| ID | 
Date | 
Author | 
Type | 
Category | 
Subject | 
Text | 
  | 
| 
  153  
 | 
Wed Oct  7 16:54:33 2009 | 
Keerthi |   |   |   | Today Supernanogan vacuum found to be down in 
the morning. Restarted easily. | 
   | 
| 
  152  
 | 
Tue Oct  6 15:28:31 2009 | 
Keerthi |   |   | OLIS A/Q changed to 5 (20Ne+4) | Changed OLIS A/Q to 5 (20Ne+4) to satisfy 
the CSB and ISAC development changes. 8nA 
is sitting at the FC6 | 
   | 
| 
  151  
 | 
Tue Oct  6 15:22:43 2009 | 
Damien Gallop |   |   | 22Ne4+ & 20Ne4+ operation | Over the weekend, Keerthi had set up 22Ne4+ 
to FC6 for the purpose of developing a tune 
matched with a similar tune from the CSB. | 
    | 
| 
  150  
 | 
Sun Oct  4 19:16:46 2009 | 
Keerthi |   |   | OLIS status | Supernanogan is ready with 22Ne+4 for upcoming 
CSB run. EL, HV and RF are on. The anlyzing magnet 
and the other optics are set for A/Q=5.5. | 
   | 
| 
  149  
 | 
Fri Oct  2 15:58:36 2009 | 
Keerthi |   |   | 17O and Ne gases are now connected | A  1e-5 atm.cc/sec of 17O leak and 
a 1e-6 atm.cc/sec of neon leak are connected 
to the source through center tube of the | 
   | 
| 
  148  
 | 
Fri Oct  2 09:38:26 2009 | 
Keerthi | Routine | General | 33Sulfur development completed successfully. |  
 
Sulfur-33 
development completed successfully.
 
 | 
   | 
| 
  147  
 | 
Wed Sep 30 15:30:04 2009 | 
Damien Gallop |   |   | 33S6+ from MCIS for DRAGON setup | Beam is stable enough to let Marco set 
up something to DRAGON. We are a couple of 
days early. | 
     | 
| 
  146  
 | 
Mon Sep 28 14:16:47 2009 | 
Damien Gallop |   |   | MCIS Cart down for TP1 Replacement | We are taking the opportunity to replace 
TP1 today. Edi Dalla Valle is on it. Also, 
Diagnostics has a WP in the queue for looking | 
   | 
| 
  145  
 | 
Mon Sep 28 14:12:17 2009 | 
Damien Gallop |   |   | 33S5+ from MCIS on Friday 25-Sep-2009 | A sustained 33S5+ beam was generated in 
the Supernanogan on Friday, September 25th. 
Attached is a trar plot. | 
    | 
| 
  144  
 | 
Wed Sep 16 18:14:29 2009 | 
Damien Gallop |   |   | Test scans for publication 2 | 090916_1206ILTEMIT.txt
 
Graphics with "color" in 
the filename will look in print the same | 
 19x   | 
| 
  143  
 | 
Wed Sep 16 12:48:13 2009 | 
Keerthi |   |   | 17O+5 double peaks | 090916_1242ILTEMIT.txt  17O+5 has 
two peaks.
 
090916_1355ILTEMIT.txt  Repeat | 
        | 
| 
  142  
 | 
Wed Sep 16 12:26:51 2009 | 
Keerthi | Routine | General | 17O+3 emittance with changed steering | 090916_1222ILTEMIT.txt  Changed the 
MCIS steering to center the beam in the EL. 
17O+3 ~5uA, 50x100 | 
   | 
| 
  141  
 | 
Wed Sep 16 12:20:10 2009 | 
Keerthi |   |   | 17O+3 emittance with increased EL | 090916_1215ILTEMIT.txt    
EL increased, ~4.5uA, emittance increases, 
50x100   17O+3 | 
   | 
| 
  140  
 | 
Wed Sep 16 12:12:04 2009 | 
Keerthi | Routine | General | 17O+3 emittance sacns | 090916_1156ILTEMIT.txt      
17O+3  good settings 50x100 ,   
333nA Scale, ~4uA | 
   | 
| 
  139  
 | 
Tue Sep 15 20:02:46 2009 | 
Keerthi |   |   | 17O8+ on FC6 from MCIS | 0.4nA of 17O+8 is sitting on FC6. Development 
will continue tomorrow. | 
    | 
| 
  138  
 | 
Tue Sep 15 19:46:21 2009 | 
Keerthi | Routine | General | Supernanogan emittance scans | 090915_1915ILTEMIT.txt = 17O +3,  4.4uA 
new tune, scanner offset +10V,  scanner 
scale 100nA , 100x50 matrix | 
 9x   | 
| 
  137  
 | 
Tue Sep 15 16:56:03 2009 | 
Damien Gallop |   |   | Test scans for publication | Here are pix of the same scan: original, 
then greyscale, then cropped, using The GIMP. 
Not bad. | 
      | 
| 
  136  
 | 
Tue Sep 15 16:09:31 2009 | 
Damien Gallop |   |   | MCIS Development 17O emittance scans | We noticed a double peak effect in the 
16O3+ scan. I will set up the line for 17O3+ 
and see. | 
 13x   | 
| 
  135  
 | 
Tue Sep 15 10:32:39 2009 | 
Damien Gallop |   |   | MCIS Development | So. We are preparing for a few days of 
Supernanogan development. The present run 
plan is to obtain good emittance scans for | 
 7x   | 
| 
  134  
 | 
Tue Sep 15 09:54:22 2009 | 
Damien Gallop |   |   | 16O3+ run to DRAGON ended on schedule at 08:00 | The DRAGON run ended uneventfully. (That's 
a good thing.) I ran a few emittance scans 
on the beam as-is. It is clearly monoisotopic. | 
 8x   |