Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC, Page 10 of 140  Not logged in ELOG logo
ID Date Author Category Type Moduledown Target/Number Subject
  581   Monday, January 20, 2014, 13:35 David WangITEStandard OperationTM4 5 shielding blocks had been moved out of ITE

5 SHIELDING BLOCKS HAD BEEN MOVED OUT OF ITE.AIR SAMPLE AND SWIPED FIRST BLOCK AND ITE PIT.NOTHING HAD BEEN FOUND ON ALPHA MONITOR AND OTHER TWO MONITORS.

  582   Monday, January 20, 2014, 13:38 David WangITEStandard OperationTM4 DISCONNECTED TM4 IN ITE.

I DISCONNECTED TM4 IN ITE. ALL WATER LINES HAD BEEN PURGED OUT WITH PRESSURE AIR.

  584   Monday, January 20, 2014, 14:37 Travis CaveITEStandard OperationTM4UC#8module move

TM#4 with UC#8 has been moved from the east target station to the south hot cell.

  585   Tuesday, January 21, 2014, 14:32 Travis CaveSouth Hot-CellStandard OperationTM4no targetmodule move

TM#4 has been moved from the south hot cell to the north west silo.

  619   Wednesday, March 12, 2014, 09:45 Travis CaveITWStandard OperationTM4no targetmodule move

TM#4 has been moved from the north west silo to the west target station.

  621   Thursday, March 13, 2014, 07:35 David WangITWStandard OperationTM4 TM4 and ITW turbo pumps have been started

I connected ITW  vacuum system to TM4. TM4 and ITW turbo pumps have been started successfully. The pumping down is good so far.

  625   Wednesday, March 19, 2014, 15:46 David WangITWStandard OperationTM4 TM4 and ITE air to vacuum leak check and TM4 water lines helium test.

With TM4 located in ITW, All air to vacuum seals  on ITW primary and secondary vacuum vessels have been leak  checked with leak detector hooked directly onto the TM4 service cap.The base LR :00xE-9atm.cc/sec. The ITW IG1 was 1.16xE-6 torr which was good. No leak has been found during the checking.Also, the TM4 water lines(except HS) had been  pressurized with 70 psi helium on each for 2 minutes. There was no response during the test. The ITW and TM4 are good on leak checking.See attachment pictures

Attachment 1: 001.JPG
001.JPG
Attachment 2: 002.JPG
002.JPG
Attachment 3: 003.JPG
003.JPG
Attachment 4: 004.JPG
004.JPG
Attachment 5: 005.JPG
005.JPG
Attachment 6: 008.JPG
008.JPG
Attachment 7: 012.JPG
012.JPG
  629   Monday, March 24, 2014, 12:01 Travis CaveITWStandard OperationTM4no targetmodule move

TM#4 has been moved from the west target station to the south hot cell.

  630   Tuesday, March 25, 2014, 09:11 chad fisherSouth Hot-CellStandard OperationTM4Ta#42Ta#42 install and "new" 9 pin

Ta#42 has been installed onto TM4. The "new" 9 pin connector was not an issue...attually went on better than any other previous one. Leaving the mounting screws loose on the target half allowed use of the manipulator to center the pins and insert them with ease.

Attachment 1: TM4_20140325_01.jpg
TM4_20140325_01.jpg
  631   Tuesday, March 25, 2014, 13:29 Travis CaveSouth Hot-CellStandard OperationTM4Ta#42Electrical check

TM#4 was checked electrically with and without target on it, see attached PDFs for details.

Attachment 1: TM#4_notarget_electest_SHC.PDF
TM#4_notarget_electest_SHC.PDF
Attachment 2: TM#4_Ta42surf_electest_SHC.PDF
TM#4_Ta42surf_electest_SHC.PDF
  632   Wednesday, March 26, 2014, 06:57 David WangSouth Hot-CellStandard OperationTM4Ta#42Leak check on TM4 HS water line with new Ta #42 target.

Chad and I leak checked TM4 HS line with Ta#42 target on the module. The leak detector base LR 0.0xE-9 atm.cc/sec, base pressure0.0xE-4 torr. Chad applied helium to the joints, and flushed the helium around the target. No leak has been found.I will do helium pressure test on this circuit at CS later.

  633   Wednesday, March 26, 2014, 08:36 Travis CaveConditioning StationStandard OperationTM4Ta#42module move

TM#4 with Ta#42 has been moved from the south hot cell to the conditioning station.

  634   Thursday, March 27, 2014, 10:47 Travis CaveConditioning StationStandard OperationTM4Ta#42Electrical check

TM#4 with Ta#42 in the conditioning station under vacuum electrical check.

