  413   Mon Jul 18 10:02:42 2011 Damien Gallop  24Mg+6 from MWS for DRAGONKeerthi came in early this morning to set
up OLIS for 24Mg delivery. HEBT tuning is
in progress.
 Picture_2.pngPicture_3.pngPicture_4.png 
  412   Mon Jul 18 09:53:05 2011 Damien Gallop  4He from MCIS to HERACLES done Saturday and SundayKeerthi came in on Saturday morning and
set up the Supernanogan source for 4He delivery.
It looks like it went well. The original
  
  411   Fri Jul 15 10:30:11 2011 Damien Gallop  24/25Mg+1 from MWS for HERACLES on SEBT125Mg beam mostly sitting on FC6 now, as
HERACLES takes RIB. Source was opened
on Monday night to replace microwave window.
 Picture_6.pngPicture_7.pngPicture_8.pngPicture_9.pngPicture_10.png 
  410   Mon Jul 11 09:46:07 2011 Damien Gallop  24/25Mg+1 from MWS for HERACLES on SEBT1Well, the plasma electrode shorted again,
and Keerthi came in on Saturday to tear down
the MWS and clean it. Beam is steady as she
  
  409   Fri Jul 8 10:07:14 2011 Damien Gallop  24/25Mg+1 from MWS for HERACLES on SEBT1 
Beam on FC6 overnight and very stable.
It grew overnight and continues to grow,
 8x 
  408   Thu Jul 7 10:40:27 2011 Damien Gallop  24/25Mg+1 from MWS SetupSource conditioned nicely overnight at
55kV with a little RF power on. Source gases
checked, final cage inspection. Ready to
 6x 
  407   Wed Jul 6 13:20:15 2011 Damien Gallop  24/25Mg+1 from MWS SetupSource opened, and aluminum components
removed. Magnesium components from previous
run cleaned and installed. Pumpdown in progress.
 grab.jS3278.pnggrab.FQ5737.png 
  406   Wed Jul 6 09:56:45 2011 Damien Gallop  27Al+1 from MWS for DRAGON EOBDRAGON has been taking beam since approximately
noon on Monday, and finished a little while
ago. Feedback I have received is that beam
 13x 
  405   Sun Jul 3 09:56:47 2011 Damien Gallop  27Al+1 from MWS SetupA lot has happened since the last entry.
The source blinked out at some point. Cause
cited was a PE short. Actions were taken,
 grab.N30246.pnggrab.e30256.pnggrab.M30261.pnggrab.i30265.pnggrab.X30290.png 
  404   Thu Jun 30 10:02:08 2011 Damien Gallop  27Al+1 from MWS SetupSource pumped overnight to previous baseline
(red trace on attached Stripchart). IOPS
conditioned it up to 42kV without a hitch.
 Picture_2.pngPicture_3.pngPicture_4.pngPicture_5.png 
  403   Wed Jun 29 15:49:16 2011 Damien Gallop  27Al+1 from MWS SetupSwitchover from 58Ni+1/MCIS to 27Al+1/MWS
began just after noon. MWS cleaned and fitted
with aluminum liners. Pumping in progress.
 grab.Q27242.png 
  402   Wed Jun 29 09:45:50 2011 Damien Gallop  58Ni from MCIS to TITANLast hours and minutes. Going well. Documentation
appended. Users have requested beam until
noon.
 8x 
  401   Tue Jun 28 09:32:09 2011 Damien Gallop  58Ni from MCIS to TITANBeam mostly idle overnight. Things are
resuming now.
 Picture_4.png 
  400   Mon Jun 27 10:20:41 2011 Damien Gallop  58Ni from MCIS to TITANFrom MCIS. It looks like things went fairly
well over the weekend for them. An interlock
glitch on MCIS:IV1 this morning, source pressure
 Picture_1.pngPicture_2.png 
  399   Fri Jun 24 15:11:20 2011 Damien Gallop  58Ni from MCIS to FC6 SetupOLIS was switched from 22Ne2+ (MWS) to
58Ni+1 (MCIS). Works like magic. 100epA presently.
  
  398   Fri Jun 10 11:35:24 2011 Damien Gallop  22Ne2+ for TUDA-II Pilot BeamMWS online. Beam sitting on FC6.
Mel returned two flow controllers
today, borrowed in March
  
  397   Thu Jun 9 16:51:09 2011 Damien Gallop  22Ne2+ for TUDA-II Pilot BeamMWS online. Note: A/q display is white.
Possible culprit: IOSIOC. ICR will reboot
it at first convenient opportunity.
 Picture_1.pngPicture_4.pngPicture_3.pngPicture_2.pngPicture_5.png 
  396   Mon May 30 14:44:01 2011 Damien Gallop  22Ne2+ for ICR TrainingMWS online. Separator magstab program offline.
Check: Kepco is switched off and one lead
is physically cut and taped over. That's
 IMG_0093.jpg 
  395   Mon May 2 10:50:28 2011 Damien Gallop  Alkalis for DRAGON EOBDRAGON has been taking various species
of Na and Rb using the MWS. Run ended this
morning. Emittance scan of 23Na attached.
 7x 
  394   Fri Apr 1 17:02:09 2011 Damien Gallop  12C2+ for StartupSupernanogan is online with a bit of 12C2+
beam on FC6. Mag stability program is running.
Source development to follow.
  
ELOG V2.9.2-2455