ID |
Date |
Author |
Type |
Category |
Subject |
381
|
Tue Dec 21 09:43:22 2010 |
Damien Gallop | | | In Memoriam... Mike McDonald |
At 5:00 this morning, after a lengthy battle with cancer, Mike passed from this life to his eternal reward. He has left us a great legacy. May he rest in peace. |
46
|
Tue Jul 7 15:43:19 2009 |
Damien Gallop | Routine | General | ISIS emittance rig tests this morning |
Keerthi and I were front and centre doing ISIS emittance rig testing this morning. He ran it, and I tried to find ways to run the data in Matlab afterwards. Main limitation up there at the ISIS Console is lack of any ssh-enabled terminals. Keerthi's wireless laptop is okay, but this stuff pushes the poor little thing to the edge. Plus, there were some X display issues on it. He has Matlab installed locally, but it takes a bit of a rocket scientist to run it, and once you do get it going, Matlab complains that the data file format is incorrect. We believe it's a matter of line endings: Windows versus the rest of the unix/Linux/Mac/VMS world. So it goes. All in all, a successful morning. There is enough data to think about how it all works, and we have a couple of hours of R&D again tomorrow morning before production beam. I'll put in a few emittance panels here in a while. Keep in mind that these are with beams on the order of mA, not nA!
DataFile Pulser Arc 90% 86% 63% cut% #71 #72 111 112 113 30 nor. Emit.
95152 5% 6A 4.01 3.51 1.91 1% 0 4k 4k 0.101
102032 10% 6A 1.59 4.02 2.1 1% 0 4k 4k 0.116
102904 20% 6A 4.89 4.29 2.21 1% 0 4k 4k 0.122
103602 30% 6A 5.18 5.11 2.7 1% 0 4k 4k 0.131
105650 40% 6A 1% 0 4k 4k
60% 6A 1% 0 4k 4k
115852 70% 6A 6.21 5.56 3.07 1% 0 4k 4k 0.157
120728 70% 6A 6.07 5.41 3 1% 2159 0 4k 4k 0.154
122216 70% 6A 5.96 5.32 2.94 1% 2247 0 4k 4k 0.151
123149 70% 7A (no tuning) 1% 2247 0 4k 4k 0.147
124609 60% 7A (bit of tuning) 1% all tuned all tuned
Meanwhile, OLIS and the Supernanogan were off overnight in preparation for transformer tap selection for the sake of the CSB. See WP#2009-07-07-7 for more details.Turbos were turned off in preparation for attaching 17O and 18O source gases. Both are attached now, and valved off presently. I restarted the Supernanogan with about a nA of 18O2+ at FC6. Let it cook for a bit. |
473
|
Mon Dec 17 14:08:52 2012 |
Keerthi Jayamanna | | | IRIS beam delivary is completed |
IRIS beam delivery is completed with extra 3 days of beam providing to them.
18O2 and 40Ar+2 were delivered with few attenuators i place. |
174
|
Thu Oct 29 09:42:23 2009 |
Damien Gallop | | | IOSIOC work in progress |
Yesterday there was an IOSIOC reboot for a purpose. It was an opportunity to demonstrate to Controls that IOSIOC reboots materially affect the IOS section. Controls responded to an ICR fault report on it, and have not reported back to ICR so far. The source was off overnight and remains off now. I have informed ICR that if nothing happens this morning, I will restart the source after lunch.
Later... Jane reports that there was a problem, and it's been solved. We have to request that MCIS PVs get restored after a reboot. Done. Restart stuff. Much of IOS was already on. |
391
|
Wed Mar 9 11:09:02 2011 |
Keerthi Jayamanna | | | IOS:SSW failed |
IOS:SSW failed unexpectedly. No reason found. Came back on easily. |
231
|
Fri Mar 12 11:33:09 2010 |
Keerthi | | | IOS:IG! |
IOS:IG1 is faulty. Need to replac it during next earliest window. |
384
|
Fri Feb 18 11:43:32 2011 |
Keerthi Jayamanna | | | IOS: EE Status |
IOS:EE found damaged. It has been replaced with IOS:SSEE-Michael B. |
475
|
Wed Jan 22 10:34:58 2014 |
Raymond Dubé | | | IN-line 100K for IOS:YCB1A removed |
Last January 17th 2014 we removed an in-line resistor (100K 10W) from IOS:YCB1A because we do not think that it is needed.
|
218
|
Mon Jan 11 17:40:07 2010 |
Damien Gallop | | | Happy New Year! |
Welcome to 2010. Shutdown is underway across the site, while beam development is going on at OLIS. |
474
|
Mon Dec 17 14:10:22 2012 |
Keerthi Jayamanna | | | Gas flow controller fault |
Controls group may need some assistance from OLIS group in order to trouble shoot the problem. |
27
|
Mon Jun 22 16:00:04 2009 |
Damien Gallop | Routine | General | Emittance thoughts and other matters |
An emittance scan of the 16O7+ beam follows. Also, a stripchart of the same beam on FC6 overnight. Keerthi did some studies over the weekend. He found that the characteristics of the amplifiers behind FC6 and the emittance rig cup differ significantly. That's disconcerting. We did a visual this morning, and confirmed that the amplifiers are identical VME modules in the same crate. He believes it's a scaling thing. We will test again with a current source this afternoon.
