ID |
Date |
Author |
Target/No.# |
Source |
Station |
Module |
Target Oven W.O# |
Heat Shield W.O# |
Status |
Subject |
|
112
|
Wednesday, September 29, 2021, 10:37 |
Darwin Ortiz Rosales | UCx#35 | LP-IG-LIS | | | 42218-5 | | Ready | UCx#35-Target_description |
Target ID |
UCx#35 |
General |
Total No. Discs |
179 |
|
Disc area |
0.95 |
cm2 |
Ave graphite foil thickness/disc |
0.013 |
cm |
Ave. graphite foil mass/disc |
0.015 |
g |
|
Total mass of discs |
14.97 |
g |
Green Target |
Total Green mass of discs |
13.89 |
g |
Ave. mass/disc |
0.084 |
g |
Ave. mass/disc (no C-foil & org) |
0.078 |
g |
Ave. thickness/disc (no C-foil) |
0.037 |
cm |
Theoretical length (with C-foil) |
9.0 |
cm |
Total packed length (with C-foil) |
10.0 |
cm |
Final Target |
UC2 in Target |
11.05 |
g |
Free C in Target |
0.83 |
g |
Total massUC2+free C |
11.88 |
g |
U mass |
10.04 |
g |
U thickness |
10.56 |
g/cm2 |
UC2 bulk density (measured) |
2.88 |
g/cm3 |
Theoretical Density |
8.24 |
g/cm3 |
% Yield Density |
34.91 |
% |
Theoretical Porosity |
0.651 |
|
|
Attachment 1: UCx#35_Target_Description_.png
|
|
|
111
|
Tuesday, September 21, 2021, 21:08 |
Darwin Ortiz Rosales | C#3 | LP-SIS | | | 44691-7 | | Ready | Target C #3 Description |
Tuesday, September 21, 2021, 21:09
See attached file for target description. |
Attachment 1: C#3_Target_description.png
|
|
|
110
|
Monday, September 13, 2021, 14:53 |
Darwin Ortiz Rosales | SiC#41 | HP-SIS | | | 42218-7 | | Ready | Target SiC#41 Description |
Monday, September 13, 2021, 14:52

|
Attachment 1: Screenshot_2021-09-13_144830.png
|
|
|
109
|
Monday, August 16, 2021, 11:02 |
John Wong | UCx#34 | LP-SIS | ITW | TM2 | 44691-5 | 44378-1 | Ready | Target description |
Monday, August 16, 2021, 11:01
See attachments for the target description and SEM images
|
Attachment 1: UCx#34_target_description.PNG
|
|
Attachment 2: UCx_34_SEM_Density_Measurements.pdf
|
|
|
108
|
Wednesday, June 23, 2021, 18:13 |
Aaron Schmidt | Ta#62 | LP-SIS | ITE | TM4 | 44691-4 | | In progress | Ta#62 Target Description (2) |
Ta#62 LP-SIS target description: (REPLACEMENT FOR 44139-10)
Total Ta foils = 470 [6x20 packs + 350 single discs]
Foil Thickness = 0.025mm
Target density = 14.29 g/cm3
Target length = 3.4 cm
Total Mass = 48.602 g [Incl foils + Ta wire on 6 packs]
Total mass w/ Target oven= 456 g (w/ end caps)
Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack
End caps installed (Not expanded). No Ta foil heat shield added |
|
107
|
Wednesday, June 09, 2021, 11:45 |
Darwin Ortiz Rosales | UCx#33 | LP-SIS | | | 44139-12 | | Ready | UCx#33-Target_description |
Cartridge with discs was further heated in EVAP1 (eLog 271 Evaporator 1). |
Attachment 1: UCx33-target_description.png
|
|
|
106
|
Thursday, April 08, 2021, 09:54 |
Aaron Schmidt | Ta#62 | LP-SIS | | | 44139-10 | | Ready | Ta#62 target description |
Ta#62 LP-SIS target description:
Total Ta foils = 470 [6x20 packs + 350 single discs]
Foil Thickness = 0.025mm
Target density = 13.96 g/cm3
Target length = 3.4 cm
Total Mass = 47.461 g [Incl foils + Ta wire on 6 packs]
Total mass w/ Target oven= 445 g (w/ end caps)
Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack
End caps installed (expanded). No Ta foil heat shield added |
|
105
|
Tuesday, March 16, 2021, 17:05 |
Luca Egoriti | ITE-TM4-UC#32-P2N-SIS | HP-SIS | ITE | TM4 | - | - | In progress | UO2 discs cutting |
This afternoon, Darwin prepared in the hot lab fume hood the two UO2 slurries to be cut into P2N target discs. Later, I took over cutting both slurries. A total of 49 annular discs were cut and loaded into the P2N graphite container.
The discs thickness was measured by stacking 5 discs on each other, and measuring their thickness in two points.
