Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Meson Hall  Not logged in ELOG logo
Message ID: 11     Entry time: Wednesday, January 18, 2012, 12:01
Author: Isaac Earle 
Category: Repair 
Type: Target 2 
Specific: Target 
Subject: Broken M20BB Bearing Removed, New Design Complete 

 The broken M20 beam blocker plastic shaft bearing was removed.  Measurements of the bearing as well as the shielding disc (for which drawings can't be found) were taken inside the hot cell and a brass replacement bearing has been designed based on these measurements.

Photos of the removed bearing, measured dimensions of bearing and shielding disc, and a PDF drawing of the new design are attached.

Attachment 1: P1010779.JPG  182 kB  | Show | Hide all
Attachment 2: P1010778.JPG  153 kB  | Show | Hide all
Attachment 3: P1010781.JPG  214 kB  | Show | Hide all
Attachment 4: M20BB_Split_Flange_Shaft_Bearing.PDF  129 kB  | Show | Hide all
ELOG V2.9.2-2455