Friday, March 01, 2019, 14:50:
SV5 replaced with a new valve.
SV1 disconnected from the He line and linked to the mini pump line.
Tuesday, March 05, 2019, 08:05: Roughing.
Tuesday, March 05, 2019, 08:36: Turbo pumps on.
Tuesday, March 05, 2019, 10:03: Vacuum at 1.30e-05T
Open SV3 & SV4. Vacuum remains unchanged. No response on the RGA.
Tuesday, March 05, 2019, 10:05: SV1 opened & closed. Responds well.
Tuesday, March 05, 2019, 10:06: Mini-pump on. MP manual valve closed.
Tuesday, March 05, 2019, 10:17: MP manual valve opened. No response on RGA. Vacuum stable / going down @ 1.13e-05T.
Tuesday, March 05, 2019, 10:25: SV1 open. No response on RGA. Vacuum stable / going down @ 1.02e-05T.
Tuesday, March 05, 2019, 10:35: SV1, SV3, SV4 closed. SV5 opened / closed. Minor response on RGA & Vacuum.
Tuesday, March 05, 2019, 10:40: SV5 opened fully to pump down.
Tuesday, March 05, 2019, 10:42: SV3 & SV4 opened fully to pump down.
Tuesday, March 05, 2019, 12:56: SV5 closed.
Tuesday, March 05, 2019, 12:57: SV3 & SV4 closed.
Tuesday, March 05, 2019, 12:59: SV1 to mini pump opened.
Tuesday, March 05, 2019, 13:06: SV3 & SV4 opened.
Tuesday, March 05, 2019, 13:27: SV1 closed. SV5 opened / closed in 'quick bursts'
Tuesday, March 05, 2019, 13:31: SV5 fully opened.
Tuesday, March 05, 2019, 13:43: Mini pump off.
Wednesday, March 06, 2019, 07:56: Mini-pump on. TS locked up. Power on. Gas lines open.
Wednesday, March 06, 2019, 07:59: RGA reset.
Wednesday, March 06, 2019, 08:00: Sources & optics on.
Wednesday, March 06, 2019, 08:02: Auto-ramping TGHT / TBHT to 100 / 75 A @ 2A per min.
Wednesday, March 06, 2019, 08:07: BIAS / EZL / EE @ 10 / 5 / 0.5 kV - Low settings stable.
Wednesday, March 06, 2019, 08:19: IV4 opened.
Wednesday, March 06, 2019, 11:05: SV3 closed.
Wednesday, March 06, 2019, 11:10: SV4 & SV5 closed.
Wednesday, March 06, 2019, 11:11: SV5 re-opened.
Wednesday, March 06, 2019, 11:15: SV5 closed.
Wednesday, March 06, 2019, 11:16: SV1 to mini pump (running) opened.
Wednesday, March 06, 2019, 11:22: Sv3 & SV4 opened. No response on vacuum or RGA. SV5 good.
Wednesday, March 06, 2019, 11:30: Closed SV1, SV3, & SV4. open / close SV5 until stable.
Wednesday, March 06, 2019, 11:33: SV3 & SV4 opened.
Wednesday, March 06, 2019, 11:36: SV5 fully opened. No trip.
Wednesday, March 06, 2019, 11:40: Auto-ramping TGHT / TBHT to 350 / 250 A @ 2A per min.
Thursday, March 07, 2019, 07:23: Auto-ramping TGHT / TBHT to 580 / 290 A @ 2A per min.
Thursday, March 07, 2019, 07:28: BIAS / EZL / EE @ 30 / 13 / 1.5 kV. Anode 200 V
Thursday, March 07, 2019, 07:38: Something in the BIAS went horribly wrong. The Test Stand was crackling like a fire cracker. Very loud.
BIAS / EZL / EE / Anode off. Begin auto cooling.
Optics tripped. TMS:TP6 tripped

|