ID |
Date |
Author |
Operational Mode |
Subject |
|
46
|
Sun Aug 29 14:39:19 2004 |
Doug Preddy | Normal Running | Power lead ripple |
The LHe in and PL-neg temps have been building up a ripple over the last
few days. Curtis cycled HIC142 Friday evening at about 5:00. I just had
the Main control room operator (Peter) cycle them again. The ripples died
right out.
Originally the ripple was 10.8-11.4K on the LHe-in and 8.9-9.2K on the PL-
Neg. They are now steady at 10.7K and 8.9K. |
|
45
|
Wed Aug 25 12:52:53 2004 |
Doug Preddy | Normal Running | power lead ripple |
Lhe ripple has started. 10.9-11.4K PL-Pos also has a smaller ripple. Both
flows down to 230mm. Cycled HIC 142 and the ripple disappeared.
Put TIC121 into auto mode. |
|
44
|
Wed Aug 25 07:47:05 2004 |
Doug Preddy | Normal Running | Power lead flow |
The power lead flows had dropped to 210 mm this morning. I increased HIC142
from 0.8 to 0.83. The flows are back to <250 mm and the temps are back to
LHe in-10.8, PL-Pos-11.1, PL-Neg-8.9 |
|
43
|
Tue Aug 24 12:09:50 2004 |
Doug Preddy | Normal Running | The past few days |
The solenoid has been re-started as of August 19. It was cooled down and
energized over the weekend. Sunday night at 9:30 it tripped due to
negative power lead going above it's set point. The system stopped flow to
the solenoid, but kept the compressor and cold box running. While starting
flow to the solenoid, we got a high pressure trip. I came in and restarted
the compressor, after Curtis located and reset the over pressure
interlock. The solenoid is cold and energized as of 3:30 pm yesterday. It
is still stable as of now. |
|
42
|
Thu Aug 19 10:28:32 2004 |
Doug Preddy | Start Up | after M9bv5 FIX |
Over the last couple of days we replaced the gate on the M9BV5 valve. The
old one had worn the teflon sliders on the sides. Metal shavings on bottom
of body. Found a replacement with metal rollers, rather than slides.
Pumped out downstream of gate valve. It's down to 5E-7 (moved the cable on
the ion gauge so it now reads.)
Started cooling down the solenoid. Charging through the adsorber. LN2 fill
piping broke. Repaired by resoldering.
Ion gauge on solenoid seems to have burnt out last night. |
|
41
|
Sat Aug 7 23:40:47 2004 |
Willy Andersson | Quench Recovery | Energizing solenoid |
23:39 Powerleads cold, LHe level over 40% and rising. Energizing solenoid
to 500 Amps, ramp rate 60. Checking compressor building then going home. |
|
40
|
Sat Aug 7 22:37:04 2004 |
Willy Andersson | Quench Recovery | Compressor tripped off. |
Got a call at about 10:00 this morning, the whole system had tripped off.
No power bumps or other disturbances. When I arrived the only fault
indications were "ColdBox Trip" light on the compressor panel and on the
QRL panel the red "ColdBox" LED was ON. On the SULZER panel the
yellow "Cryostat Quench" light was ON. On the First Trip logger #1 and #15
LED's were ON. But no indication about what the actual fault was. Cooling
water OK, compressed air OK, compressor ventilation OK. Outside ambient
temperature was cooler than we had last week. BIG1 was off but when I
turned it back on the vacuum looked good but was slowly rising as the
solenoid warmed. I put the jumper on the vacuum controller. Prepared system
for re-start.
Started compressor. Started flow thru coldbox. Raised discharge pressure.
Started turbine flow. Didn't get any freezing but it seemed that T1 speed
wandered slowly +/-0.1k rev/sec when it got up to about 3.6k revs/sec, but
this only lasted for a second or two. Not sure if I was just seeing things.
Got turbines up to speed and started // warm return flow. Solenoid had been
running at 500 Amps and when it quenched and sat warming it had warmed to
about 40 K. Switched it to //cold return too soon and solenoid started to
warm slightly. Back to // warm return mode. Had to throttle flow thru
solenoid with warm return valves to get effective cooling. If had return
valves wide open TI121 would warm up too much. Discovered that if I
throttle the flow out of the solenoid slightly then TI121 would fall and
solenoid would start to cool. Less flow gave more cooling. Don't quite
understand that one. Switched to // cold return mode when solenoid temps
falling below 20K.
About 15:00 stable // cold return cooling. Going home for a while.
19:30 solenoid temps bottomed out at about 11K. Switch to series mode.
Something strange about the first trip detect. I reset it once and when I
checked it an hour or two later it showed a trip on #1 and #15 LED's even
though nothing had happened. Something must be causing false indications.
