ID |
Date |
Author |
Type |
Category |
Subject |
2
|
Fri Nov 29 16:00:09 2013 |
Naomi | | General | MIDASUK sort | 1) some info is written in tuda/Documents/READMEs/readme.MIDASsort
MIDAS Main Menu -> Sorting -> MIDASsort
enter sort.f file in Sortfile window and compile with Compile Sortfile
- example file sort3.f with the variables.dat file that contains gain, offset, calibration and other variables, is attached below.
- the base code which just unpacks data without sorting it, sort.f is also attached
- make sure you have the correct path for the variables.dat file in sort3.f
- Note that this variables.dat file was downloaded on a Mac OSX and which adds extra invisible characters at the end of each line and therefore won't be read in properly in MIDASsort.
for online sorting go to Input Media -> Online
for offline sorting go to Input Media -> Disc, the Disc Info. Browse file, Add it and Save and Quit
hit Start button to run sort file. the output is printed in the terminal running MIDAS-session
in Spectrum Directory Browser or Spectrum Viewer go to Resource -> SortSas the Redisplay. here you'll see all spectra created in sort.f
you can add a spectrum title files like the example given below in the Spectrum Directory Browser via Actions -> Apply title and then Options -> Details
- you can add titles for the Resource -> hist spectra with the another title file
if the spectra don't refresh properly Select all and Actions -> Delete in Spectrum Directory Browser and then Start the sorting program
2) you can view online spectra in Spectrum Directory Browser -> Resource -> hist
remember to Select all and Actions -> zero and deselect if you want to view only the current run, otherwise you are seeing the spectra of incremented runs
3) to get gain, offset and calibration coefficients go to tuda/Documents/READMEs/readme.calibration
you need to have pulsar runs with amplitude varied from 90,000 to 10,000 in step size of 10,000 and the peaks should span the entire spectrum if possible and all contain ~1000 counts
you need 3-alpha calibration source runs
- gain and offsets are calculated for ADCs and offsets only for TDCs since clock is the same and there are offsets due to cable lengths, hence delay times
- Tom did this for us since we couldn't figure out the first step in the readme file using the peakfind program. The correct syntax for future knowledge is:
peakfind -spectrum <spectrum file name> -limit <low limit> <high limit> -fwhm <fwhm> -accept <accept>
4) to view scalars during run go to VME Module Control -> CEN V560 scalar and wait 10 s for refresh rate
5) meaning of c and w variables in sort3.f
c(0) and c(1) are calibration constants
c(8) and c(9) are used in equation pi (particle identification) which uses the total energy of S2 delE and E
c(8)=b is based on the semi-empirical range formula of charged particles in the detector r=(a*E)^b. You can find the values in the Knoll book of F. Goulding paper.
c(9) stretches the spectrum and can be a value between 0.5 and 5
w(0) and w(1) are windows for the (front strip - back strip) S2 delE values which should be a Gaussian peak centered around 2048, an arbitrary value so that the center is not around 0.
w(2) and w(3) are the same but for S2 E
w(17) and w(18) are windows used to select a particle type from the equation pi
w(19) and w(20) ignore. was used for a second delE and E detector in a previous experiment
6) summary of spectra created and used in sort3.f:
0-351 1D ADC histograms
3100-3115 1D scalar histograms
3000 1D channels w/ hits
3003 2D ADC ch vs ADC histo ch
3006 1D multiplicity + (3000 + number of good delE hits) + (3100 + number of good E hits)
3050 2D S2 delE front vs back
3060 1D S2 delE (front - back)
3051 2D S2 delE good front vs back
3061 1D S2 delE good (front - back)
3052 2D S2 E front vs back
3062 1D S2 E (front - back)
3053 2D S2 E good front vs back
3063 1D S2 E good (front - back)
4000 2D S2 energy vs annulus strip + (48 + energy vs annulus strip)
4010 2D S2 delE vs E
4011 1D pi
4012 2D pi vs tot energy
4013 1D total energy of selected particle using gates w(17) and w(18)
7) unpacking raw data in sort.f
ADC channels are put into channels 0-999
ADCs have 32 channels each and the first module is in the right slot of the VME crate.
TDC channels are put into channels 1000-1999 and ADC channel 1 corresponds to TDC channel 1001
TDC have 128 channels but only 112 channels are used. The first 16 are empty. So channels 16-127 from TDC#1 are put into channel 1000-1111 and from TDC#2 into channel 1112-1223, etc |
Attachment 1: sort3.f
|
*trigger
128
*oned
0..351 s 4096
1000..1335 s 512
3000 s 1024
3001 s 1024
3002 s 1024
3006 s 4096
3060..3067 s 4096
3100..3115 s 16384
4011 s 1024
4013 s 1024
4015 s 1024
4017 s 1024
*twod
2000..2335 s 512 512
3003 s 512 512
3004 s 512 512
3005 s 512 512
3050..3057 s 512 512
4000..4007 s 512 512
4010 s 512 512
4012 s 512 512
4014 s 512 512
4016 s 512 512
*vars
*sort
C----67---------------------------------------------------------------72------80
C http://npg.dl.ac.uk/MIDAS/manual/MIDASsortHOWTO/info.pdf
SUBROUTINE init
IMPLICIT none
SAVE
C
C External functions
C
EXTERNAL de_1h_al, de_1h_cd2, dtime, elab2ex, gate2d, path_factor
EXTERNAL s2order, s2_1_theta, s2_3_theta
C
INTEGER and, gate2d, int, rshift, s2order
C
REAL de_1h_al, de_1h_cd2, dtime, elab2ex, float, path_factor, rand
REAL s2_1_theta, s2_3_theta
C
C Parameter variables
C
INTEGER maxadcs
PARAMETER (maxadcs = 2200)
INTEGER adcs_max
PARAMETER (adcs_max = 11*32)
INTEGER tdcs_max
PARAMETER (tdcs_max = 3*112) !not 3*127?
