OLIS Logbook General
  General, Page 2 of 26  Not logged in ELOG logo
ID Date Author Type Categoryup Subject
  84   Thu Jul 16 14:46:52 2009 Damien Gallop  16O7+ survey

A/q = 2.2857 Field = 708.0G FC6 = 70epA (noisy)

No emittance scan possible.

  85   Thu Jul 16 14:50:38 2009 Damien Gallop  18O7+ survey

A/q = 2.5714 Field = 751.1G FC6 = 40epA

No emittance scan possible.

  86   Thu Jul 16 15:11:16 2009 Damien Gallop  16O6+ survey

A/q = 2.6667 Field = 764.7G FC6 = 3.0nA

Attachment 1: grab.e16164.png
grab.e16164.png
Attachment 2: grab.z16169.png
grab.z16169.png
Attachment 3: grab.a16173.png
grab.a16173.png
  87   Thu Jul 16 15:22:51 2009 Damien Gallop  18O6+ survey

A/q = 3 Field = 811.2G FC6 = 1.6nA

Not quite enough beam for an emittance scan.

Attachment 1: grab.Z16300.png
grab.Z16300.png
  88   Thu Jul 16 15:38:58 2009 Damien Gallop  16O5+ survey

A/q = 3.2 Field = 837.7G FC6 = 14.5enA

Attachment 1: grab.a16526.png
grab.a16526.png
Attachment 2: grab.l16532.png
grab.l16532.png
Attachment 3: grab.N16536.png
grab.N16536.png
  89   Thu Jul 16 15:41:35 2009 Damien Gallop  18O5+ survey

A/q = 3.6 Field = 888.6G FC6 = 6.2enA

Attachment 1: grab.d16597.png
grab.d16597.png
Attachment 2: grab.v16602.png
grab.v16602.png
Attachment 3: grab.z16609.png
grab.z16609.png
  90   Thu Jul 16 15:49:46 2009 Damien Gallop  16O4+ survey

A/q = 4 Field = 936.7 FC6 = 54.0enA

Attachment 1: grab.W16723.png
grab.W16723.png
Attachment 2: grab.F16727.png
grab.F16727.png
Attachment 3: grab.l16731.png
grab.l16731.png
  91   Thu Jul 16 15:58:53 2009 Damien Gallop  18O4+ survey

A/q = 4.5 Field = 993.5G FC6 = 20enA

Attachment 1: grab.Q16857.png
grab.Q16857.png
Attachment 2: grab.l16862.png
grab.l16862.png
Attachment 3: grab.r16890.png
grab.r16890.png
  92   Thu Jul 16 16:15:39 2009 Damien Gallop  16O3+ survey

A/q = 5.3333 Field = 1081.6G FC6 = 110nA

Attachment 1: grab.F17014.png
grab.F17014.png
Attachment 2: grab.D17019.png
grab.D17019.png
Attachment 3: grab.E17026.png
grab.E17026.png
  93   Thu Jul 16 16:33:28 2009 Damien Gallop  18O3+ survey

A/q = 6 Field = 1147.2 FC6 = 39.3enA

Attachment 1: grab.k17100.png
grab.k17100.png
Attachment 2: grab.e17104.png
grab.e17104.png
Attachment 3: grab.E17109.png
grab.E17109.png
  94   Thu Jul 16 16:40:11 2009 Damien Gallop  16O2+ survey

A/q = 8 Field = 1324.8G FC6 = 172enA

Attachment 1: grab.u17187.png
grab.u17187.png
Attachment 2: grab.U17191.png
grab.U17191.png
Attachment 3: grab.s17196.png
grab.s17196.png
  95   Thu Jul 16 16:50:41 2009 Damien Gallop  18O2+ survey

A/q = 9 Field = 1405.0G FC6 = 55enA

Attachment 1: grab.N17330.png
grab.N17330.png
Attachment 2: grab.Y17335.png
grab.Y17335.png
Attachment 3: grab.w17339.png
grab.w17339.png
  96   Thu Jul 16 17:05:29 2009 Damien Gallop  16O1+ survey

A/q = 16 Field = 1873.4G FC6 = 204enA

Attachment 1: grab.o17385.png
grab.o17385.png
Attachment 2: grab.G17390.png
grab.G17390.png
Attachment 3: grab.B17394.png
grab.B17394.png
  97   Thu Jul 16 17:09:52 2009 Damien Gallop  18O1+ survey

A/q = 18 Field = 1987.1 FC6 = 161nA

Attachment 1: grab.b17471.png
grab.b17471.png
Attachment 2: grab.r17475.png
grab.r17475.png
Attachment 3: grab.R17480.png
grab.R17480.png
  98   Thu Jul 16 17:15:50 2009 Damien Gallop  16/18On+ survey summary

Here is a summary of emittances gleaned from the aforementioned elog entries.

