M9sol Logbooks Solenoid Daily log
  Solenoid logbook, Page 6 of 15  ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Operational Modedown Subject
  104   Tue Jun 14 23:01:22 2005 Doug PreddyQuench Recoveryswitched to parallel cold return
  105   Mon Jul 18 11:18:40 2005 Doug PreddyQuench RecoverySolenoid Quenched over the weekend
The solenoid was found to be warm on Monday morning. M9Q3 had a bad water 
leak over the weekend. The water header serving Q3 was turned off and the 
leak confirmed. Q3 was isolated and the header was turned back on. My 
supposition is that while the main header was turned off, the diff. pump 
under the solenoid tripped. When I looked at it this morning the 
compressor was off and the vesssel vacuum was very bad. The PLC connection 
to EPICs is down, so I can not restart the vacuum system yet. Mike Leross 
is looking at the problem. 
There was no trip signal to the main control room. It looks as though the 
control room signal was bypassed downstairs. 
The power supply fault light was on on the QRL panel, but I okayed Bob 
Hilton locking out the power supply in order that Q3's water leak can be 
repired. Shutting of the main breaker may have turned on this light. The 
other possibility is that the power supply was not ramped down and shut 
off properly.
  106   Mon Jul 18 15:51:17 2005 Doug PreddyQuench RecoveryCompressor restarted, flow to solenoid
Recovered the vacuum in the solenoid, then started the compressor.
Started flow to solenoid in parallel warm return.
  107   Tue Jul 19 16:13:32 2005 Willy AnderssonQuench Recoveryswitch to series mode
CR_6KS_M down to 11 K.
Switched to series mode.
Started small flow to power leads to get them cold.
HIC142=0.6        Later open HIC142 wide open.
Raised discharge press to 11.4 barA.
Letting LHe level build.
  108   Tue Jul 19 18:09:56 2005 Willy AnderssonQuench RecoveryQuench II
Machine trip just as I was exiting the TRIUMF gate. QRL said cold box fault 
as did red lite on compressor. At cold box panel all turbine red lites were 
on and compressed air failure lite was on. But there was no problems with 
compressed air. On fist trip logger LED # 8 and 16 were lit. Restarted 
compressor then start flow to cold box, start turbines, start // warm 
return until temps returning back from solenoid were <= TIC121 then 
switched to //cold return mode. Opened cv155 to 0.88
Solenoid temps at 24K and starting to trend down.
  110   Mon Oct 31 07:48:57 2005 Willy AnderssonQuench Recoverywhat a fine entry
Keep IT safe boys
  112   Thu Nov 3 06:19:50 2005 Doug PreddyQuench Recoveryrestart system
Last night at about 7:00 there was a large power bump that shut the 
compressor and water pump off. I came in this morning and am restarting the 
system.
  113   Thu Nov 3 09:27:16 2005 Doug PreddyQuench Recoverystarted flow to solenoid
started flow to solenoid in parallel cold return.
  115   Mon Dec 12 09:24:29 2005 Doug PreddyQuench RecoverySolenoid Quench on power lead temp
The solenoid tripped on power lead temps at about 9:15. I am recovering it 
from it's all around mode into parallel cold return.
  124   Tue Jun 13 10:54:27 2006 Doug PreddyQuench RecoveryCompressor tripped off
No indicator lights etc as to why the compressor tripped. The only  light 
was a cold box fault. I had to shut off the main breaker before the 
compressor would come back on.
Started cooling in parallel  cold return.
  125   Tue Jun 13 15:52:46 2006 Willy AnderssonQuench RecoveryDoug has reduced and now closed CV155.
Now in full // cold return mode.
Had just talked with Curtis, He said thta he has already informed the 
experimentors that the solenoid will not be ready until tommorow, so he 
suggests leaving the system in reduced // cold mode overnight.
  126   Tue Jun 13 16:04:33 2006 Willy AnderssonQuench RecoveryTIC 121 set to auto mode
  127   Wed Jun 14 10:35:30 2006 Willy AnderssonQuench RecoverySwitched to series cooling.
Had system in //return cooling overnight with small flow to keep power 
leads cool. Switched to series mode about 30 minutes ago. Building LHe 
level.
  128   Wed Jun 14 16:27:01 2006 Willy AnderssonQuench RecoveryEnergized solenoid
Powerleads appear stable.
  132   Mon Jul 3 23:01:34 2006 Doug PreddyQuench Recoverypower lead warming/ripples caused quench
power lead warming/ripples caused quench at 18:45 today. Compressor stayed 
on, but flow to solenoid stopped.
I started flow to solenoid at 22:40.
  135   Thu Jul 20 00:25:16 2006 Doug PreddyQuench RecoverySolenoid quenched @ 11:15
Solenoid Quenched on C1 temp. It went above 5K. Shut off compressor. 
Restarting system @ 12:15
  136   Thu Jul 20 00:52:13 2006 Doug PreddyQuench RecoveryT1 frozen
T1 will not spin up. Warming up cold box.
  137   Thu Jul 20 02:59:06 2006 Doug PreddyQuench RecoveryT1 still not starting
I will leave the cold box to warm overnight and try it again in the morning.
  138   Thu Jul 20 08:18:31 2006 Doug PreddyQuench RecoveryT1 started
Started flow to turbines. Both started. T1 seems a bit slow. HIC110 at 0.85 
SI110 = 4100.
Cool down started.
  139   Thu Jul 20 11:01:09 2006 Willy AnderssonQuench RecoveryOpened up warm return valves CV151 and CV153
Mu2 pressure was just about at trip point due to trapped volume of helium 
warming. So opened up warm returns to bleed off pressure and prevent it 
from rising.
ELOG V2.9.2-2455