INTEGER maxscalers
PARAMETER (maxscalers = 16)
INTEGER maxepics
PARAMETER (maxepics = 64)
INTEGER event_prescaler
PARAMETER (event_prescaler = 1000000)
INTEGER scaler_prescaler
PARAMETER (scaler_prescaler = 1000000)
INTEGER epics_prescaler
PARAMETER (epics_prescaler = 1000000)
C
LOGICAL csm
PARAMETER (csm = .true.)
C
C Local variables !**********************************************
C
INTEGER channel, counter_old(0:maxscalers-1), data(0:maxadcs-1)
INTEGER epics_counter, events, events_old, gate1(18), good_s2_1
INTEGER good_s2_1_back(0:63), good_s2_1_front(0:63), good_s2_2
INTEGER good_s2_2_back(0:63), good_s2_2_front(0:63), i
INTEGER*2 i2(2)
INTEGER i4, ierr, iflag, ireturn, ix, iy, j, k, l, monitor(0:9)
INTEGER monitor_old(0:9), m_adc, m_tdc, scaler(0:maxscalers-1)
INTEGER scaler_old(0:maxscalers-1), sc_counter, sector
INTEGER sum(0:maxscalers-1), type, w(0:31)
C
LOGICAL good_s2_1_event, good_s2_2_event, hit(0:maxadcs-1)
C
REAL c(0:31), de1, de2, dt, e(0:adcs_max-1), e1, e2, ediff
REAL epics(0:maxepics-1), event_rate, e_lab, e_x
REAL gain(0:maxadcs-1), lt, offset(0:maxadcs-1), pi, r4
REAL rate(0:maxscalers-1), temp, time(2)
C
C Namelists
C
NAMELIST /variables/ offset, gain, c, w
C
C Common variables
C
INTEGER*2 adc_data(0:maxadcs-1)
C
COMMON /fdata/ adc_data
C
C Common variables
C
INTEGER*2 adcs(0:maxadcs-1)
C
COMMON /fid/ adcs
C
C Common variables
C
INTEGER noadcs
C
COMMON /fmult/ noadcs
C
EQUIVALENCE ( i4, i2( 1 ) )
C MIDAS polygon
C {{396 96} {404 109} {421 124} {448 144} {475 144} {454 129} {432 113} {416 96}}
C
!**********************************************
DATA gate1 /396, 96,404,109,421,124,448,144,475,144,454,129,
+ 432,113,416, 96, -1, -1/
C----67---------------------------------------------------------------72------80
WRITE ( 6, * ) ' *** S1284 - sort3 - November 2013'
WRITE ( 6, * ) ' *** Entry init commences'
C Initialise arrays for unpacked event data.
DO i = 0, maxadcs - 1
data( i ) = 0
hit( i ) = .FALSE.
ENDDO
C Initialise gains/offsets
DO i = 0, maxadcs - 1
gain( i ) = 1.0
offset( i ) = 0.0
ENDDO
C Initialise constants/1D windows
DO i = 0, 31
c( i ) = 1.0
w( i ) = 0
ENDDO
C Initialise scalers
DO i = 0, maxscalers - 1
scaler( i ) = 0
scaler_old( i ) = 0
counter_old( i ) = 0
rate( i ) = 0.0
ENDDO
C Initialise counters
sc_counter = 0
epics_counter = 0
events = 0
events_old = 0
channel = 0
DO i = 0, 9
monitor( i ) = 0
monitor_old( i ) = 0
ENDDO
OPEN( 1, FILE = '/home/tuda/S1284/calibration/variables.dat',
+ IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** OPEN I/O error:', ierr
RETURN
ENDIF
READ( 1, NML = variables, IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** READ I/O error:', ierr
ENDIF
CLOSE( 1, IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** CLOSE I/O error:', ierr
RETURN
ENDIF
C Display program variables
DO i = 0, adcs_max-1, 8
WRITE( 6, 9001 ) i, i+7, ( gain( j ), j = i, i+7 )
ENDDO
DO i = 0, adcs_max-1, 8
WRITE( 6, 9002 ) i, i+7, ( offset( j ), j = i, i+7 )
ENDDO
DO i = 1000, 1000+tdcs_max-1, 8
WRITE( 6, 9002 ) i, i+7, ( offset( j ), j = i, i+7 )
ENDDO
DO i = 0, 31, 8
WRITE( 6, 9003 ) i, i+7, ( c( j ), j = i, i+7 )
ENDDO
DO i = 0, 31, 8
WRITE( 6, 9004 ) i, i+7, ( w( j ), j = i, i+7 )
ENDDO
WRITE ( 6, * ) ' *** Entry init ends'
RETURN
C----67---------------------------------------------------------------72------80
ENTRY sortin
events = events + 1
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
rate = FLOAT( events - events_old ) / dtime(time)
WRITE( 6, * ) ' *** event:', events, ' (', rate,' events/s)'
events_old = events
ENDIF
C Convert Eurogam type 0 ID to (a more) logical channel number.
