33
|
Wed Jun 24 10:27:23 2009 |
Damien Gallop | Routine | General | 16O2+ tune ready for Sophia and Marco | See ISAC elog entry today.
Keerthi developed a dual-mode tune last night,
so that we can run the MWS at will if so |
|
|
32
|
Tue Jun 23 18:04:30 2009 |
Damien Gallop | Routine | General | MCIS HV conditioning to 20KV | Supernanogan bias for this run is 16.32KV.
After we were finished with source tuning,
etc., we conditioned up to 20KV. Then beam |
|
|
31
|
Tue Jun 23 16:48:00 2009 |
Damien Gallop | Routine | General | 16O2+ on FC6 after source tuning | After a first round of source and line
tuning for good current with minimum RF power,
we have about 8nA of 16O2+ on FC6. Here is |
|
|
30
|
Tue Jun 23 15:02:38 2009 |
Damien Gallop | Routine | General | 16O2+ on FC6 | We now have about 80nA of 16O2+, using
the same source parameters as before. Keep
a watch for a while, then tune the source |
|
|
29
|
Tue Jun 23 10:33:43 2009 |
Damien Gallop | Routine | General | Effects of RF on charge state | Today is the last day of this set of Supernanogan
Development. The source ran at 16KV overnight,
in anticipation of 16O2+ delivery later today. |
|
|
28
|
Mon Jun 22 20:28:37 2009 |
Damien Gallop | Routine | General | Preparations for 16O2+ delivery | In anticipation of 16O2+ delivery mid-week,
we checked 16O2+ production from the Supernanogan
source. No problem. We did have to use the |
6x |
|
27
|
Mon Jun 22 16:00:04 2009 |
Damien Gallop | Routine | General | Emittance thoughts and other matters | An emittance scan of the 16O7+ beam follows.
Also, a stripchart of the same beam on FC6
overnight. Keerthi did some studies over |
7x |
|
26
|
Fri Jun 19 20:15:19 2009 |
Damien Gallop | Routine | General | Summary of 16On+ emittance scans | Here is a list of 16On+ emittance scans
for today. Although IOSIOC got rebooted,
restored tune was identical and trouble-free, |
|
|
25
|
Fri Jun 19 11:59:49 2009 |
Damien Gallop | Routine | General | 16On+ emittance scans continue | Keerthi developed a nice 16O7+ beam to
FC6 last night. Beam current is about 3nA
presently. Here is the first emittance scan |
18x |
|
24
|
Thu Jun 18 09:38:52 2009 |
Damien Gallop | Routine | General | Check Supernanogan beam after IOC reboot yesterday | As mentioned before, IOSIOC was rebooted
yesterday afternoon to unfreeze the emittance
rig panel. It cost us our tune, which unfortunately |
15x |
|
23
|
Wed Jun 17 17:01:07 2009 |
Damien Gallop | Routine | General | 16On+ emittance scans | A series of 16On+ emittance scans. Benchmark
scan of 16O5+ matched well with same scan
done this morning. Subsequent scans beginning |
|
|
22
|
Wed Jun 17 10:14:57 2009 |
Damien Gallop | Routine | General | 16O5+ on FC6 overnight | The 16O5+ beam stayed up OK overnight.
ICR took some emittance
scans this morning. They look interesting. |
6x |
|
21
|
Tue Jun 16 16:47:02 2009 |
Damien Gallop | Routine | General | Mass scan around 16O5+ | Keerthi suggested using 16O5+ for optimizing
the source. I did a tight mass scan in that
area, and 16O5+ is clearly visible. I will |
|
|
20
|
Tue Jun 16 12:10:17 2009 |
Damien Gallop | Routine | General | 84Kr charge states begun |
|
|
|
19
|
Mon Jun 15 17:49:23 2009 |
Damien Gallop | Routine | General | 84Kr charge states begun | We began looking at 84Kr this weekend.
Keerthi had 84Kr19+ on FC6 this morning,
which I was able to tweak up from ~300epA |
|
|
18
|
Fri Jun 12 14:24:49 2009 |
Damien Gallop | Routine | General | 17O3+ beam at optimized RF | A comment about RF power came up at the
presentation this morning. Intense X-rays
can be produced not only at the peak efficiency |
|
|
17
|
Fri Jun 12 14:12:04 2009 |
Damien Gallop | Routine | General | OLIS & Supernanogan Facilities presentation | Presentation this morning in Auditorium.
Players:
Keerthi: science |
|
|
16
|
Thu Jun 11 12:10:22 2009 |
Damien Gallop | Routine | General | Supernanogan status | Pumping went well overnight. TP3 turned
on around noon. Issues with Kepco communications. |
|
|
15
|
Wed Jun 10 18:48:53 2009 |
Damien Gallop | Routine | General | Krypton source gas fitted | Krypton source gas teed directly into ion
source. A Nupro valve and tee also added
for 17O line. At present, the 17O gas bottle |
|
|
14
|
Wed Jun 10 17:49:40 2009 |
Damien Gallop | Routine | General | Beam to RFQ | We handed over the beam to Sophia for testing
Rick's new tune. Although there are RF issues
at the RFQ presently, her feedback to the |
|