Tuda logbooks General E1104 ISACII E1195 E1103 E1147 S1287 S1203 S1233 S1284 S1447 23Na(a,p) S1540 S1381  S1847 Catania
  S1233  ELOG logo
Message ID: 8     Entry time: Thu Dec 6 20:28:23 2012
Author: Naomi Galinski 
Type:  
Category:  
Subject: DAQ configuration 

 VME crate (master): VME V430 

1x MVME2431 VME processor module, slot 1

1x SBS master, slot 2

1x SAC S9418 ACQ controller, slot 5 - trigger condition set here

14x Silena 9418 ADC, slot 7-10 (geographic location doesn't matter only jumper address)

 

VME crate (slave): VME430 - we didn't use this since the power supply died but we still needed a VME crate connected to the master crate

1x SBS slave, slot 1 (needs to be plugged in!)

2x CAEN V560 scalers

4x CAEN V1190 TDC

 

Debugging notes:

Turn slave crates on first and master crate last

VME crates must be of type V430 for MIDAS UK. We used V64x crates and unable to read scaler and TDC modules. Error messages result if you try to load modules in the wrong type caret into MIDAS UK. 

HOWEVER, SBS modules MUST be plugged in. Probably some firmware coding in MVME2431 tells MIDAS there are two VME crates. SIGBUS error results if slave crate is not connected to the master crate.

ELOG V2.9.2-2455