A/q

 Isotope Intensity  Composite  E39% E63% E86% E90% Datafile
2.0 16O8+ 150epA Yes          
2.0 16O8+ 10enA Yes          
2.25 18O8+ 0            
2.25 18O8+ 110enA            
2.2857 16O7+ 70epA            
2.2857 16O7+ 100epA            
2.5714 18O7+ 40epA            
2.5714 18O7+ 50epA            
2.6667 16O6+ 3.0enA   1.61 2.89 4.39 4.6 090716_1505ILTEMIT.txt
2.6667 16O6+ 3.0enA   1.74 3.08 4.64 4.9 090717_1056ILTEMIT.txt
3.0 18O6+ 1.6enA Yes         090716_1519ILTEMIT.txt
3.0 18O6+ 2.2enA Yes 1.53 2.78 4.19 4.39 090717_1014ILTEMIT.txt
3.0 18O6+ 2.9enA Yes 0.422 0.774 1.15 1.2 090715_1430ILTEMIT.txt
3.2 16O5+ 14.5enA   3.58 7.02 12.0 13.0 090716_1535ILTEMIT.txt
3.6 18O5+ 6.2enA   2.77 5.2 8.39 8.98 090716_1543ILTEMIT.txt
3.6 18O5+ 10enA   2.59 4.74 7.49 7.98 090715_1615ILTEMIT.txt
3.6 18O5+ 10enA   2.96 5.53 8.77 9.37 090715_1446ILTEMIT.txt
4.0 16O4+ 54enA  Yes 3.87 7.54 13.2 14.4 090716_1555ILTEMIT.txt
4.5 18O4+ 20enA   3.59 7.04 12.4 13.5 090716_1609ILTEMIT.txt
4.5 18O4+ 24enA   4.05 8.02 14.6 16.0 090716_1411ILTEMIT.txt
5.3333 16O3+ 110enA   3.99 7.83 14 15.4 090716_1626ILTEMIT.txt
6.0 18O3+ 39.3enA  Yes 3.81 7.42 13.1 14.4 090716_1636ILTEMIT.txt
8.0 16O2+ 172enA   4.7 8.74 15.1 16.6 090716_1645ILTEMIT.txt
9.0 18O2+ 55enA   5.1 9.54 17.0 18.7 090716_1700ILTEMIT.tx
16.0 16O1+ 204nA   9.3 16.7 27.2 29.4 090716_1707ILTEMIT.txt
18.0 18O1+ 161nA  Yes 8.05 14.5 23.5 25.4 090716_1715ILTEMIT.txt

 18O4+ restored onto FC6 ~20enA, which seems slightly low.

  99   Fri Jul 17 09:33:09 2009 Damien Gallop  Supernanogan epilogue

There are the last couple of hours of Supernanogan Development for this set. Our run plan included 17On+ studies. Time will not permit it this time around. Also, the emittance numbers of 16O and 18O are not distinctive enough as they stand to warrant studies of the in-between mass. Keerthi will run the emittance data files through his software during post-analysis, and we'll develop our next run plan based on his conclusions.

This morning I will redo a couple of emittance scans that were not optimal yesterday. We'll start with an 18O4+ emittance check, then 18O8+, where, though I don't expect an emittance scan, I do expect to see beam. A vacuum trip on Wednesday evening probably compromised source vacuum and therefore the ability to generate the higher charge states. Here we go.

18O4+ emittance checks well.

Attachment 1: grab.a24906.png
grab.a24906.png
Attachment 2: grab.Q24916.png
grab.Q24916.png
  100   Fri Jul 17 09:47:16 2009 Damien Gallop  18O8+ recheck

Go fishing in the range 2.24-2.26, but no fish in this pond this time. However, there is a relatively strong beam at 2.3.

A/q = 2.3 Field = 711.2 FC6 = 110enA

No emittance scan possible.

I did a check at A/q = 2, and found a strong peak at 2.04 field 668.8 18enA, suggesting that the A/q panel calibration is slightly off for the lower masses, and in the right direction for the above to indeed be 18O8+. Good stuff.

Next stop: 18O6+.

  101   Fri Jul 17 10:03:07 2009 Damien Gallop  18O6+ recheck

A/q = 3 Field = 813.9G FC6 = 2.2enA

I tweaked the adjustment of the displayed A/q calibration to fit this one.

Attachment 1: grab.a25266.png
grab.a25266.png
Attachment 2: grab.J25270.png
grab.J25270.png
Attachment 3: grab.C25275.png
grab.C25275.png
  102   Fri Jul 17 10:28:09 2009 Damien Gallop  18O7+ recheck

A/q = 2.571 Field = 753.5 FC6 = 50epA

  103   Fri Jul 17 10:30:27 2009 Damien Gallop  16O7+ recheck

A/q = 2.2857 Field = 710.5G FC6 = 100pA

ELOG V2.9.2-2455