallop  MCIS Development 17O emittance scansWe noticed a double peak effect in the
16O3+ scan. I will set up the line for 17O3+
and see.
 13x 
  135   Tue Sep 15 10:32:39 2009 Damien Gallop  MCIS DevelopmentSo. We are preparing for a few days of
Supernanogan development. The present run
plan is to obtain good emittance scans for
 7x 
  134   Tue Sep 15 09:54:22 2009 Damien Gallop  16O3+ run to DRAGON ended on schedule at 08:00The DRAGON run ended uneventfully. (That's
a good thing.) I ran a few emittance scans
on the beam as-is. It is clearly monoisotopic.
 8x 
ELOG V2.9.2-2455