OLIS Logbook General
  General, Page 8 of 26  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  119   Mon Aug 10 16:12:28 2009 Damien Gallop  MWS 25Mg operation over the weekendSummary: good.
Details: A trip occurred at some
point. I restarted the source over the weekende
 grab.m23211.pnggrab.F23215.png 
  128   Fri Aug 14 13:53:34 2009 Damien Gallop  MWS 25Mg end of run dataMarco gave us the all-clear this morning
to shut down the MWS. We are preparing to
remove the MWS head from the Y-box and blank
 10x 
  117   Fri Aug 7 10:16:38 2009 Damien Gallop  MWS 25Mg emittance scansWhile there is an SC cavity issue, I have
been repeating last evening's emittance scans.
Here is the best one. About 70nA of 25Mg
 6x 
  120   Mon Aug 10 16:36:33 2009 Damien Gallop  MWS 25Mg emittance scansA series of 25Mg emittance scans for Rick.
Starting scan with everything as-is,
i.e. slits closed.
 grab.d23286.pnggrab.w23291.pnggrab.U23295.pnggrab.U23312.pnggrab.q23316.png 
  123   Mon Aug 10 17:20:55 2009 Damien Gallop  MWS 25Mg emittance scan with zeroed vertical steerersHere is a variation I thought might be
appropriate.
Data file: 090810_1724ILTEMIT.txt
 grab.k23573.pnggrab.m23577.pnggrab.v23582.pnggrab.U23599.png 
  121   Mon Aug 10 16:43:59 2009 Damien Gallop  MWS 25Mg emittance scan with slits openBefore proceeding, I nudged in each of
the slits, watching for first clipping. With
the current emittance (nice), the beam cleared
 grab.G23396.pnggrab.g23400.pnggrab.r23404.png 
  124   Mon Aug 10 17:42:18 2009 Damien Gallop  MWS 25Mg emittance scan with original settingsFinally, here is the "original"
beam. Can you tell the difference (side-by-side
at bottom)? I can't.
 6x 
  122   Mon Aug 10 17:16:20 2009 Damien Gallop  MWS 25Mg emittance scan with downstream quads offHere is the emittance scan that Rick requested,
beam with Q4/5/6 off. Note that present numbers
for these quads do not match theoretical.
 grab.E23496.pnggrab.o23517.pnggrab.J23522.pnggrab.Q23526.png 
  118   Fri Aug 7 14:42:29 2009 Damien Gallop  MWS 25Mg beam reductionAround noon, Keerthi adjusted the PE down
to reduce the intensity of the Mg beam, as
we are running with attenuators in. He ended
 grab.jpa367.pnggrab.zFr371.pnggrab.PTd375.pnggrab.DYQ403.png 
  113   Mon Aug 3 08:39:31 2009 Damien Gallop  MWS 21Ne -> 25Mg switchoverConveniently scheduled for BC Day, we are
preparing to switch over the MWS to sputter
operation with MG source material. Operations
 grab.f18355.pnggrab.n18345.png 
  80   Thu Jul 16 14:11:43 2009 Damien Gallop  MCOL3 slits calibrationsI ran through a calibration exercise for
the IOS slits. Here is my data. I have moved
each set to the midpoint of the largest (5mm)
 grab.k15763.pnggrab.h15767.pnggrab.J15771.png 
  156   Sun Oct 11 13:16:39 2009 Keerthi  MCIS:TP3 was offMCIS TP3 foumd off by 1:00 pm.  Restarted
without a problem
Before TP3 is on MCIS:IG1 is 5.47e-8
  
  79   Thu Jul 16 14:06:56 2009 Damien Gallop  MCIS vacuum trip overnightThe MCIS vacuum system tripped last night
again. Fortunately the operators
noticed it and restarted stuff. Otherwise
 grab.X15685.png 
  68   Mon Jul 13 17:19:29 2009 Damien Gallop  MCIS vacuum trip at ~15:30An MCIS vacuum trip occurred somewhere
around 15:30. Sophia observed a drop-off
in beam. The cause looks like the PLC-related
 grab.Z26697.png 
  159   Sun Oct 11 17:11:31 2009 Keerthi  MCIS turbo pumps power levelsMCIS:TP1 = 12W
MCIS:TP2 = 11W
  
  133   Fri Sep 11 23:42:45 2009 KeerthiOtherGeneralMCIS turbo pumpMCIS TP1 is not running well. Needs investigation
as soon as S1219 is completed.
Later... TP1 failed completely, and
 mcis_multi-state.png 
  160   Tue Oct 13 14:14:17 2009 Damien Gallop  MCIS setup for 33S5+Keerthi has reinstalled the SO2 source
gas bottle onto MCIS. Presently it is closed
off to the source. We have restarted the
 Picture_2.pngPicture_3.pngPicture_4.pngPicture_5.png 
  498   Sat Nov 1 13:31:17 2014 Keerthi Jayamanna  MCIS readyness for 76SeSupernanogan is running with oven no heat,
without 76selenium. MCIS:IG1=3e-7Torr.
Tune saved as 141101_1318_76Se+11tune.snap
  
  178   Tue Nov 3 09:25:31 2009 Damien Gallop  MCIS online with 17O3+ on FC6 overnightWe completed 33S operation last night,
and roughed in a setup for 17O. We had 17O3+
on FC6 overnight; chart attached. It grew
 Picture_1.png 
  180   Thu Nov 5 09:45:03 2009 Damien Gallop  MCIS online with 17O3+ on FC6 overnightBeam was quiet overnight. Keerthi touched
up the tune this morning, and it is quieter
yet and a little more of it too.
 Picture_7.png 
ELOG V2.9.2-2455