C ADC data channels 0-999
C TDC data channels 1000-1999
C Scaler data channels 2000-2099
C EPICS data channels 2100-2199
call egid2logical( noadcs, adcs, adc_data, type, csm )
C----67---------------------------------------------------------------72------80
C Event data.
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
WRITE( 6, * ) ' *** Packed event:', events, ' noadcs:', noadcs
DO i = 0, noadcs - 1
WRITE( 6, 9050 ) adcs( i ), adc_data( i )
ENDDO
ENDIF
C Unpack event data from packed data arrays.
c If you want to write events in ascii format do it here event number = 'events'
DO i = 0, noadcs - 1
IF ( adcs( i ).GE.0 .AND. adcs( i ).LT.maxadcs ) THEN
data( adcs( i ) ) = adc_data( i )
hit( adcs( i ) ) = .TRUE.
ENDIF
ENDDO
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
WRITE( 6, * ) ' *** Unpacked event:', events
DO i = 0, adcs_max-1, 16
c WRITE(6,9060) i, i+15, (data(j),hit(j),j=i,i+15)
ENDDO
DO i = 1000, 1000+tdcs_max-1, 16
c WRITE(6,9060) i, i+15, (data(j),hit(j),j=i,i+15)
ENDDO
ENDIF
C----67---------------------------------------------------------------72------80
C Scaler data.
IF ( AND( X'00000002', type ).EQ.2 ) THEN
C IF ( MOD( sc_counter, scaler_prescaler ).EQ.0 ) THEN
C WRITE( 6, 9010 ) sc_counter
C DO i = 0, maxscalers-1, 4
C WRITE( 6, 9020 ) i, i+3, ( scaler(j),
C + 1.0E-03 * rate(j), j = i, i+3 )
C ENDDO
C ENDIF
j = 0
DO i = 2000, 2000 + ( 2 * maxscalers ) - 1, 2
i2( 1 ) = data( i + 1 )
i2( 2 ) = data( i )
scaler( j ) = i4
j = j + 1
ENDDO
C Scalers are reset at the start of each run.
C
C Note that scalers do not necessarily increase monotonically
C from event to event - this probably indicates that the most
C frequently changing (least significant) bits are not stable
C at readout.
IF ( scaler( 2 )+100.LT.counter_old( 2 ) ) THEN
DO i = 0, maxscalers - 1
sum( i ) = sum( i ) + counter_old( i )
counter_old( i ) = 0
ENDDO
ELSE
DO i = 0, maxscalers - 1
counter_old( i ) = scaler( i )
ENDDO
ENDIF
IF ( scaler( 2 ).LT.scaler_old( 2 ) ) THEN
... 857 more lines ...
|
Attachment 2: variables.dat
|
$variables
offset( 0) = 31.41
offset( 1) = 31.29
offset( 2) = 31.79
offset( 3) = 31.87
offset( 4) = 33.64
offset( 5) = 31.30
offset( 6) = 32.19
offset( 7) = 33.39
offset( 8) = 34.29
offset( 9) = 33.57
offset( 10) = 36.11
offset( 11) = 37.50
offset( 12) = 37.62
offset( 13) = 35.17
offset( 14) = 35.58
offset( 15) = 37.27
offset( 16) = -9999.99
offset( 17) = 32.02
offset( 18) = 37.84
offset( 19) = 36.62
offset( 20) = 36.39
offset( 21) = 36.95
offset( 22) = 37.84
offset( 23) = 35.13
offset( 24) = 35.62
offset( 25) = 34.73
offset( 26) = 35.63
offset( 27) = 38.12
offset( 28) = 36.32
offset( 29) = 35.51
offset( 30) = 32.97
offset( 31) = 35.77
offset( 32) = 31.75
offset( 33) = 33.50
offset( 34) = 33.28
offset( 35) = 33.97
offset( 36) = 32.90
offset( 37) = 32.63
offset( 38) = 32.89
offset( 39) = 33.37
offset( 40) = -17.41
offset( 41) = -13.32
offset( 42) = -13.73
offset( 43) = -12.24
offset( 44) = -14.26
offset( 45) = -12.23
offset( 46) = -12.82
offset( 47) = -12.28
offset( 48) = 24.16
offset( 49) = 28.12
offset( 50) = 45.24
offset( 51) = 26.33
offset( 52) = -9999.99
offset( 53) = -9999.99
offset( 54) = -9999.99
offset( 55) = -9999.99
offset( 56) = 40.21
offset( 57) = 39.20
offset( 58) = 33.12
offset( 59) = 35.13
offset( 60) = 36.40
offset( 61) = 35.18
offset( 62) = 35.74
offset( 63) = 36.09
