  140   Thu Jul 20 13:21:57 2006 Willy AnderssonQuench Recoverystarted // warm return flow.TIC121 was down to 27K
warm return valves were wide open
opened supply valves CV143 and CV146.
  
  141   Thu Jul 20 13:27:21 2006 Willy AnderssonQuench Recoverycold return mode continues...cr_c1 and cr_12 are both at about 45K and
heading slowly down, so the 
gamble of going to // cold return worked.
  
  142   Thu Jul 20 13:34:26 2006 Willy AnderssonQuench Recoverycold return mode continues...Even though cr_c1 and cr_c12 have begun to
tick down, cr_c7 and cr_c6 are 
actually ticking up. This is probably a wave
  
  143   Fri Jul 21 07:39:37 2006 Doug PreddyQuench RecoveryCool down continuesRaised PIC229 to 11Bar. Started to close HIC155.
Cooling rates improve.
  
  144   Fri Jul 21 14:08:04 2006 Doug PreddyQuench Recoveryswitch to series modeCoils temps <10K.Switching to series mode.   
  145   Fri Jul 21 17:18:19 2006 Willy AnderssonQuench RecoveryOpened HIC142 fully openPower leads have flatlined but still building
LHe level.
  
  146   Fri Jul 21 23:36:21 2006 Doug PreddyQuench RecoveryFinal cooldown problems80K shield is down to <60K Liquid level not
building. Power leads rippling 
and warming. T1 inlet 85K with 10%heater
  
  147   Sat Jul 22 06:34:14 2006 ExperimentorQuench Recoverylooking goodDonald Arseneau reporting.

It is looking pretty good, so I came back
  
  148   Fri Jul 28 20:39:40 2006 Doug PreddyQuench RecoveryRestarting refrigeratorSolenoid quenched at about 6:00 tonight.
I restarted the compressor, then the cold
box and turbines. When cold box 
  
  149   Sat Jul 29 05:30:28 2006 Doug PreddyQuench Recoveryswitched to series modeTemps bottomed out at ~16K. Switching to series
mode.
  
  150   Sat Jul 29 09:38:06 2006 Doug PreddyQuench Recoverypower leads cooledopened power lead flow about 40 minutes ago.
~12K will let them stablize. 
LHE level >20%
  
  151   Tue Aug 8 07:27:49 2006 Doug PreddyQuench RecoverySolenoid Quench at about 6:00 this morningNo indication of problem. Turbines still running,
but no flow to solenoid. 
Started flow. Solenoid ~20K.
  
  152   Wed Aug 9 06:44:58 2006 Willy AnderssonQuench Recovery// cold mode cooling continues.After restarting flow to the solenoid yesterday
in // cold return mode 
TIC121 just refused to go lower than about
  
  153   Wed Aug 9 06:59:43 2006 Willy AnderssonQuench Recoverymore // cold return stuffAbout 21:00 last night the solenoid temps
had not changed much, pretty well 
flat lined. I guess my reducing CV155 stalled
  
  154   Wed Aug 9 07:50:49 2006 Doug PreddyQuench RecoverySwitched to series mode.Cool down continues.   
  156   Thu Aug 10 16:33:11 2006 Willy AnderssonQuench RecoveryFlow to solenoid tripped on powerlead temperature.Power lead temps were drifting up, tried to
tweak TIC121 and HIC141 to 
unstall powerlead flow. Got quench. Restarted
  
  157   Thu Aug 10 20:26:09 2006 Willy AnderssonQuench Recoverysolenoid energizedPowerleads seem stable.   
  158   Tue Aug 15 08:45:56 2006 Doug PreddyQuench Recoveryrestarted the compressorSolenoid tripped off Sunday. Restarted compressor
and cool down of cold box.
  
  159   Tue Aug 15 15:39:27 2006 Willy AnderssonQuench Recoveryswitched to parallel cold returnReturn flow temps from solenoid about 40K,
TIC121 at about 40K so switching 
to //cold return.
  
  160   Thu Aug 17 08:04:44 2006 Doug PreddyQuench RecoverySolenoid tripped at about 3:00 this morningrestarting system.
Compressor would not start. Idid not see
anything that would not let it 
  