20:15 series cooling, solenoid temps at about 6K, LHe level rising slowly
at about 10%. Removed jumper on vacuum controller. |
|
39
|
Thu Jul 29 13:25:29 2004 |
Doug Preddy | Quench Recovery | start flow to power leads |
|
|
38
|
Thu Jul 29 09:01:11 2004 |
Doug Preddy | Quench Recovery | switched to parallel cold |
Changed to series mode. |
|
37
|
Wed Jul 28 23:07:01 2004 |
Doug Preddy | Quench Recovery | solenoid cooling |
cooling rates for the solenoid are good. In parallel cold return. |
|
36
|
Wed Jul 28 22:01:31 2004 |
Doug Preddy | Quench Recovery | Starting flow to solenoid |
c1 28, c12 29, c6 11.6, c7 12.5 TI121 22.5 |
|
35
|
Wed Jul 28 21:26:19 2004 |
Doug Preddy | Quench Recovery | Double Power bump |
Two power bumps tonight. Everything tripped of. Restarted cooling water
pump, diff. pump under solenoid etc. Computer stayed on! Starting
compressor. |
|
34
|
Wed Jul 28 07:00:18 2004 |
Doug Preddy | Quench Recovery | switch to series mode |
Switching to series mode. Jumper on vacuum gauge removed. |
|
33
|
Wed Jul 28 00:04:30 2004 |
Doug Preddy | Quench Recovery | started flow to solenoid |
Solenoid temps were: C1 & C12 about 30K. C6 &C7 about 11K. Started flow to
solenoid in parallel cold return. Jumpered out the vacuum gauge for the
solenoid vacuum. |
|
32
|
Tue Jul 27 23:33:27 2004 |
Doug Preddy | Quench Recovery | Solenoid quench 9:30 |
I was phoned at about 9:30 tonight with a solenoid alarm. After looking at
the display I found the system to be tripped off. When I came in I found
the compressor off and the solenoid quenched. There was no real indication
of the problem other than a cold box fault. I restarted the compressor and
started flow to the cold box.
Just a reminder: This elog is now at: https://elog.triumf.ca/M9sol |
|
31
|
Tue Jun 29 14:59:46 2004 |
Willy Andersson | Normal Running | Removed jumper on vacuum controller. |
Tuesday 14:55
Removed jumper on back of PIC 901. This jumper should be off during
normal operation so the solenoid/refrigerator is protected from bad vacuum. |
|
30
|
Fri Jun 25 14:20:58 2004 |
Willy Andersson | Quench Recovery | Switch to series mode |
At about 14:00 solenoid temps dipping below 8 K. Trace of LHe level (dense
gas) starting to show. Switching to series cooling mode. |
|
29
|
Fri Jun 25 12:36:04 2004 |
Willy Andersson | Quench Recovery | Compressor unloaded etc. |
At about 09:30 this morning I noticed the sound coming from the compressor
building seemed louder than usual. After entering the building I noted that
the compressor was unloaded to about 50% and the compressor suction was
running at about 15 psig. Down at the SULZER panel the solenoid vacuum
system was tripped off, the flow was still in series mode but no LHe level,
solenoid temps at over 40 K. Contacted Doug. Cannot figure out why the
compressor was unloaded to 50 %. Solenoid had not tripped on bad vacuum
because jumper was still on PIC901. Doug mentioned there was a power bump
yesterday at about 15:00. May be when the vacuum system tripped but does
not explain the compressor unloading.
Doug restarted vacuum system. I stopped flow to solenoid. Stabilized
pressures. We checked the compressor to try to see what would cause the
Unloaded state. Could not see any oil leaks.
Back at Sulzer panel loaded compressor to 100 %. Stabilize pressures. STart
cooling flow to solenoid, // warm return. Adjusting turbine speeds and
shield heat as required. Switched to // cold return flow after solenoid
temps down to TIC 121 temp of about 20 K. |
|
28
|
Fri May 21 09:27:39 2004 |
Doug Preddy | Maintenance | Idle mode |
Power supply was ramped down yesterday as there are no users.
The Sundance server was rebooted yesterday. This morning the displays were
all white screened, so I restarted the session. The computer was running
very slow and I could not get the strip tool to run at all. I rebooted the
local PC and everything seems to be okay now.
While rebooting the computer had an error message that the hard drive may
have some bad sectors. Did a scan disk and it seems okay, but the hard
drive might be dying in the local machine. |
|
27
|
Thu May 6 09:32:13 2004 |
Willy Andersson | Quench Recovery | Additional notes from last night power lead problems. |
When performing last nights refrigerator adjustments I also increased the
compressor discharge pressure to 11.25 barA. Also the backup air compressor
was tripped off again and I reset it. Finally I opened the city water flow
to the compressor water package chiller. PI110-1 reads 9.25 barA and PI120-1
reads just over 4 barA. Both power lead flowmeters pegged to top of scale.
Reset the "first trip" device that Don Dale had loaned us.
This morning the power leads had crept up slightly but still well below
trip settings. Oscillations have not appeared yet. LHe vessel heater at
about 14 to 15 %. Shield heat at about 16 %. Saved screen shots of
m9_solenoid.dl and striptool windows to files may6_04_0900.BMP and
may6_04_0905.BMP. TE106 is 81.6 Kelvin. Solenoid Current is stable at 404
Amps. (DVM meter reads 20.2) Both power lead flowmeters still pegged to top
of scale.
Closed HIC142 for 1 second then opened it wide open again to see effect on
power lead flows. Other than the initial blip they just fall back to their
previous value, no improvement. See file may6_04_0915.BMP. Adjusting
turbine speeds slightly. Going to take a check in the compressor building
then going on to other work. |