offset( 64) = 27.40
offset( 65) = 27.24
offset( 66) = 27.52
offset( 67) = 27.10
offset( 68) = 27.57
offset( 69) = 27.70
offset( 70) = 29.03
offset( 71) = 26.87
offset( 72) = -36.36
offset( 73) = -31.53
offset( 74) = -30.36
offset( 75) = -29.43
offset( 76) = -30.47
offset( 77) = -28.96
offset( 78) = -32.84
offset( 79) = -31.52
offset( 80) = -23.06
offset( 81) = -18.09
offset( 82) = -15.50
offset( 83) = -19.60
offset( 84) = -18.12
offset( 85) = -18.66
offset( 86) = -16.42
offset( 87) = -22.14
offset( 88) = -22.39
offset( 89) = -18.49
offset( 90) = -19.65
offset( 91) = -17.35
offset( 92) = -20.03
offset( 93) = -16.58
offset( 94) = -18.52
offset( 95) = -22.13
offset( 96) = 43.37
offset( 97) = 44.19
offset( 98) = 43.32
offset( 99) = 41.98
offset( 100) = 43.88
offset( 101) = 43.42
offset( 102) = 43.98
offset( 103) = 41.18
offset( 104) = 51.60
offset( 105) = 49.56
offset( 106) = 48.34
offset( 107) = 49.15
offset( 108) = 48.39
offset( 109) = 49.26
offset( 110) = 48.76
offset( 111) = 49.65
offset( 112) = 28.31
offset( 113) = 25.35
offset( 114) = 21.72
offset( 115) = 23.50
offset( 116) = 24.52
offset( 117) = 28.99
offset( 118) = 27.40
offset( 119) = 23.97
offset( 120) = 29.23
offset( 121) = 30.69
offset( 122) = 29.95
offset( 123) = 27.70
offset( 124) = 28.73
offset( 125) = 30.00
offset( 126) = 29.31
offset( 127) = 30.25
offset( 128) = 20.90
offset( 129) = 22.26
offset( 130) = 22.64
offset( 131) = 26.74
offset( 132) = 24.38
offset( 133) = 22.22
offset( 134) = 22.90
offset( 135) = 23.62
offset( 136) = 27.99
offset( 137) = 26.52
offset( 138) = 27.80
offset( 139) = 27.41
offset( 140) = 25.65
offset( 141) = 26.23
offset( 142) = 26.12
offset( 143) = 24.43
offset( 144) = 27.80
offset( 145) = 27.06
offset( 146) = 29.27
offset( 147) = 30.10
offset( 148) = 28.28
offset( 149) = 27.17
offset( 150) = 28.03
offset( 151) = 25.26
offset( 152) = 27.64
offset( 153) = 23.81
offset( 154) = 24.29
offset( 155) = 26.64
offset( 156) = 25.77
offset( 157) = 25.07
offset( 158) = 23.78
offset( 159) = 25.81
offset( 160) = 22.41
offset( 161) = 25.83
offset( 162) = 26.11
offset( 163) = 23.48
offset( 164) = 26.00
offset( 165) = 23.42
offset( 166) = 20.81
offset( 167) = 23.35
offset( 168) = 25.29
offset( 169) = 21.69
offset( 170) = 22.04
offset( 171) = 21.08
offset( 172) = 23.79
offset( 173) = 19.86
offset( 174) = 19.94
offset( 175) = 19.68
offset( 176) = 28.38
offset( 177) = 26.20
offset( 178) = 27.22
offset( 179) = 25.10
offset( 180) = 31.31
offset( 181) = 29.20
offset( 182) = 27.74
offset( 183) = 24.80
offset( 184) = 26.69
offset( 185) = 27.00
offset( 186) = 26.83
offset( 187) = 24.19
offset( 188) = 22.71
offset( 189) = 24.02
offset( 190) = 23.84
offset( 191) = 21.18
offset( 192) = 19.09
offset( 193) = 20.71
offset( 194) = 18.45
offset( 195) = 19.36
offset( 196) = 19.31
offset( 197) = 19.02
offset( 198) = 19.95
offset( 199) = 18.29
offset( 200) = -23.34
offset( 201) = -24.26
offset( 202) = 0.00
offset( 203) = -23.53
offset( 204) = -26.73
offset( 205) = -23.81
offset( 206) = -24.30
offset( 207) = -27.00
offset( 208) = -19.63
offset( 209) = -21.13
offset( 210) = -22.79
offset( 211) = -9999.99
offset( 212) = -22.70
offset( 213) = -22.73
offset( 214) = -24.32
offset( 215) = -23.63
offset( 216) = -38.25
offset( 217) = -38.35
offset( 218) = -38.55
offset( 219) = -39.72
offset( 220) = -38.57
offset( 221) = -40.33
offset( 222) = -40.50
offset( 223) = -41.18
