Entry  Thursday, August 29, 2013, 09:08, chad fisher, South Hot-Cell, Repair, TM3, , Heat Shield Circuit Leak 20130829_084751.jpg20130829_084754.jpg20130829_084949.jpg20130829_084957.jpg
    Reply  Thursday, August 29, 2013, 10:09, Bevan Moss, South Hot-Cell, Repair, TM3, , Heat Shield Circuit Leak 
       Reply  Thursday, August 29, 2013, 12:03, Grant Minor, South Hot-Cell, Repair, TM3, no target, Heat Shield Circuit Leak TM3_Rev_3_Heat_Shield_Water_Lines_leak_check_29Aug2013_1.jpgTM3_Rev_3_Heat_Shield_Water_Lines_leak_check_29Aug2013_2.jpgTM3_heatshield_snoop_test2_29Aug2013.pdf
Message ID: 437     Entry time: Thursday, August 29, 2013, 12:03     In reply to: 436
Author: Grant Minor 
Category: South Hot-Cell 
Type: Repair 
Module: TM3 
Target/Number: no target 
Subject: Heat Shield Circuit Leak 

Bevan Moss wrote:

chad fisher wrote:

The heat shield circuit was pressurized with air (15-20 psi) and snoop applied to the water block joint and brazes. Bubbles formed at the joint between the two water blocks indicating that the leak is a c seal problem. Pictures attached but also on docushare Collection-11285.

 Last night prior to this leak check the Heat Shield was pumped on and helium sprayed on the circuit. The pressure was 0.0 x 10^-4 Torr. The leak was traced to water block. response time was 2 seconds and went from 5.5 x 10^-8 to 1.6 x 10^-6 atm*cc/sec. There was also a response without spraying helium (drift from the nozzle). The results of this testing prompted the testing completed in Chads elog.

 Please find attached some schematics which help illustrate the setup for this heat-shield circuit leak check.

Attachment 1: TM3_Rev_3_Heat_Shield_Water_Lines_leak_check_29Aug2013_1.jpg  320 kB  | Hide | Hide all
TM3_Rev_3_Heat_Shield_Water_Lines_leak_check_29Aug2013_1.jpg
Attachment 2: TM3_Rev_3_Heat_Shield_Water_Lines_leak_check_29Aug2013_2.jpg  386 kB  | Show | Hide all
Attachment 3: TM3_heatshield_snoop_test2_29Aug2013.pdf  237 kB  Uploaded Thursday, August 29, 2013, 18:12  | Show | Hide all