ID Date Author Status Testdown Subject Text Attachments
  9   Friday, August 19, 2011, 10:04 John WongUnder Process1Evaporator#1 glovebox repairingThe evaporator#1 glovebox is leaking from
the gloves, around the ports, and the base
(possible more places).  It is evident
  
  10   Thursday, September 08, 2011, 15:41 Anders MjosFixed1Evaporator#1 glovebox repairing

    

       
            
  
  34   Wednesday, August 05, 2020, 19:50 Darwin Ortiz RosalesFixed1Hot Lab Glove Box RegenerationWednesday, August 05, 2020, 19:34
On Friday July 31 a regeneration
of the glovebox was started.
  
  46   Tuesday, April 18, 2023, 17:40 Keyur ChauhanFixed1Actinide Mass Balance CalibrationISAC-1 B1 Hot Lab
actinide mass balance calibration was carried
out on April 18, 2023, at 10:40 a.m. with
 Actinide_Mass_Balance_-_18_Apr_2023.pdf 
  1   Wednesday, March 30, 2011, 16:47 John Wong  All Fumehood pumps in hot and cold labs tripped off due to MCC-X powered downAll the fumehood pumps in the ISAC-I hot
and cold labs got tripped off when the MCC-X
was powered down (See ISAC WP#2011-03-30-5).
  
  2   Tuesday, April 12, 2011, 12:03 John Wong  Hot Lab Glove Box Regeneration Tue Apr 12 12:00:52 2011:  The hot
lab glove box regeneration was started yesterday
(April 11, 2011).  "Before regeneration,
  
  3   Tuesday, April 12, 2011, 12:07 John Wong  All Fumehood pumps in hot and cold labs tripped off due to MCC-X powered down

    

       
            
  
  4   Wednesday, April 13, 2011, 13:54 John Wong  Cloth booties now avaiable for hotlabWed Apr 13 13:53:46 2011

I've setup a box of cloth booties
for entering the hotlab.  They are
washable
  
  5   Friday, May 13, 2011, 11:59 John WongFixed Uranium Waste Container Removed from HotlabFri May 13 11:55:37 2011:  The contain
in the uranium waste container was removed
and transferred into a beaker and sealed. 
  
  6   Tuesday, June 21, 2011, 16:38 John WongFixed Planetary Ball Mill Re-Commisioning Tue Jun 21 16:30:48 2011: 
Re-Cap:  On June 13, 2011, the
milling jar gasket seal partially came out
  
  7   Friday, June 24, 2011, 18:00 John WongUnder Process TIS New Users Hi All,
As requested by Pierrer Bricault,
 I have added the following users to
 elog_demo.png 
  8   Tuesday, July 19, 2011, 16:26 John WongFixed Planetary Ball Mill moved to Hotlab Tuesday, July 19, 2011, 16:22:  The
planetary ball mill was in the coldlab, and
now it has moved to the hot lab for the purpose
 Screen_shot_2011-07-19_at_4.21.04_PM.png 
  11   Thursday, February 23, 2012, 13:38 Anders MjosFixed Water leak in chemistry / cold lab Please see attached file for notes
on the water leak from the cold lab fume
hood Tuesday Feb 21.
 Notes_on_water_leak_ISAC_I.docx 
  12   Tuesday, February 28, 2012, 12:01 John Wong  TIS/RH UsersTuesday, February 28, 2012, 11:31
Hi All,
Hope you all find the TIS/RH elog
  
  13   Friday, March 15, 2013, 13:55 Anders Mjos  Non active water off for a short time (10 - 15 min)ISAC operations called to check that equipment
in the labs were OK for the non active water
to be off for a short time. I gave the OK
  
  14   Wednesday, November 26, 2014, 14:01 Laura Lambert       
  15   Thursday, March 16, 2017, 09:32 Aaron SchmidtFixed D.H.W water pipe replacementFri 03/03/2017 17:00  - A water leak was noticed
on the D.H.W line. Hot water to the Cold
lab was shut down.

Wed 15/03/17 11:00
 DHW_pipe_replacement.docx 
  16   Wednesday, April 05, 2017, 08:22 Aaron SchmidtFixed D.H.W.R LeakWhen: 04/04/17 Between 09:00 & 11:30
Where:
ISAC 1 – Cold Lab
Who: Ron Murray & Aaron
Schmidt
A pin hole leak was found in the
  
  17   Thursday, July 13, 2017, 15:12 Laura LambertUnder Process D.H.W leak in SEM lab Thursday, July 13, 2017, 14:53
Same pipe that had a leak in the
cold lab ~1 month ago now has leak in SEM
 IMG_1713.JPGIMG_1715.JPGIMG_1716.JPGIMG_1719.JPG 
  18   Tuesday, August 08, 2017, 14:55 Laura Lambert  Glove box Alarm Tuesday, August 08, 2017, 14:28
Alarm for glove box went off this
afternoon.
  