ID Date Author Operational Modedown Subject
  199   Thu May 31 07:11:05 2007 Doug PreddyQuench Recoveryswitched to parallel cold return
switched to parallel cold return earlier this morning. Vacuum is 5 x 10-5.
  200   Thu May 31 11:51:49 2007 Doug PreddyQuench RecoverySwitched to series mode
  202   Thu Jun 14 00:10:10 2007 Doug PreddyQuench Recoveryrecovering from earlier quench
Solenoid quenched on power lead temperature last night at about 6:00. I 
restarted flow to the solenoid in parallel cold return. Switched to series 
mode and am building liquid. 
  204   Tue Jun 19 21:15:41 2007 Doug PreddyQuench RecoveryToday's quench
power lead temps caused a quench at 8:30 this morning. Recovery of system 
and flow to solenoid was started by 11:00. Solenoid was switched to series 
cold at 3:00. Solenoid and power leads were cold at ~6:30. power supply 
was to be energized by experimenters.
  206   Wed Jul 4 11:13:12 2007 Doug PreddyQuench Recoverytest
This is a test to make sure the e-mail works.
  209   Sat Jul 28 15:45:17 2007 Doug PreddyQuench Recoveryquench recovery
The solenoid tripped off this morning due to pwer lead over temp. The 
compressor was also off. I restarted this morning at about 8:15 in 
parallel cold return. Switching to series mode at 3:40.
  210   Sat Jul 28 22:30:13 2007 Doug PreddyQuench Recoveryquench again
recovered system and energized solenoid at about 6:00 this evening.
At 9:30 power lead temps quenched solenoid again. MV52 stuck open during 
start-up.
  211   Sun Jul 29 04:58:27 2007 Doug PreddyQuench RecoveryEnergizing solenoid
LHe level~50%. Still have a slight ripple in the power leads, but they are 
cold enough to power the solenoid. LHe_in varies between 10.7K - 11.3K.
  213   Mon Aug 6 08:41:31 2007 Doug PreddyQuench RecoveryCold box trip at 6:00
compressor off due to cold box trip at 6:00 this morning. Restarted system 
and started flow to solenoid in parallel cold return.
  225   Fri Oct 5 10:25:43 2007 Doug PreddyQuench RecoveryUnknown quench 2
Kevin and I were at the Sulzer panel when the system quenched 2. No 
obvious reasons. Restarted the system.
  226   Fri Oct 5 13:25:41 2007 Doug PreddyQuench Recoveryfunny graph
There was a fluctuation of the positive lead temp with no flow going to 
the power leads.
Attachment 1: Capture.jpg
Capture.jpg
  227   Tue Oct 9 12:58:22 2007 Doug PreddyQuench RecoverySolenoid Quench 2
Refrigeration sytem shut off at ~ 12:30 today. No apparent reason. Only 
light on was a cold box fault. 
Restarted in parallel cold return mode.
  228   Tue Oct 9 13:16:44 2007 Doug PreddyQuench Recoveryswitched to series mode
  230   Thu Nov 8 09:28:53 2007 Doug PreddyQuench Recoverystarted compressor
And started flow to coldbox,solenoid in parallel warm return.


Tuesday evening theree was a 2 hour power outage 19:00- 21:00. No call 
made to M9 operator.
Wednesday tried to recover vacuum. Started cool down Thursday morning.
  231   Fri Nov 9 07:37:44 2007 Doug PreddyQuench Recoveryswitched to series mode
switched to series mode.
  232   Fri Nov 9 14:50:03 2007 Doug PreddyQuench RecoverySolenoid cold
Solenoid cold. Added two bottles of helium. Allowing to stablize. Will 
ramp power supply in half an hour.
  235   Mon Nov 19 02:58:44 2007 Doug PreddyQuench RecoverySolenoid quenched on power lead over temperature
I received a page at 1:30 this morning. The power lead temperatures were 
climbing. Cycling CV142 did not fix the problem. The solenoid quenched at 
1:50.
Restarted flow at 2:45 in parallel cold return.
  236   Mon Nov 19 04:30:47 2007 Doug PreddyQuench Recoveryswitched to series mode
  242   Mon Dec 3 14:59:58 2007 Doug PreddyQuench RecoveryNot really a quench recovery, But...
Not really a quench recovery, but...I wanted to send this out via e-mail. 
The contactor for the compressor building fan failed recently. Randy is 
looking after it, but parts will have to be ordered. The big door should 
stay open until the fan is running again. 
Other than the fan, the rest of the system weathered the weather okay. 
It's up and running until Wednesday morning. After maintenance day, we 
should ramp down the solenoid power supply and leave the refrigerator 
running. We can do some training and maintenance at this time. I would 
also like to keep it cold until blocks can be removed so we can pump out 
the cold box.
  251   Thu Jul 24 16:28:50 2008 Doug PreddyQuench Recoverypower bump
There was a power bump at ~15:00 today. All mseon hall cooling water went off. Compressor tripped. Main magnet went off. Restarted compressor after water pumps came back on. Started flow to the cold box. Compressor outlet pressure went >12 Bar and tripped of the compressor. Restarted again and am now cooling in parallel cold return. Solenoid ~25K.