Attachment 1: TM#4_Ta42surf_electest_CS.PDF
TM#4_Ta42surf_electest_CS.PDF
  635   Monday, March 31, 2014, 13:22 Bevan MossConditioning StationStandard OperationTM4Ta #42HV conditioning

 TM4 with Ta#42 was HV conditioned to 35kV with the optics tray at 17.5kV. There was some vacuum response while ramping but well within normal. Attached is a screen shot and the associated data.

Attachment 1: 31032014_TM4_Ta#42_HV_Conditioning.txt
Time	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	TCS:IG1:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:DIC1:RDCOND [Mohm]	
03/31/2014 10:01:03.733174	                            11.44                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:04.732844	                            11.44                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:05.732769	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:06.732712	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:07.732465	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:08.733393	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:09.733515	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:10.734113	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:11.733990	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:12.733856	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:13.734748	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:14.734630	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:15.734460	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:16.734336	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:17.734235	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:18.735107	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:19.734959	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:20.734835	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:21.734750	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:22.844126	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:23.844486	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:24.844315	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:25.846185	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:26.846055	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:27.845938	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:28.846887	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:29.846712	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:30.846596	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:31.846538	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:32.846330	                            10.29                             0.30                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:33.847382	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:34.847056	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:35.846932	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:36.846800	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:37.846673	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:38.847547	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:40.104731	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:41.104567	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:42.104172	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:43.104164	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:44.104890	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:45.104770	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:46.104674	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:47.105620	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:48.106416	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:49.107534	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:50.107142	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:51.107016	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:52.106907	                            11.44                             0.18                             6.71                             0.01                      0.000000541                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:53.106824	                            11.44                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:54.106672	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:55.106512	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:56.106402	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:57.106261	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:58.106140	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:59.106045	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:00.105877	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:01.106805	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:02.106632	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:03.106782	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:04.107410	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:05.107394	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:06.108182	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:07.108063	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:08.107895	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:09.145507	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:10.195928	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:11.195508	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:12.195358	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:13.195230	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:14.196116	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:15.195989	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:16.195944	                            12.58                             0.18                             6.71                             0.01                      0.000000541                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:17.195738	                            12.58                             0.18                             6.71                             0.01                      0.000000541                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:18.195693	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:19.196508	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:20.196434	                            12.58                             0.18                             7.32                             0.01                      0.000000535                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:21.196308	                            12.58                             0.18                             7.32                             0.01                      0.000000535                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:22.196100	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:23.196019	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:24.283661	                            12.58                             0.18                             7.32                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:25.283865	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:26.283648	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:27.284460	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:28.284342	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002593                           BadVal
03/31/2014 10:02:29.285208	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001384                      0.000002571                           BadVal
03/31/2014 10:02:30.285140	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:31.285014	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:32.285861	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:33.285706	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:34.284790	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:35.285462	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:36.285355	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:37.286202	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:38.286087	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:39.287229	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:40.286833	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:41.286722	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:42.286663	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:43.286636	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:44.286345	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:45.287322	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:46.287072	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:47.286970	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:48.286830	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                           BadVal
03/31/2014 10:02:49.286701	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:52.177616	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:53.178236	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:54.179135	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:55.178964	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:56.182883	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                           BadVal
03/31/2014 10:02:57.183765	                            12.58                             0.18                             6.71                             0.01                      0.000000532                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:58.183585	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:02:59.183583	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:00.183372	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:01.183341	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:02.183147	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:03.182950	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:04.183824	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:05.183703	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:06.183578	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:07.184451	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:08.184426	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:09.185200	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:10.185094	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:11.184972	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:12.184928	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:13.214901	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:14.215641	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:15.215439	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:16.215466	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:17.216192	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:18.216066	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:19.216939	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:20.216993	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:21.216687	                            12.58                             0.18                             6.71                             0.01                      0.000000532                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:22.216602	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:23.216432	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:24.217344	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:25.218233	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:26.218061	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002549                             10.5
03/31/2014 10:03:27.217964	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:28.217956	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:29.217839	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:30.217602	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:31.217432	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:32.217311	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:33.217306	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:34.218096	                            11.44                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:35.217929	                            11.44                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:36.217843	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:37.279743	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:38.374264	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:39.455103	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:40.455295	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:41.455156	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:42.455022	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002549                             10.5
03/31/2014 10:03:43.517929	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:44.605664	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:45.605769	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:46.605499	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002549                             10.5
03/31/2014 10:03:47.605372	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:48.605280	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:49.606125	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:50.606000	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:51.606922	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:52.606757	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:53.606653	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:54.606492	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:55.606422	                            12.58                             0.18                             6.71                             0.01                      0.000000552                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:56.606253	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:57.606119	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001362                      0.000002615                             10.5
03/31/2014 10:03:58.606091	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002615                             10.5
03/31/2014 10:03:59.605889	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:00.605762	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:01.605614	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:02.605686	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:03.605398	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:04.605227	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:05.605108	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:06.604986	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:07.604864	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:08.604798	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:09.604612	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:10.604484	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:11.604377	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:12.604230	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:04:13.605097	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:14.604980	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:15.604853	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:16.604721	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:17.604603	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:18.604509	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:04:19.604351	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:20.604276	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:21.604146	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:22.605062	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:23.605929	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:24.605722	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001318                      0.000002593                             10.6
03/31/2014 10:04:25.605584	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:26.605468	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:27.616984	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:28.687685	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:29.688084	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:30.687958	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:31.809569	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001384                      0.000002593                             10.5
03/31/2014 10:04:32.809729	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:33.810786	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:34.810438	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:04:35.810414	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:04:36.810188	                            12.58                             0.18                             7.32                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:37.810076	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:38.867466	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:39.867804	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:40.886721	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:41.886686	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:42.886424	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:43.886328	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:44.886195	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:45.886102	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:46.885922	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:47.885880	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:48.886695	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.6
03/31/2014 10:04:49.886538	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002615                             10.5
03/31/2014 10:04:50.886467	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:51.886293	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002571                             10.5
03/31/2014 10:04:52.886184	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002615                             10.5
03/31/2014 10:04:53.886085	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:54.885916	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:55.980009	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:56.979253	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:57.978525	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:58.979433	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:59.979273	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:02.606530	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.6
03/31/2014 10:05:03.605880	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.6
03/31/2014 10:05:04.606708	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:05.606566	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:06.606480	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:07.606317	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:08.606192	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:09.889941	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:05:11.695372	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.6
03/31/2014 10:05:12.695678	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:13.743535	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:14.743435	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:15.743296	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:16.743524	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002549                             10.5
03/31/2014 10:05:17.743098	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:18.742924	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:19.742047	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:20.741695	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:21.741602	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:22.741410	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:05:23.741280	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:24.918398	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:25.918067	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:26.918881	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:27.918765	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:28.919631	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:29.919633	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:30.920406	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:31.920261	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:34.936859	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:35.936943	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.6
03/31/2014 10:05:36.937848	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:37.938715	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:38.938410	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:39.939247	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:40.939284	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:41.939003	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:05:42.938877	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:43.938828	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:44.938728	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:45.938504	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:46.938451	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:47.938375	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:48.938143	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:49.939010	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002615                             10.5
03/31/2014 10:05:50.938898	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:51.938765	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:52.938622	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.5
03/31/2014 10:05:53.938500	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:54.939556	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:55.939244	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:56.939118	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:57.939019	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:58.938910	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002549                             10.5
03/31/2014 10:05:59.938928	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:06:00.938613	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:01.938487	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:06:02.938362	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:03.938273	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:04.938225	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:05.937985	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:06.937870	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:07.937756	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002549                             10.5
03/31/2014 10:06:08.937630	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:06:09.937472	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
... 11454 more lines ...
Attachment 2: 31032014_Ta#42_HV_conditioning.JPG
31032014_Ta#42_HV_conditioning.JPG
  636   Wednesday, April 02, 2014, 09:14 Travis CaveITWStandard OperationTM4Ta#42module move