offset( 224) = 25.74
offset( 225) = 27.95
offset( 226) = 27.69
offset( 227) = 25.68
offset( 228) = 27.78
offset( 229) = 27.97
offset( 230) = 26.08
offset( 231) = 28.08
offset( 232) = -32.10
offset( 233) = -32.45
offset( 234) = -33.02
offset( 235) = -32.41
offset( 236) = -32.52
offset( 237) = -24.52
offset( 238) = -32.77
offset( 239) = -34.87
offset( 240) = -33.55
offset( 241) = -35.15
offset( 242) = -34.74
offset( 243) = -34.38
offset( 244) = -34.24
offset( 245) = -34.78
offset( 246) = -34.57
offset( 247) = -34.79
offset( 248) = -36.63
offset( 249) = -36.75
offset( 250) = -35.59
offset( 251) = -35.02
offset( 252) = -37.42
offset( 253) = -37.84
offset( 254) = -36.60
offset( 255) = -37.22
gain( 0) = 0.9408154
gain( 1) = 0.9432995
gain( 2) = 0.9275470
gain( 3) = 0.9044398
gain( 4) = 1.0000000
gain( 5) = 0.9106534
gain( 6) = 0.9723005
gain( 7) = 0.9143751
gain( 8) = 0.9632197
gain( 9) = 0.9683237
gain( 10) = 0.9703364
gain( 11) = 0.9284047
gain( 12) = 0.9579666
gain( 13) = 0.9669750
gain( 14) = 0.9431901
gain( 15) = 0.9444321
gain( 16) = -1.9999999
gain( 17) = -1.9999999
gain( 18) = 0.9527306
gain( 19) = 0.9462996
gain( 20) = 0.9657578
gain( 21) = 0.9265667
gain( 22) = 0.9205554
gain( 23) = 0.9162895
gain( 24) = 0.9413665
gain( 25) = 0.9282222
gain( 26) = 0.9303361
gain( 27) = 0.9378214
gain( 28) = 0.9456897
gain( 29) = 0.9602508
gain( 30) = 0.9427250
gain( 31) = 0.9513409
gain( 32) = 0.9119371
gain( 33) = 0.9569856
gain( 34) = 0.9309798
gain( 35) = 0.9473361
gain( 36) = 0.9212945
gain( 37) = 0.9826480
gain( 38) = 0.9588793
gain( 39) = 0.9500576
gain( 40) = 0.9413007
gain( 41) = 0.9313699
gain( 42) = 0.9417806
... 97 more lines ...
|
Attachment 3: S1284_sort_spectrum_titles.txt
|
s0 DE1 p+n strip 0 ADC
s47 DE1 p+n strip 47 ADC
s48 DE1 n+n strip 0 ADC
s63 DE1 n+n strip 15 ADC
s64 E1 p+n strip 0 ADC
s111 E1 p+n strip 47 ADC
s112 E1 n+n strip 0 ADC
s127 E1 n+n strip 15 ADC
s128 DE2 p+n strip 0 ADC
s175 DE2 p+n strip 47 ADC
s176 DE2 n+n strip 0 ADC
s191 DE2 n+n strip 15 ADC
s192 E2 p+n strip 0 ADC
s239 E2 p+n strip 47 ADC
s240 E2 n+n strip 0 ADC
s255 E2 n+n strip 15 ADC
s1000 DE1 p+n strip 0 TDC
s1047 DE1 p+n strip 47 TDC
s1048 DE1 n+n strip 0 TDC
s1063 DE1 n+n strip 15 TDC
s1064 E1 p+n strip 0 TDC
s1111 E1 p+n strip 47 TDC
s1112 E1 n+n strip 0 TDC
s1127 E1 n+n strip 15 TDC
s1128 DE2 p+n strip 0 TDC
s1175 DE2 p+n strip 47 TDC
s1176 DE2 n+n strip 0 TDC
s1191 DE2 n+n strip 15 TDC
s1192 E2 p+n strip 0 TDC
s1239 E2 p+n strip 47 TDC
s1240 E2 n+n strip 0 TDC
s1255 E2 n+n strip 15 TDC
s2000 DE1 p+n strip 0 TDC versus ADC
s2047 DE1 p+n strip 47 TDC versus ADC
s2048 DE1 n+n strip 0 TDC versus ADC
s2063 DE1 n+n strip 15 TDC versus ADC
s2064 E1 p+n strip 0 TDC versus ADC
s2111 E1 p+n strip 47 TDC versus ADC
s2112 E1 n+n strip 0 TDC versus ADC
s2127 E1 n+n strip 15 TDC versus ADC
s2128 DE2 p+n strip 0 TDC versus ADC
s2175 DE2 p+n strip 47 TDC versus ADC
s2176 DE2 n+n strip 0 TDC versus ADC
s2191 DE2 n+n strip 15 TDC versus ADC
s2192 E2 p+n strip 0 TDC versus ADC
s2239 E2 p+n strip 47 TDC versus ADC
s2240 E2 n+n strip 0 TDC versus ADC
s2255 E2 n+n strip 15 TDC versus ADC
s3000 ADC Hit Pattern
s3001 TDC Hit Pattern
s3002 ADC.TDC Hit Pattern
s3003 channel versus ADC
s3004 channel versus TDC
s3005 TDC channel versus ADC channel
s3006 Multiplicity
s3050 DE1 p+n energy versus n+n energy
s3051 DE1 p+n energy versus n+n energy: gated
