OLIS Logbook General
  General, Page 9 of 26  Not logged in ELOG logo
ID Date Author Type Categorydown Subject Text Attachments
  124   Mon Aug 10 17:42:18 2009 Damien Gallop  MWS 25Mg emittance scan with original settingsFinally, here is the "original"
beam. Can you tell the difference (side-by-side
at bottom)? I can't.
 6x 
  125   Mon Aug 10 18:06:09 2009 Damien Gallop  MWS 25Mg reduce intensity with PESo... we have had this on-going problem
with intense Mg beam coating our optics.
Keerthi found a good recipe last week with
 grab.W23753.png 
  126   Mon Aug 10 18:29:32 2009 Damien Gallop  MWS source trip & restartWell, so it goes. As I was penning a note
for OPS, the source tripped. It easily reignited
with a little extra Ne. I left the flow slightly
 grab.q23803.png 
  127   Tue Aug 11 09:54:28 2009 Damien Gallop  MWS 25Mg operation overnight & MCIS cart installationAs noted earlier, the MWS beam dropped
out at some point after yesterday afternoon's
playtime, due to insufficient PE. Plasma
 grab.Z26532.pnggrab.Y26538.png 
  128   Fri Aug 14 13:53:34 2009 Damien Gallop  MWS 25Mg end of run dataMarco gave us the all-clear this morning
to shut down the MWS. We are preparing to
remove the MWS head from the Y-box and blank
 10x 
  129   Mon Aug 17 13:58:35 2009 Damien Gallop  Supernanogan Development begins today for one weekSupernanogan Development begins. It will
be a marathon. Main goals are high-charge
emittance scans and RF frequency scans. Tall
 Picture_43.pnggrab.a30699.png 
  130   Mon Aug 17 15:53:54 2009 Damien Gallop  MCIS mass scans & initial emittance scansHigh resolution zero to 25. Save file:
masscorr_mcis_090817-highres.txt
Ack! Elog server went down at ~17:00!!!
 11x 
  131   Tue Aug 18 11:16:16 2009 Damien Gallop  MCIS "PV" PLC trip overnightAnother in the on-going saga of MCIS:PV1
trips occurred again this morning. The operators
recovered most of the vacuum devices except
 grab.SXu928.pnggrab.eG1166.pnggrab.di1170.png 
  132   Tue Sep 8 15:14:45 2009 Damien Gallop  Back from vacationI'm back from vacation. Physically, anyway.
Keerthi did comprehensive emittance scans
during Supernanogan Development over the
 magstab_off-on.pngmagstab_on_10-sep-2009.pngmagstab_on_14-sep-2009.png 
  134   Tue Sep 15 09:54:22 2009 Damien Gallop  16O3+ run to DRAGON ended on schedule at 08:00The DRAGON run ended uneventfully. (That's
a good thing.) I ran a few emittance scans
on the beam as-is. It is clearly monoisotopic.
 8x 
  135   Tue Sep 15 10:32:39 2009 Damien Gallop  MCIS DevelopmentSo. We are preparing for a few days of
Supernanogan development. The present run
plan is to obtain good emittance scans for
 7x 
  136   Tue Sep 15 16:09:31 2009 Damien Gallop  MCIS Development 17O emittance scansWe noticed a double peak effect in the
16O3+ scan. I will set up the line for 17O3+
and see.
 13x 
  137   Tue Sep 15 16:56:03 2009 Damien Gallop  Test scans for publicationHere are pix of the same scan: original,
then greyscale, then cropped, using The GIMP.
Not bad.
 grab.E19994.pnggrab.U19879-greyscale.pnggrab.U19879-cropped.png 
  139   Tue Sep 15 20:02:46 2009 Keerthi  17O8+ on FC6 from MCIS0.4nA of 17O+8 is sitting on FC6. Development
will continue tomorrow.
 grab.I24583.png 
  141   Wed Sep 16 12:20:10 2009 Keerthi  17O+3 emittance with increased EL090916_1215ILTEMIT.txt   
EL increased, ~4.5uA, emittance increases,
50x100   17O+3
  
  143   Wed Sep 16 12:48:13 2009 Keerthi  17O+5 double peaks090916_1242ILTEMIT.txt  17O+5 has
two peaks.
090916_1355ILTEMIT.txt  Repeat
 grab.U24653.pnggrab.s24670.pnggrab.s24675.pnggrab.d24681.pnggrab.u24686.png 
  144   Wed Sep 16 18:14:29 2009 Damien Gallop  Test scans for publication 2090916_1206ILTEMIT.txt
Graphics with "color" in
the filename will look in print the same
 19x 
  145   Mon Sep 28 14:12:17 2009 Damien Gallop  33S5+ from MCIS on Friday 25-Sep-2009A sustained 33S5+ beam was generated in
the Supernanogan on Friday, September 25th.
Attached is a trar plot.
 33S_from_MCIS_25-Sep-2009.png 
  146   Mon Sep 28 14:16:47 2009 Damien Gallop  MCIS Cart down for TP1 ReplacementWe are taking the opportunity to replace
TP1 today. Edi Dalla Valle is on it. Also,
Diagnostics has a WP in the queue for looking
  
  147   Wed Sep 30 15:30:04 2009 Damien Gallop  33S6+ from MCIS for DRAGON setupBeam is stable enough to let Marco set
up something to DRAGON. We are a couple of
days early.
 grab.sA3956.pnggrab.ar3960.png 
ELOG V2.9.2-2455