Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production, Page 1 of 7  Not logged in ELOG logo
  ID Date Author Target/No.# Source Stationdown Module Target Oven W.O# Heat Shield W.O# Status Subject Text Attachments
  7   Friday, June 03, 2011, 09:16 John WongTa#37LP-SISITWTM138634-536833-7SpentTarget is done Fri Jun  3 12:40:30 2011
Ta#37-LP-SIS (w.o#38634-5)
Filled with 400 Ta foils (25/pk),
 EE.JPGEE-CuO.jpg 
  13   Tuesday, August 09, 2011, 14:31 John WongUCx#2LP-SISITWTM138634-838633-5SpentUCx#2 run is finished.UCx#2 Spec:
Target wrapped with 3 Ta-heat shields
Target length = 11.2cm
 broke_screwhead.jpgUCx#2.jpg 
  18   Wednesday, November 16, 2011, 14:08 John WongUCx#3LP-SISITWTM138634-1036833-3SpentUCx#3 ready to go online Wednesday, November 16, 2011, 13:51
UCx#3 descriptions: 
Target oven wrapped with 3-Ta heat
 UCx#3_assembly.jpg 
  19   Monday, February 13, 2012, 16:00 John WongNb#6LP-SISITWTM138634-436833-1SpentNb#5 ready in the Conditioning Station 

Monday, February 13, 2012,
16:00 
  
  22   Friday, June 01, 2012, 11:43 John WongTa#38LP-SISITWTM139165-238633-2SpentTa#38 target descriptionTa#38 LP-SIS target description: 
Total Ta foils = 400
Foil thickness = 0.025mm
 Ta_38_EE_deposit.JPGTa#38_EE.PNGTa#38_CE.PNG 
  23   Monday, June 11, 2012, 13:46 John WongNb#6LP-SISITWTM138634-436833-1SpentNb#5 run finished

    

       
            
  
  25   Friday, July 20, 2012, 11:39 John WongUCx#4LP-SISITWTM138634-936833-4SpentUCx#4 target descriptionFriday, July 20, 2012, 11:35
UCx#4 target description, see attachment#1
The target is assembled and stored
 UCx#4_specfications.PNG 
  27   Wednesday, August 29, 2012, 14:52 John WongUCx#5LP-SISITWTM439165-5 FailedUCx#5 target description Wednesday, August 29, 2012, 14:50
UCx#5 target description, see attachment#1
The target is currently undergoing
 UCx#5_specifications.PNG 
  30   Tuesday, December 11, 2012, 15:44 Anders MjosSiCHP-FEBIADITWTM4nana (old style fittings)ReadyTest target for the Conditioning Station The target has been used for operator
training previously at the ISAC Test Stand.

    9-pin connector was completed
  
  32   Thursday, April 11, 2013, 14:30 John WongTa#39LP-SISITWTM139165-7 SpentTa#39 target descriptionTa#38 LP-SIS target description:
Total Ta foils = 400
Foil Thickness = 0.025mm
  
  35   Friday, August 30, 2013, 12:08 John WongUCx#7LP-SISITWTM138634-739230-4SpentUCx#7 - target descriptionFriday, August 30, 2013, 12:06
UCx#7 target specification, see attachment
#1.
 UCx#7_specifications.PNG 
  37   Friday, October 25, 2013, 17:35 John WongTa#41HP-SISITWTM438817-10 SpentTa#41 target descriptionFriday, October 25, 2013, 17:35
Ta#41 HP-SIS target description:
Total Ta foils = 400
  
  39   Monday, March 17, 2014, 16:15 John WongTa#42LP-SISITWTM440282-139956-1SpentTa#42 Target description Monday, March 17, 2014, 16:14
Ta#42 LP-SIS target description:
Total Ta foils = 400
  
  43   Tuesday, July 15, 2014, 10:54 Laura LambertTa # 43LP-SISITWTM140282-2 ReadyTa # 43 Target Description Tuesday, July 15, 2014, 9:45
Ta#42 LP-SIS target description:
  
  45   Monday, July 28, 2014, 15:57 John WongZrC#6LP-SISITWTM140282-3 SpentZrC target description  Monday, July 28, 2014, 15:52
See attachment#1 for ZrC target description. 
Target is currently undergoing the
 ZrC#6.JPG 
  50   Friday, April 17, 2015, 16:00 Laura LambertUCx # 12LP-SISITWTM141177-2 ReadyUCx#12 Target Description Thursday, April 16, 2015, 14:07
See attachment for target description
 UCx_12_target_description.PNG 
  52   Wednesday, June 03, 2015, 10:55 Laura LambertZrC#7LP-SISITWTM241177-1 ReadyZrC#7 target description  Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
 target_production_elog_ZrC#7.JPGZrC#7_final_density.xlsx 
  53   Monday, July 06, 2015, 12:18 John WongZrC#7LP-SISITWTM241177-1 FailedZrC#7 target description

    

       
            
  
  54   Tuesday, July 07, 2015, 13:00 John WongZrC#7LP-SISITWTM241177-2 ReadyZrC#7 (backup1) target descriptionTuesday, July 07, 2015, 12:36 
Total no. discs = 422
Total packed length = 13.2 cm (measured
 ZrC#7_backup.PNGZrC_specification_(backup#1_WO#41177-2).xlsx 
  60   Friday, March 04, 2016, 14:57 Laura LambertUCx#15LP-SISITW 41077-1 ReadyUCx#15 Target Description Friday, March 04, 2016, 14:56
Attached please find the UCx#15
 UCx_15_description.jpg 
ELOG V2.9.2-2455