s3052 E1 p+n energy versus n+n energy
s3053 E1 p+n energy versus n+n energy: gated
s3054 DE2 p+n energy versus n+n energy
s3055 DE2 p+n energy versus n+n energy: gated
s3056 E2 p+n energy versus n+n energy
s3057 E2 p+n energy versus n+n energy: gated
s3060 DE1 E(p+n) - E(n+n) + 2048
s3061 DE1 E(p+n) - E(n+n) + 2048: gated
s3062 E1 E(p+n) - E(n+n) + 2048
s3063 E1 E(p+n) - E(n+n) + 2048: gated
s3064 DE2 E(p+n) - E(n+n) + 2048
s3065 DE2 E(p+n) - E(n+n) + 2048: gated
s3066 E2 E(p+n) - E(n+n) + 2048
s3067 E2 E(p+n) - E(n+n) + 2048: gated
s3100 Scaler #0 - triggers - 1000*rate(Hz) updated every 60s
s3101 Scaler #1 - triggers accepted
s3102 Scaler #2 - 1kHz clock
s3103 Scaler #3 - pulser
s3104 Scaler #4
s3108 Scaler #8
s3109 Scaler #9
s3110 Scaler #10
s3111 Scaler #11
s3112 Scaler #12
s3113 Scaler #13
s3114 Scaler #14
s3115 Scaler #15
s4000 Energy vs ordered strip S2s
s4002 Energy vs ordered strip for 'good' events S2s
s4004 dE1+E1 (proton gate) lab energy versus S2-1 strip #
s4005 dE1+E1 (proton gate) excitation energy versus S2-1 strip #
s4006 dE2+E2 (proton gate) lab energy versus S2-3 strip #
s4007 dE2+E2 (proton gate) excitation energy versus S2-3 strip #
s4008 Energy vs ordered strip LEDAs
s4010 S2-2 E1 versus S2-1 dE1 (100keV/channel)
s4011 Particle ID
s4012 Particle ID versus dE1+E1 (100keV/channel)
s4013 dE1+E1 (proton gate) (100keV/channel)
s4014 S2-4 E2 versus S2-3 dE2 (100keV/channel)
s4015 Particle ID
s4016 Particle ID versus dE2+E2 (100keV/channel)
s4017 dE2+E2 (proton gate) (100keV/channel)
s4018 dE1+E1 (proton gate) lab energy versus angle
s4019 dE2+E2 (proton gate) lab energy versus angle
s4120 dphi
|
Attachment 4: S1284_VME_spectrum_titles.txt
|
s9418#1.adc0 dE1 p+n strip 0 ADC
s9418#2.adc15 dE1 p+n strip 47 ADC
s9418#2.adc16 dE1 n+n strip 0 ADC
s9418#2.adc31 dE1 n+n strip 15 ADC
s9418#3.adc0 E1 p+n strip 0 ADC
s9418#4.adc15 E1 p+n strip 47 ADC
s9418#4.adc16 E1 n+n strip 0 ADC
s9418#4.adc31 E1 n+n strip 15 ADC
s9418#5.adc0 dE2 p+n strip 0 ADC
s9418#6.adc15 dE2 p+n strip 47 ADC
s9418#6.adc16 dE2 n+n strip 0 ADC
s9418#6.adc31 dE2 n+n strip 15 ADC
s9418#7.adc0 E2 p+n strip 0 ADC
s9418#8.adc15 E2 p+n strip 47 ADC
s9418#8.adc16 E2 n+n strip 0 ADC
s9418#8.adc31 E2 n+n strip 15 ADC
s9418#9.adc0 LEDA-0 strip 0 ADC
s9418#9.adc15 LEDA-0 strip 15 ADC
s9418#9.adc16 LEDA-1 strip 0 ADC
s9418#9.adc31 LEDA-1 strip 15 ADC
s9418#10.adc0 LEDA-2 strip 0 ADC
s9418#10.adc15 LEDA-2 strip 15 ADC
s9418#10.adc16 LEDA-3 strip 0 ADC
s9418#10.adc31 LEDA-3 strip 15 ADC
s9418#11.adc0 PIN photodiode 1 ADC
s9418#11.adc1 PIN photodiode 2 ADC
s9418#11.adc2 PIN photodiode 3 ADC
s9418#11.adc3 PIN photodiode 4 ADC
v1190#1.tdc16 dE1 p+n strip 0 TDC
v1190#1.tdc63 dE1 p+n strip 47 TDC
v1190#1.tdc64 dE1 n+n strip 0 TDC
v1190#1.tdc79 dE1 n+n strip 15 TDC
v1190#1.tdc80 E1 p+n strip 0 TDC
v1190#1.tdc127 E1 p+n strip 47 TDC
v1190#2.tdc16 E1 n+n strip 0 TDC
v1190#2.tdc31 E1 n+n strip 15 TDC
v1190#2.tdc32 dE2 p+n strip 0 TDC
v1190#2.tdc79 dE2 p+n strip 47 TDC
v1190#2.tdc80 dE2 n+n strip 0 TDC
v1190#2.tdc95 dE2 n+n strip 15 TDC
v1190#2.tdc96 E2 p+n strip 0 TDC
v1190#3.tdc31 E2 p+n strip 47 TDC
v1190#3.tdc32 E2 n+n strip 0 TDC
v1190#3.tdc47 E2 n+n strip 15 TDC
v1190#3.tdc48 LEDA-0 strip 0 TDC
v1190#3.tdc63 LEDA-0 strip 15 TDC
v1190#2.tdc64 LEDA-1 strip 0 TDC
v1190#2.tdc79 LEDA-1 strip 15 TDC
v1190#3.tdc80 LEDA-2 strip 0 TDC
