|   | 
ID | 
Date | 
Author | 
Type | 
Category | 
Subject | 
Text | 
  | 
| 
 | 
  413  
 | 
Mon Jul 18 10:02:42 2011 | 
Damien Gallop |   |   | 24Mg+6 from MWS for DRAGON | Keerthi came in early this morning to set 
up OLIS for 24Mg delivery. HEBT tuning is 
in progress. | 
      | 
| 
 | 
  412  
 | 
Mon Jul 18 09:53:05 2011 | 
Damien Gallop |   |   | 4He from MCIS to HERACLES done Saturday and Sunday | Keerthi came in on Saturday morning and 
set up the Supernanogan source for 4He delivery. 
It looks like it went well. The original | 
   | 
| 
 | 
  411  
 | 
Fri Jul 15 10:30:11 2011 | 
Damien Gallop |   |   | 24/25Mg+1 from MWS for HERACLES on SEBT1 | 25Mg beam mostly sitting on FC6 now, as 
HERACLES takes RIB. Source was opened 
on Monday night to replace microwave window. | 
        | 
| 
 | 
  410  
 | 
Mon Jul 11 09:46:07 2011 | 
Damien Gallop |   |   | 24/25Mg+1 from MWS for HERACLES on SEBT1 | Well, the plasma electrode shorted again, 
and Keerthi came in on Saturday to tear down 
the MWS and clean it. Beam is steady as she | 
   | 
| 
 | 
  409  
 | 
Fri Jul  8 10:07:14 2011 | 
Damien Gallop |   |   | 24/25Mg+1 from MWS for HERACLES on SEBT1 |  
 
Beam on FC6 overnight and very stable. 
It grew overnight and continues to grow, | 
 8x   | 
| 
 | 
  408  
 | 
Thu Jul  7 10:40:27 2011 | 
Damien Gallop |   |   | 24/25Mg+1 from MWS Setup | Source conditioned nicely overnight at 
55kV with a little RF power on. Source gases 
checked, final cage inspection. Ready to | 
 6x   | 
| 
 | 
  407  
 | 
Wed Jul  6 13:20:15 2011 | 
Damien Gallop |   |   | 24/25Mg+1 from MWS Setup | Source opened, and aluminum components 
removed. Magnesium components from previous 
run cleaned and installed. Pumpdown in progress. | 
     | 
| 
 | 
  406  
 | 
Wed Jul  6 09:56:45 2011 | 
Damien Gallop |   |   | 27Al+1 from MWS for DRAGON EOB | DRAGON has been taking beam since approximately 
noon on Monday, and finished a little while 
ago. Feedback I have received is that beam | 
 13x   | 
| 
 | 
  405  
 | 
Sun Jul  3 09:56:47 2011 | 
Damien Gallop |   |   | 27Al+1 from MWS Setup | A lot has happened since the last entry. 
The source blinked out at some point. Cause 
cited was a PE short. Actions were taken, | 
        | 
| 
 | 
  404  
 | 
Thu Jun 30 10:02:08 2011 | 
Damien Gallop |   |   | 27Al+1 from MWS Setup | Source pumped overnight to previous baseline 
(red trace on attached Stripchart). IOPS 
conditioned it up to 42kV without a hitch. | 
       | 
| 
 | 
  403  
 | 
Wed Jun 29 15:49:16 2011 | 
Damien Gallop |   |   | 27Al+1 from MWS Setup | Switchover from 58Ni+1/MCIS to 27Al+1/MWS 
began just after noon. MWS cleaned and fitted 
with aluminum liners. Pumping in progress. | 
    | 
| 
 | 
  402  
 | 
Wed Jun 29 09:45:50 2011 | 
Damien Gallop |   |   | 58Ni from MCIS to TITAN | Last hours and minutes. Going well. Documentation 
appended. Users have requested beam until 
noon. | 
 8x   | 
| 
 | 
  401  
 | 
Tue Jun 28 09:32:09 2011 | 
Damien Gallop |   |   | 58Ni from MCIS to TITAN | Beam mostly idle overnight. Things are 
resuming now. | 
    | 
| 
 | 
  400  
 | 
Mon Jun 27 10:20:41 2011 | 
Damien Gallop |   |   | 58Ni from MCIS to TITAN | From MCIS. It looks like things went fairly 
well over the weekend for them. An interlock 
glitch on MCIS:IV1 this morning, source pressure | 
     | 
| 
 | 
  399  
 | 
Fri Jun 24 15:11:20 2011 | 
Damien Gallop |   |   | 58Ni from MCIS to FC6 Setup | OLIS was switched from 22Ne2+ (MWS) to 
58Ni+1 (MCIS). Works like magic. 100epA presently. | 
   | 
| 
 | 
  398  
 | 
Fri Jun 10 11:35:24 2011 | 
Damien Gallop |   |   | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Beam sitting on FC6.
 
Mel returned two flow controllers 
today, borrowed in March | 
   | 
| 
 | 
  397  
 | 
Thu Jun  9 16:51:09 2011 | 
Damien Gallop |   |   | 22Ne2+ for TUDA-II Pilot Beam | MWS online. Note: A/q display is white. 
Possible culprit: IOSIOC. ICR will reboot 
it at first convenient opportunity. | 
        | 
| 
 | 
  396  
 | 
Mon May 30 14:44:01 2011 | 
Damien Gallop |   |   | 22Ne2+ for ICR Training | MWS online. Separator magstab program offline. 
Check: Kepco is switched off and one lead 
is physically cut and taped over. That's | 
    | 
| 
 | 
  395  
 | 
Mon May  2 10:50:28 2011 | 
Damien Gallop |   |   | Alkalis for DRAGON EOB | DRAGON has been taking various species 
of Na and Rb using the MWS. Run ended this 
morning. Emittance scan of 23Na attached. | 
 7x   | 
| 
 | 
  394  
 | 
Fri Apr  1 17:02:09 2011 | 
Damien Gallop |   |   | 12C2+ for Startup | Supernanogan is online with a bit of 12C2+ 
beam on FC6. Mag stability program is running. 
Source development to follow. | 
   |