Subject: Broken M20BB Bearing Removed, New Design Complete 

 The broken M20 beam blocker plastic shaft bearing was removed.  Measurements of the bearing as well as the shielding disc (for which drawings can't be found) were taken inside the hot cell and a brass replacement bearing has been designed based on these measurements.

Photos of the removed bearing, measured dimensions of bearing and shielding disc, and a PDF drawing of the new design are attached.

Attachment 1: P1010779.JPG  182 kB  | Show | Hide all
Attachment 2: P1010778.JPG  153 kB  | Show | Hide all
Attachment 3: P1010781.JPG  214 kB  | Hide | Hide all
P1010781.JPG
Attachment 4: M20BB_Split_Flange_Shaft_Bearing.PDF  129 kB  | Show | Hide all
ELOG V2.9.2-2455