Later... The apparent discrepancy between the two amplifiers was in fact a bad patch cable in the test setup. So that's solved. The two amplifiers differ in this way, that FC6 has the updated version with the middle gain ranges and auto-ranging, whereas the emittance cup does not. We will be asking Controls to update this amplifier to the now-ISAC standard. The test setup consisted mainly of a very high gain amplifier. Overall, the tests worked out pretty well, as you will see below in an emittance scan of 16O7+ done with the amplifier in the loop. The second emittance scan is 16O7+ and the highest EPICS gain setting, i.e. 1mA. Note that Matlab is unable to calculate an emittance here. The third emittance scan is the same beam at the next gain setting, i.e. 1uA. We just about make it, with only a relative handful of data points clipped, and Matlab calculates emittance easily. |
10
|
Mon Jun 8 09:31:39 2009 |
Damien Gallop | Routine | General | Emittance scan of 18O beam from MWS |
The TIGRESS run ended this morning. Supernanogan Development begins now for two weeks. Begin an 18O1+ emittance scan and also take some fast FC6 current measurements before we switch over. |
512
|
Wed Feb 22 21:46:27 2017 |
Keerthi Jayamanna | | | Elog is working now |
Elog is now functioning. We can start entering notes |
29
|
Tue Jun 23 10:33:43 2009 |
Damien Gallop | Routine | General | Effects of RF on charge state |
Today is the last day of this set of Supernanogan Development. The source ran at 16KV overnight, in anticipation of 16O2+ delivery later today. I expected more bias sparking, but it appears that it sparked off only once. So I will condition at a higher bias later today. Meanwhile, the operators reported touching up the tune with the magnet and the RF. Perhaps we are seeing some temperature effect on the source, so I will be looking at effects of RF on 16O7+ for the next while.
Effects of RF Parameters on 16O7+ Intensity
RF SP (GHz) |
Amplitude SP (dB) |
Power (W) |
FC6 (nA) |
Comments |
15.4726 |
11.10 |
25 |
0.83 |
Starting values optimized |
15.4306 |
11.10 |
27 |
1.9 |
RF tolerance feels wider |
15.3624 |
10.8 |
19 |
0.85 |
|
14.3579 |
10.8 |
40 |
0.85 |
|
15.846 |
11 |
22 |
0 .75 |
|
15.477 |
10.6 |
32 |
1.75 |
Narrow |
15.4290 |
11 |
24 |
2.85 |
Tuner adjustment lost all gains so far |
15.4330 |
10.8 |
27 |
2.85 |
Seems resilient enough |
15.438 |
11 |
35 |
2.5 |
15.433 - 15.443 range. This is the keeper. |
Below is a stripchart of the beam (in blue; turquise is RF power) for the last three hours, of which the last 150 minutes are at the present settings. Pretty good, I'd say. I double-checked the range on the RF, and it's exactly the same as the start. Excellent. To round things out, here is a last emittance scan of 16O7+ before we move to 16O2+. |
386
|
Tue Feb 22 18:54:43 2011 |
Keerthi Jayamanna | | | EE and SSEE |
Both EE and SSEE problems were solved. They are working OK now. |
232
|
Fri Mar 12 11:35:34 2010 |
Keerthi | | | Cusp water cooling |
Cusp source water cooling (#4) interlick does not work. |
194
|
Thu Nov 26 06:22:58 2009 |
Keerthi Jayamanna | | | Cusp source |
Arc power supply does not hold any voltage. |
393
|
Tue Mar 29 15:32:08 2011 |
Damien Gallop | | | Controls and Panel MRO |
Controls is working on an interlock issue. Electrical panel MCC-X maintenance is planned for tomorrow afternoon.
Loaned a Horiba SEC-7320 flow controller to Mel. This unit belongs to Friedhelm. |
39
|
Tue Jun 30 17:39:13 2009 |
Damien Gallop | Routine | General | Compare 16O2+ beam from start of run to today |
There seemed to be some small change to the beam over the week of TACTIC running. I would like to poke around a bit. The emittance plots suggest some vertical movement at least. The two plots are the before (emittance) and after (emittance). The two tune saves are 090624_0930.snapmcisfc6 and 090629_1730.snapmcisfc6 (present tune) respectively. Here is how they look juxtaposed. I restored the downstream elements. Let's see what that looks like in an emittance scan. They compare well! All changes in beam position can be completely attributed to tuning changes. End of story. I have restored the tune and centred up the emittance plots. Done. |
24
|
Thu Jun 18 09:38:52 2009 |
Damien Gallop | Routine | General | Check Supernanogan beam after IOC reboot yesterday |
As mentioned before, IOSIOC was rebooted yesterday afternoon to unfreeze the emittance rig panel. It cost us our tune, which unfortunately wasn't saved very well. Lesson learned: Save often. I will run a mass scan now and check the mass correlations calibration. Then I will pick up with some 16On+ emittance scans. Keerthi was here until late last night working with the beam also. He will have some results for sure.
The first emittance scan of the day is in, 16O1+ at 10:29.
The second emittance scan of the day is in, 16O2+ at 11:00.
Break for a mass scan to A/q=50. (Fire alarm in ISAC-II rang around 11:30.) Here is the first part. I have run the data in Gabe's Calibrate program and adjusted the two constants slightly. Looks very good. BTW there are some new artefacts in the mass correlation plot that weren't there before. They don't affect anything but the appearance of the plot. However, they do append a few lines of spurious data to the plot data file, which have to be expunged manually.
The third emittance scan: 16O2+ check at 13:08. Looks OK.
The fourth scan : 16O4+ and friends at 13:24.
The fifth scan: 16O5+ at 13:31. This one should be redone.
The sixth scan: 16O3+ at 13:39.
|