OLIS Logbook General
  General, Page 13 of 26  Not logged in ELOG logo
  ID Date Author Type Category Subject Text Attachments
  273   Tue May 18 09:15:16 2010 Damien Gallop  20Ne1+ at 40.8keV for TIGRESS setupPrepare to switch beam from 22Ne2+ to 20Ne1+.
Skimmers from 22Ne2+ run shown below. Table
of tune options below. We will be using the
 8x 
  272   Tue May 18 09:03:32 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1 EOBEOB for SEBT1 run at 08:30, taking 11Li
from ITE and 22Ne2+ from OLIS when needed.
Attempted emittance scans last evening, but
 Picture_6.pngPicture_7.pngPicture_8.png 
  271   Mon May 17 09:09:50 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Last day of this pilot beam to TUDA-II.
Expect a beam switch tomorrow for sake of
TIGRESS.
 Picture_6.png 
  270   Fri May 14 08:50:56 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1MWS continues to provide 22Ne2+ for pilot
beam use. Beam quietly sitting on FC6. Stripchart
attached. Also, Supernanogan plasma is on
 Picture_5.png 
  269   Thu May 13 09:25:38 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Beam continues to be reserved for E1147
pilot beam use. Beam was nice and stable
overnight, as expected. Beam (blue) followed
 Picture_1.pngPicture_2.png 
  268   Wed May 12 13:40:01 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Back to pilot beam status as of around
18:00 last night. A couple of sideshows through
the evening. ICR made an elog entry about
 Picture_2.pngPicture_1.png 
  267   Tue May 11 08:55:41 2010 Damien Gallop  Supernanogan developmentLeak checking on the Supernanogan continues
today. We are preparing for an up-coming
33S run, for which we want "perfect"
 grab.tg1846.pnggrab.bE1993.pnggrab.ed2041.pnggrab.or2050.png 
  266   Mon May 10 16:42:55 2010 Damien Gallop  Supernanogan developmentBy agreement, the source came down this
morning for continuing Supernanogan development.
Main event: leak detecting.
  
  265   Mon May 10 09:39:34 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Supernanogan development, mainly for the
sake of the upcoming 33S run, took place
for a little while on Friday. It was expected
 Picture_1.png 
  264   Fri May 7 19:10:05 2010 Keerthi JayamannaRoutineGeneralOLIS statusMW source is back and running.
A new vacuum
chamber is added to the Supernanogan RF block.
SO2
is not filled in yet.
  
  263   Fri May 7 12:29:41 2010 Keerthi Jayamanna  Supernanogan developmentSupernanogan development for 33S started.
All MW and MW and MCIS power sypplies are
off.
  
  262   Thu May 6 14:33:07 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Beam from MWS remains quietly sitting on
FC6, on standby for pilot beam use to SEBT1.
The cyclotron is still down with cryogenerator
 Picture_1.png 
  261   Wed May 5 09:46:40 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Beam on standby for pilot beam. Cyclotron
is still down with vacuum troubles since
~03:00, so no RIB to ISAC.
  
  260   Tue May 4 14:19:18 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Beam from MWS continues for pilot beam
use into SEBT1. There are cyclotron issues
with cryogenics, so 11Li delivery from ITE
  
  259   Mon May 3 18:12:12 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Beam was switched on Friday morning from
16O1+ to 22Ne2+. This time it's a pilot beam
for a 11Li experiment.
  
  258   Fri Apr 30 13:02:17 2010 Damien Gallop  22Ne2+ at 22.44keV for SEBT1Mid-morning the source was switched over
from 16O1+ to 22Ne2+ operation for a new
experiment. OLIS will be used as the pilot
  
  257   Fri Apr 30 12:58:21 2010 Damien Gallop  16O1+ at 32.64keV to SEBT2Delivery to S1151 went quietly overnight
for their last few hours. The run ended at
~08:30 as scheduled. Marco and ICR did some
 grab.s30283.pnggrab.Y30291.pnggrab.z30299.png 
  256   Thu Apr 29 09:11:27 2010 Damien Gallop  16O1+ at 32.64keV to SEBT2Another quiet night of beam to S1151.  Picture_5.png 
  255   Wed Apr 28 10:08:05 2010 Damien Gallop  16O1+ at 32.64keV to SEBT2Beam delivery continued nicely through
the night.
Yesterday Controls repaired and reinstalled
 Picture_4.png 
  254   Tue Apr 27 09:04:13 2010 Damien Gallop  16O1+ at 32.64keV to SEBT2Nominal beam operation to SEBT2 overnight.
A chart of beam over the last few days is
attached. There is a step change in the separator
 Picture_1.pngPicture_3.pnggrab.NQ9764.png 
ELOG V2.9.2-2455