v1190#3.tdc95 LEDA-2 strip 15 TDC
v1190#3.tdc96 LEDA-3 strip 0 TDC
v1190#3.tdc111 LEDA-3 strip 15 TDC
v1190#3.tdc112 PIN photodiode 1 TDC
v1190#3.tdc113 PIN photodiode 2 TDC
v1190#3.tdc114 PIN photodiode 3 TDC
v1190#3.tdc115 PIN photodiode 4 TDC
|
Attachment 5: sort.f
|
*trigger
128
*oned
0..351 s 4096
*twod
*vars
*sort
C----67---------------------------------------------------------------72------80
SUBROUTINE init
IMPLICIT none
SAVE
C
C External functions
C
EXTERNAL dtime
C
INTEGER int, rshift, s2order
C
REAL dtime, float, rand
C
C Parameter variables
C
INTEGER maxadcs
PARAMETER (maxadcs = 2200)
INTEGER adcs_max
PARAMETER (adcs_max = 11*32)
INTEGER tdcs_max
PARAMETER (tdcs_max = 3*112)
INTEGER maxscalers
PARAMETER (maxscalers = 32)
INTEGER maxepics
PARAMETER (maxepics = 64)
INTEGER event_prescaler
PARAMETER (event_prescaler = 1000000)
INTEGER scaler_prescaler
PARAMETER (scaler_prescaler = 1000000)
INTEGER epics_prescaler
PARAMETER (epics_prescaler = 1000000)
C
LOGICAL csm
PARAMETER (csm = .true.)
C
C Local variables
C
INTEGER data(0:maxadcs-1), epics_counter, events, events_old, i
INTEGER*2 i2(2)
INTEGER i4, ierr, iflag, ireturn, j, k, m_adc, sc_counter, type
INTEGER w(0:31)
C
LOGICAL hit(0:maxadcs-1)
C
REAL c(0:31), gain(0:maxadcs-1), offset(0:maxadcs-1), r4, rate
REAL time(2)
C
C Namelists
C
NAMELIST /variables/ gain, offset, c, w
C
C Common variables
C
INTEGER*2 adc_data(0:maxadcs-1)
C
COMMON /fdata/ adc_data
C
C Common variables
C
INTEGER*2 adcs(0:maxadcs-1)
C
COMMON /fid/ adcs
C
C Common variables
C
INTEGER noadcs
C
COMMON /fmult/ noadcs
C
EQUIVALENCE ( i4, i2( 1 ) )
C
C----67---------------------------------------------------------------72------80
WRITE ( 6, * ) ' *** S1284 - sort - November 2013'
WRITE ( 6, * ) ' *** Entry init commences'
C Initialise arrays for unpacked event data.
DO i = 0, maxadcs - 1
data( i ) = 0
hit( i ) = .FALSE.
ENDDO
C Initialise gains/offsets
DO i = 0, maxadcs - 1
gain( i ) = 1.0
offset( i ) = 0.0
ENDDO
C Initialise constants/1D windows
DO i = 0, 31
c( i ) = 1.0
w( i ) = 0
ENDDO
C Initialise counters
sc_counter = 0
epics_counter = 0
events = 0
events_old = 0
C Read program variables via NAMELIST I/O
OPEN( 1, FILE = '',
+ IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** OPEN I/O error:', ierr
RETURN
ENDIF
READ( 1, NML = variables, IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** READ I/O error:', ierr
ENDIF
CLOSE( 1, IOSTAT = ierr )
IF ( ierr.NE.0 ) THEN
WRITE( 6, * ) ' *** CLOSE I/O error:', ierr
RETURN
ENDIF
C Display program variables
DO i = 0, adcs_max-1, 8
WRITE( 6, 9001 ) i, i+7, ( gain( j ), j = i, i+7 )
ENDDO
DO i = 0, adcs_max-1, 8
WRITE( 6, 9002 ) i, i+7, ( offset( j ), j = i, i+7 )
ENDDO
DO i = 1000, 1000+tdcs_max-1, 8
WRITE( 6, 9002 ) i, i+7, ( offset( j ), j = i, i+7 )
ENDDO
DO i = 0, 31, 8
WRITE( 6, 9003 ) i, i+7, ( c( j ), j = i, i+7 )
ENDDO
DO i = 0, 31, 8
WRITE( 6, 9004 ) i, i+7, ( w( j ), j = i, i+7 )
ENDDO
WRITE ( 6, * ) ' *** Entry init ends'
RETURN
C----67---------------------------------------------------------------72------80
ENTRY sortin
events = events + 1
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
rate = FLOAT( events - events_old ) / dtime(time)
WRITE( 6, * ) ' *** event:', events, ' (', rate,' events/s)'
events_old = events
ENDIF
C Convert Eurogam type 0 ID to (a more) logical channel number.
