Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 425     Entry time: Friday, August 23, 2013, 18:32
Author: Grant Minor 
Category: South Hot-Cell 
Type: Repair 
Module: TM3 
Target/Number:  
Subject: TM3 Rev 3 - steerer wire broken from connector on module side 

While continuing on the TM3 Rev 3 source tray installation, Chad noticed today that one of the steerer wires is broken and has come out of the thermocouple-style connecter block (see attached photos).

From drawing ITA2826 (Rev D02 attached) it is likely that this is for either the "upper" or "right side" steerer plate.

Attachment 1: TM3_Broken_Steerer_Wire_Module_Side_23Aug2013.JPG  2.381 MB  | Show | Hide all
Attachment 2: TM3_Broken_Steerer_Wire_Module_Side_23Aug2013-001.JPG  2.376 MB  | Show | Hide all
Attachment 3: TM3_Broken_Steerer_Wire_Module_Side_23Aug2013-002.JPG  2.236 MB  | Show | Hide all
Attachment 4: ITA2826D_RevD02_23Aug2013.pdf  163 kB  | Show | Hide all
Attachment 5: Thermocouple-style_connector_23Aug2013.JPG  1.741 MB  | Hide | Hide all
Thermocouple-style_connector_23Aug2013.JPG