Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 54     Entry time: Tuesday, July 07, 2015, 13:00
Author: John Wong 
Target/No.#: ZrC#7 
Source: LP-SIS 
Station: ITW 
Module: TM2 
Target Oven W.O#: 41177-2 
Heat Shield W.O#:  
Status: Ready 
Subject: ZrC#7 (backup1) target description 

Tuesday, July 07, 2015, 12:36 

Total no. discs = 422

Total packed length = 13.2 cm (measured after the sintering process) 

Note:  The theoretical length (ZrC + graphite foils) is 10.52cm    After the sintering process, the stack of discs expanded in length.  To avoid crushing the materials while inserting the endcaps, the discs are gentally packed to 13.2cm.

(see attachments for more details)


 

Attachment 1: ZrC#7_backup.PNG  14 kB  | Hide | Hide all
ZrC#7_backup.PNG
Attachment 2: ZrC_specification_(backup#1_WO#41177-2).xlsx  11 kB
ELOG V2.9.2-2455