#discs = 49
Average disc thickness = 0.453mm
Empty cartridge weight = 9.42 g
Full cartridge weight = 39.86 g
UO2+C weight = 30.44 g
The unused material plus the cutting scrap were left in a zip lock bag on a shelf in the right hand side of the fume hood. The center scraps and the loaded target were placed in a plastic tray on the top shelf. The used tools and scales were left on the right of the working area, the napkins on the bottom were put into the garbage bag (inside the fume hood) and replaced, while the only napkin left is the one with the target information (recorded in attached picture). |
Attachment 1: UC32-P2N_material_info.jpg
|
|
Attachment 2: Fume_hood.jpg
|
|
|
104
|
Thursday, November 12, 2020, 11:32 |
Darwin Ortiz Rosales | UCx#31 | HP-SIS | ITE | TM4 | 44160 | 43822 | Ready | UCx#31-Target_description |
Target full name ITE-TM4-UC#31-P2N-SIS
|
Attachment 1: UCx31-target_description.png
|
|
|
103
|
Tuesday, October 27, 2020, 12:53 |
Aaron Schmidt | Nb#9 | LP-SIS | ITE | TM4 | 44508-2 | | Ready | Nb#9 LP-SIS target description |
Nb#9 LP-SIS target description:
Total Ta foils = 470 [6x20 packs + 350 single discs]
Foil Thickness = 0.025mm
Target density = 7.24 g/cm3
Target length = 3.5 cm
Total Mass = 25.343 g [Incl foils + Ta wire on 6 packs]
Total mass w/ Target oven= 425 g (w/ end caps)
Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack |
Attachment 1: Nb#9_Target_Loading_data.pdf
|
|
|
102
|
Tuesday, October 06, 2020, 14:25 |
Aaron Schmidt | Ta#61 | LP-SIS | ITE | TM4 | 44508-1 | | In progress | Ta#61 Target Description |
Ta#61 LP-SIS target description:
Total Ta foils = 470 [6x20 packs + 350 single discs]
Foil Thickness = 0.025mm
Target density = 12.76 g/cm3
Target length = 3.4 cm
Total Mass = 43.388 g [Incl foils + Ta wire on 6 packs]
Total mass w/ Target oven= 464 g (w/ end caps)
Discs in target are arranged as follows: 1pack / 100 singles / 1pack / 75 singles / 2packs / 75 singles / 1pack / 100 singles / 1pack
End caps installed (not yet expanded). No Ta foil heat shield added |
|
101
|
Tuesday, September 29, 2020, 11:50 |
Marla Cervantes | C#2 | LP-SIS | ITW | TM2 | 44139-9 | | In progress | Target C#2 Description |
Tuesday, September 29, 2020, 11:49
See attached picture for description |
Attachment 1: C2-Description.JPG
|
|
|
100
|
Thursday, June 04, 2020, 15:00 |
Marla Cervantes | C#1 | LP-SIS | | | 43044-8 | | In progress | Target C#1 Description |
Thursday, June 04, 2020, 15:00
See attached picture for description |
Attachment 1: C1-Description.PNG
|
|
|
99
|
Wednesday, April 15, 2020, 08:10 |
Darwin Ortiz Rosales | SiC#40 | HP-SIS | | | 42218-8 | | Ready | Target SiC#40 Description |
Wednesday, April 15, 2020, 07:51
See attached picture for description |
Attachment 1: Annotation_2020-04-15_080836.png
|
|
|
98
|
Thursday, February 20, 2020, 08:11 |
Aaron Schmidt | Ta#60 | LP-SIS | | | 44139-13 | | Ready | Ta#60 Target Description |
Thursday, February 20, 2020, 08:07:
Ta#60 LP-SIS target description:
Total Ta foils = 470 [6x20 packs + 350 single discs]
Foil Thickness = 0.025mm
Target density = 14.081 g/cm3
Target length = 3.33 cm
Total Mass = 46.891 g [Incl foils + Ta wire on 6 packs]
Total mass w/ Target oven= 445g w/ end caps)
Discs in target are arranged as follows: 1pack / 75singles / 1pack / 100singles / 2packs / 100singles / 1pack / 75singles / 1pack
End caps installed (Expanded). No Ta heat shield added. |
Attachment 1: Ta#60_Loading_Data.pdf
|
|
|
97
|
Friday, November 29, 2019, 10:53 |
Darwin Ortiz Rosales | SiC#39 | HP-FEBIAD | | TM2 | 42464-3 | | Ready | Target SiC#39 Description |
Friday, December 06, 2019, 15:34
Added SEM images (see attachment#2) - JW
|
Attachment 1: SiC#39_description.PNG
|
|
Attachment 2: SiC39_SEM.pdf
|
|
|
96
|
Tuesday, November 19, 2019, 12:20 |
Darwin Ortiz Rosales | UCx#30 | LP-SIS | | | 44062-3 | | Ready | UCx30-target_description |
|
Attachment 1: UCx#30.PNG
|
|
Attachment 2: UCx30-taret_description_revised.png
|
|
|
95
|
Monday, October 21, 2019, 12:38 |
Darwin Ortiz Rosales | UCx#29 | LP-SIS | | | 44062-6 | | Ready | UCx29-target_description |
|
Attachment 1: UCx#29.PNG
|
|
|
94
|
Friday, October 11, 2019, 09:26 |
Darwin Ortiz Rosales | SiC#38 | HP-FEBIAD | | TM2 | 42464-4 | | Ready | Target SiC#38 Description |
Friday, October 11, 2019, 09:25
See attached picture for description.
|
Attachment 1: SiC#38.PNG
|
|
|
93
|
Wednesday, October 02, 2019, 11:18 |
Marla Cervantes | UCx#28 | LP-SIS | | | 44062-4 | | Ready | UCx #28 Target description |
Wednesday, October 02, 2019, 11:17
Attached please find the UCx#28 target description. |
Attachment 1: UCx28-target_description.JPG
|
|