TM#4 with Ta#42 has been moved to the west target station.

  666   Tuesday, May 27, 2014, 10:42 Travis CaveITWStandard OperationTM4Ta#42module move

TM#4 with Ta#42 has been moved from  the west target station to the south hot cell.

  667   Tuesday, May 27, 2014, 11:45 Travis CaveSouth Hot-CellStandard OperationTM4Ta#42Electrical check

TM#4 electrical check with Ta#42 attached post beam at the south hot cell.

Attachment 1: TM4_Ta42_elec_chk_SHC_postbeam.PDF
TM4_Ta42_elec_chk_SHC_postbeam.PDF
  668   Wednesday, May 28, 2014, 08:48 Travis CaveSouth Hot-CellStandard OperationTM4no targetmodule move

TM#4 with no target has been moved from the south hot cell to the south west silo.

  725   Thursday, August 07, 2014, 10:45 Travis CaveSouth Hot-CellStandard OperationTM4no targetmodule move

TM#4 has been moved from the south west silo to the south hot cell.

  726   Thursday, August 07, 2014, 13:58 David WangSouth Hot-CellStandard OperationTM4UCx #10Leak check on TM4 HS water line with new UCX target.

Isaac and I leak checked TM4 HS line with new UCX target. The leak detector base LR 0.0xE-9 atm.cc/sec, base pressure0.0xE-4torr. Isaac sprayed helium  on both VCR connections(5 seconds each) and flushed helium around the target for 6 seconds. No response on leak detector.

ELOG V2.9.2-2455