C ADC data channels 0-999
C TDC data channels 1000-1999
C Scaler data channels 2000-2099
C EPICS data channels 2100-2199
call egid2logical( noadcs, adcs, adc_data, type, csm )
C----67---------------------------------------------------------------72------80
C Event data.
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
WRITE( 6, * ) ' *** Packed event:', events, ' noadcs:', noadcs
DO i = 0, noadcs - 1
WRITE( 6, 9050 ) adcs( i ), adc_data( i )
ENDDO
ENDIF
C Unpack event data from packed data arrays.
DO i = 0, noadcs - 1
IF ( adcs( i ).GE.0 .AND. adcs( i ).LT.maxadcs ) THEN
data( adcs( i ) ) = adc_data( i )
hit( adcs( i ) ) = .TRUE.
ENDIF
ENDDO
IF ( MOD( events, event_prescaler ).EQ.0 ) THEN
WRITE( 6, * ) ' *** Unpacked event:', events
DO i = 0, adcs_max-1, 16
WRITE(6,9060) i, i+15, (data(j),hit(j),j=i,i+15)
ENDDO
DO i = 1000, 1000+tdcs_max-1, 16
WRITE(6,9060) i, i+15, (data(j),hit(j),j=i,i+15)
ENDDO
ENDIF
C----67---------------------------------------------------------------72------80
C Scaler data.
IF ( AND( X'00000002', type ).EQ.2 ) THEN
sc_counter = sc_counter + 1
C----67---------------------------------------------------------------72------80
C EPICS data.
ELSEIF ( AND( X'00000004', type ).EQ.4 ) THEN
epics_counter = epics_counter + 1
C----67---------------------------------------------------------------72------80
C Unexpected data type.
ELSEIF ( AND( X'00000008', type ).EQ.8 ) THEN
RETURN
C If event does not contain any ADC/TDC data return.
ELSEIF ( AND( X'00000001', type ).NE.1 ) THEN
RETURN
ENDIF
C----67---------------------------------------------------------------72------80
C Sort unpacked event data
m_adc = 0
C----67---------------------------------------------------------------72------80
C ADCs
DO i = 0, adcs_max-1
IF ( hit( i ) ) THEN
m_adc = m_adc + 1
ENDIF
ENDDO
c IF ( m_adc.GT.16 ) GOTO 1000
C IF ( m_adc.LT.16 ) GOTO 1000 ! use this line to get rid of alpha source
DO i = 0, adcs_max - 1
IF ( hit( i ) ) THEN
j = INT( c(0) * gain(i) * (data(i) - offset(i)) + rand(iflag) )
CALL inc1d( i, j )
ENDIF
ENDDO
C----67---------------------------------------------------------------72------80
C Re-initialise unpacked data arrays using the packed data arrays.
C Note: assumes packed data arrays are not modified by event.
1000 CONTINUE
DO i = 0, noadcs - 1
data( adcs( i ) ) = 0
hit( adcs( i ) ) = .FALSE.
ENDDO
RETURN
C----67---------------------------------------------------------------72------80
ENTRY finish
WRITE ( 6, * ) ' *** Entry finish '
RETURN
C----67---------------------------------------------------------------72------80
9001 FORMAT( ' gain(', i4, '-', i4, ')', 8f8.5 )
9002 FORMAT( ' offset(', i4, '-', i4, ')', 8f8.2 )
9003 FORMAT( ' c(', i4, '-', i4, ')', 8f8.3 )
9004 FORMAT( ' w(', i4, '-', i4, ')', 8i8 )
9010 FORMAT(/' *** scaler event: ', i10 )
9020 FORMAT( ' scaler(', i2, '-', i2, ')', 8(1x,i10) )
9030 FORMAT(/' *** epics event:', i10 )
9040 FORMAT( ' epics(', i2, '-', i2, ')', 8(1x,g13.6) )
9050 FORMAT( 2(1x,i4) )
9060 FORMAT( 2(1x,i4), 16(1x,i4,1x,l1) )
C----67---------------------------------------------------------------72------80
END
C----67---------------------------------------------------------------72------80
SUBROUTINE egid2logical( noadcs, adcs, adc_data, type, csm )
... 209 more lines ...
|
1
|
Tue Nov 26 14:16:54 2013 |
Naomi, Manuela, Diana, Mariangela | | General | alpha particle run screen shots | |
Attachment 1: S2_adc4.png
|
|
Attachment 2: Screenshot_78.png
|
|
Attachment 3: Screenshot_LEDA34.png
|
|
Attachment 4: Screenshot_LEDA56.png
|
|
Attachment 5: Screenshot_leda1-2.png
|
|
Attachment 6: s2_adc3.png
|
|
3
|
Fri Nov 29 18:20:08 2013 |
Naomi, Titti, Angelo | | | delE vs E spectrum | for run R54,55,56 spectrum number S4010 in sort3.f |
Attachment 1: 2013-11-29_17.15.42.jpg
|
|
|