  197   Wed May 30 08:38:38 2007 Doug PreddyQuench RecoverySolenoid quenched this morningSolenoid quenched this morning on power lead
temp (I believe).
I restarted it at ~7:00, but the capacity
  
  198   Wed May 30 11:27:32 2007 Doug PreddyQuench RecoveryProblems recoveringVarious start up problems :
MV51 stuck open. Finally got it closed by
hitting the valve with a hammer.
  
  199   Thu May 31 07:11:05 2007 Doug PreddyQuench Recoveryswitched to parallel cold returnswitched to parallel cold return earlier this
morning. Vacuum is 5 x 10-5.
  
  200   Thu May 31 11:51:49 2007 Doug PreddyQuench RecoverySwitched to series mode    
  201   Tue Jun 12 12:48:25 2007 Doug PreddyMaintenanceadded one bottle UHP helium to system    
  202   Thu Jun 14 00:10:10 2007 Doug PreddyQuench Recoveryrecovering from earlier quenchSolenoid quenched on power lead temperature
last night at about 6:00. I 
restarted flow to the solenoid in parallel
  
  203   Sat Jun 16 15:05:03 2007 Doug PreddyNormal RunningSolenoid power lead temp problemPower lead temps rippling and increasing.
I asked an operator to cycle 
HIC142. This seems to have fixed the problem
  
  204   Tue Jun 19 21:15:41 2007 Doug PreddyQuench RecoveryToday's quenchpower lead temps caused a quench at 8:30 this
morning. Recovery of system 
and flow to solenoid was started by 11:00.
  
  205   Sun Jul 1 16:09:37 2007 Doug PreddyNormal RunningM9B:DP2 tripped off Diffusion pump tripped off and vacuum (and
power lead temps) going up. I 
had an experimentor cycle HIC 142 at 4:15
  
  206   Wed Jul 4 11:13:12 2007 Doug PreddyQuench RecoverytestThis is a test to make sure the e-mail works.   
  207   Thu Jul 5 03:04:50 2007 Doug PreddyNormal RunningPower lead problemsThe power leads temps are starting to cycle
again. Earlier today M9 
experimentor cycled HIC142 to stablize the
  
  209   Sat Jul 28 15:45:17 2007 Doug PreddyQuench Recoveryquench recoveryThe solenoid tripped off this morning due
to pwer lead over temp. The 
compressor was also off. I restarted this
  
  210   Sat Jul 28 22:30:13 2007 Doug PreddyQuench Recoveryquench againrecovered system and energized solenoid at
about 6:00 this evening.
At 9:30 power lead temps quenched solenoid
  
  211   Sun Jul 29 04:58:27 2007 Doug PreddyQuench RecoveryEnergizing solenoidLHe level~50%. Still have a slight ripple
in the power leads, but they are 
cold enough to power the solenoid. LHe_in
  
  213   Mon Aug 6 08:41:31 2007 Doug PreddyQuench RecoveryCold box trip at 6:00compressor off due to cold box trip at 6:00
this morning. Restarted system 
and started flow to solenoid in parallel
  
  214   Tue Aug 14 10:15:22 2007 Doug PreddyMaintenanceSolenoid ramped downSolenoid ramped down and locked out for M9A
slits work.
  
  215   Tue Aug 14 12:55:12 2007 Doug PreddyNormal RunningStrip tool savesThere are two strip tools saved:
coils
powerlead
  
  216   Wed Sep 12 12:01:02 2007 Doug PreddyMaintenanceregenerated adsorberregenerated adsorber
replaced MV902 "ON" switch (used nitrogen
precooling on switch)
  
  217   Fri Sep 14 12:44:52 2007 Doug PreddyStart Upstarted compressorrunning purifier over weekend   
  219   Wed Sep 19 20:53:18 2007 Doug PreddyMaintenanceMore diff pump newsCold box pumped out to ~ 190 mTorr overnight.Leak
checked the pump again. 
Still leaks at dip stick.Tried resetting
  