| ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
|
413
|
Mon Jul 18 10:02:42 2011 |
Damien Gallop | | | 24Mg+6 from MWS for DRAGON | Keerthi came in early this morning to set
up OLIS for 24Mg delivery. HEBT tuning is
in progress. |
  |
|
412
|
Mon Jul 18 09:53:05 2011 |
Damien Gallop | | | 4He from MCIS to HERACLES done Saturday and Sunday | Keerthi came in on Saturday morning and
set up the Supernanogan source for 4He delivery.
It looks like it went well. The original |
|
|
411
|
Fri Jul 15 10:30:11 2011 |
Damien Gallop | | | 24/25Mg+1 from MWS for HERACLES on SEBT1 | 25Mg beam mostly sitting on FC6 now, as
HERACLES takes RIB. Source was opened
on Monday night to replace microwave window. |
    |
|
410
|
Mon Jul 11 09:46:07 2011 |
Damien Gallop | | | 24/25Mg+1 from MWS for HERACLES on SEBT1 | Well, the plasma electrode shorted again,
and Keerthi came in on Saturday to tear down
the MWS and clean it. Beam is steady as she |
|
|
409
|
Fri Jul 8 10:07:14 2011 |
Damien Gallop | | | 24/25Mg+1 from MWS for HERACLES on SEBT1 |
Beam on FC6 overnight and very stable.
It grew overnight and continues to grow, |
8x |
|
408
|
Thu Jul 7 10:40:27 2011 |
Damien Gallop | | | 24/25Mg+1 from MWS Setup | Source conditioned nicely overnight at
55kV with a little RF power on. Source gases
checked, final cage inspection. Ready to |
6x |
|
407
|
Wed Jul 6 13:20:15 2011 |
Damien Gallop | | | 24/25Mg+1 from MWS Setup | Source opened, and aluminum components
removed. Magnesium components from previous
run cleaned and installed. Pumpdown in progress. |
 |
|
406
|
Wed Jul 6 09:56:45 2011 |
Damien Gallop | | | 27Al+1 from MWS for DRAGON EOB | DRAGON has been taking beam since approximately
noon on Monday, and finished a little while
ago. Feedback I have received is that beam |
13x |
|
405
|
Sun Jul 3 09:56:47 2011 |
Damien Gallop | | | 27Al+1 from MWS Setup | A lot has happened since the last entry.
The source blinked out at some point. Cause
cited was a PE short. Actions were taken, |
    |
|
404
|
Thu Jun 30 10:02:08 2011 |
Damien Gallop | | | 27Al+1 from MWS Setup | Source pumped overnight to previous baseline
(red trace on attached Stripchart). IOPS
conditioned it up to 42kV without a hitch. |
   |
|
403
|
Wed Jun 29 15:49:16 2011 |
Damien Gallop | | | 27Al+1 from MWS Setup | Switchover from 58Ni+1/MCIS to 27Al+1/MWS
began just after noon. MWS cleaned and fitted
with aluminum liners. Pumping in progress. |
|
|
402
|
Wed Jun 29 09:45:50 2011 |
Damien Gallop | | | 58Ni from MCIS to TITAN | Last hours and minutes. Going well. Documentation
appended. Users have requested beam until
noon. |
8x |
|
401
|
Tue Jun 28 09:32:09 2011 |
Damien Gallop | | | 58Ni from MCIS to TITAN | Beam mostly idle overnight. Things are
resuming now. |
|
|
400
|
Mon Jun 27 10:20:41 2011 |
Damien Gallop | | | 58Ni from MCIS to TITAN | From MCIS. It looks like things went fairly
well over the weekend for them. An interlock
glitch on MCIS:IV1 this morning, source pressure |
 |
|
399
|
Fri Jun 24 15:11:20 2011 |
Damien Gallop | | | 58Ni from MCIS to FC6 Setup | OLIS was switched from 22Ne2+ (MWS) to
58Ni+1 (MCIS). Works like magic. 100epA presently. |
|
|
398
|
Fri Jun 10 11:35:24 2011 |
Damien Gallop | | | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Beam sitting on FC6.
Mel returned two flow controllers
today, borrowed in March |
|
|
397
|
Thu Jun 9 16:51:09 2011 |
Damien Gallop | | | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Note: A/q display is white.
Possible culprit: IOSIOC. ICR will reboot
it at first convenient opportunity. |
    |
|
396
|
Mon May 30 14:44:01 2011 |
Damien Gallop | | | 22Ne2+ for ICR Training | MWS online. Separator magstab program offline.
Check: Kepco is switched off and one lead
is physically cut and taped over. That's |
|
|
395
|
Mon May 2 10:50:28 2011 |
Damien Gallop | | | Alkalis for DRAGON EOB | DRAGON has been taking various species
of Na and Rb using the MWS. Run ended this
morning. Emittance scan of 23Na attached. |
7x |
|
394
|
Fri Apr 1 17:02:09 2011 |
Damien Gallop | | | 12C2+ for Startup | Supernanogan is online with a bit of 12C2+
beam on FC6. Mag stability program is running.
Source development to follow. |
|