| ID | 
Date | 
Author | 
Type | 
Category | 
Subject | 
Text | 
  | 
| 
  273  
 | 
Tue May 18 09:15:16 2010 | 
Damien Gallop |   |   | 20Ne1+ at 40.8keV for TIGRESS setup | Prepare to switch beam from 22Ne2+ to 20Ne1+. 
Skimmers from 22Ne2+ run shown below. Table 
of tune options below. We will be using the | 
 8x   | 
| 
  272  
 | 
Tue May 18 09:03:32 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 EOB | EOB for SEBT1 run at 08:30, taking 11Li 
from ITE and 22Ne2+ from OLIS when needed. 
Attempted emittance scans last evening, but | 
      | 
| 
  271  
 | 
Mon May 17 09:09:50 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Last day of this pilot beam to TUDA-II. 
Expect a beam switch tomorrow for sake of 
TIGRESS. | 
    | 
| 
  270  
 | 
Fri May 14 08:50:56 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | MWS continues to provide 22Ne2+ for pilot 
beam use. Beam quietly sitting on FC6. Stripchart 
attached. Also, Supernanogan plasma is on | 
    | 
| 
  269  
 | 
Thu May 13 09:25:38 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Beam continues to be reserved for E1147 
pilot beam use. Beam was nice and stable 
overnight, as expected. Beam (blue) followed | 
     | 
| 
  268  
 | 
Wed May 12 13:40:01 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Back to pilot beam status as of around 
18:00 last night. A couple of sideshows through 
the evening. ICR made an elog entry about | 
     | 
| 
  267  
 | 
Tue May 11 08:55:41 2010 | 
Damien Gallop |   |   | Supernanogan development | Leak checking on the Supernanogan continues 
today. We are preparing for an up-coming 
33S run, for which we want "perfect" | 
       | 
| 
  266  
 | 
Mon May 10 16:42:55 2010 | 
Damien Gallop |   |   | Supernanogan development | By agreement, the source came down this 
morning for continuing Supernanogan development. 
Main event: leak detecting. | 
   | 
| 
  265  
 | 
Mon May 10 09:39:34 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Supernanogan development, mainly for the 
sake of the upcoming 33S run, took place 
for a little while on Friday. It was expected | 
    | 
| 
  264  
 | 
Fri May  7 19:10:05 2010 | 
Keerthi Jayamanna | Routine | General | OLIS status | MW source is back and running.
 
A new vacuum 
chamber is added to the Supernanogan RF block.
 
SO2 
is not filled in yet. | 
   | 
| 
  263  
 | 
Fri May  7 12:29:41 2010 | 
Keerthi Jayamanna |   |   | Supernanogan development | Supernanogan development for 33S started. 
All MW and MW and MCIS power sypplies are 
off. | 
   | 
| 
  262  
 | 
Thu May  6 14:33:07 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Beam from MWS remains quietly sitting on 
FC6, on standby for pilot beam use to SEBT1. 
The cyclotron is still down with cryogenerator | 
    | 
| 
  261  
 | 
Wed May  5 09:46:40 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Beam on standby for pilot beam. Cyclotron 
is still down with vacuum troubles since 
~03:00, so no RIB to ISAC. | 
   | 
| 
  260  
 | 
Tue May  4 14:19:18 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Beam from MWS continues for pilot beam 
use into SEBT1. There are cyclotron issues 
with cryogenics, so 11Li delivery from ITE | 
   | 
| 
  259  
 | 
Mon May  3 18:12:12 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Beam was switched on Friday morning from 
16O1+ to 22Ne2+. This time it's a pilot beam 
for a 11Li experiment. | 
   | 
| 
  258  
 | 
Fri Apr 30 13:02:17 2010 | 
Damien Gallop |   |   | 22Ne2+ at 22.44keV for SEBT1 | Mid-morning the source was switched over 
from 16O1+ to 22Ne2+ operation for a new 
experiment. OLIS will be used as the pilot | 
   | 
| 
  257  
 | 
Fri Apr 30 12:58:21 2010 | 
Damien Gallop |   |   | 16O1+ at 32.64keV to SEBT2 | Delivery to S1151 went quietly overnight 
for their last few hours. The run ended at 
~08:30 as scheduled. Marco and ICR did some | 
      | 
| 
  256  
 | 
Thu Apr 29 09:11:27 2010 | 
Damien Gallop |   |   | 16O1+ at 32.64keV to SEBT2 | Another quiet night of beam to S1151. | 
    | 
| 
  255  
 | 
Wed Apr 28 10:08:05 2010 | 
Damien Gallop |   |   | 16O1+ at 32.64keV to SEBT2 | Beam delivery continued nicely through 
the night.
 
Yesterday Controls repaired and reinstalled | 
    | 
| 
  254  
 | 
Tue Apr 27 09:04:13 2010 | 
Damien Gallop |   |   | 16O1+ at 32.64keV to SEBT2 | Nominal beam operation to SEBT2 overnight. 
A chart of beam over the last few days is 
attached. There is a step change in the separator | 
      |