ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
90
|
Thu Jul 16 15:49:46 2009 |
Damien Gallop | | | 16O4+ survey | A/q = 4 Field = 936.7 FC6 = 54.0enA |
  |
92
|
Thu Jul 16 16:15:39 2009 |
Damien Gallop | | | 16O3+ survey | A/q = 5.3333 Field = 1081.6G FC6 = 110nA |
  |
134
|
Tue Sep 15 09:54:22 2009 |
Damien Gallop | | | 16O3+ run to DRAGON ended on schedule at 08:00 | The DRAGON run ended uneventfully. (That's
a good thing.) I ran a few emittance scans
on the beam as-is. It is clearly monoisotopic. |
8x |
326
|
Thu Aug 5 17:47:04 2010 |
Damien Gallop | | | 16O3+ for TIGRESS EOB Tuesday a.m. | Delivery of 16O3+ for TIGRESS "buddy
beam" purposes ended early Tuesday morning, |
|
324
|
Fri Jul 30 09:09:35 2010 |
Damien Gallop | | | 16O3+ for TIGRESS | Supernanogan is online. Setup done last
night. There is room for tweaking, but stable
3enA on FC6 of 16O3+ presently. We'll see |
   |
325
|
Tue Aug 3 09:31:30 2010 |
Damien Gallop | | | 16O3+ for TIGRESS | Beam idle for most of the weekend. Some
ion source ups and downs, in part due to
a WFB setting on the edge. Tuning began last |
|
334
|
Fri Sep 10 10:38:13 2010 |
Damien Gallop | | | 16O3+ for DRAGON | |
|
323
|
Thu Jul 29 18:12:38 2010 |
Damien Gallop | | | 16O3+ Setup | So... the long-awaited word to switch OLIS
beams and sources finally came through...
at 17:45. |
6x |
33
|
Wed Jun 24 10:27:23 2009 |
Damien Gallop | Routine | General | 16O2+ tune ready for Sophia and Marco | See ISAC elog entry today.
Keerthi developed a dual-mode tune last night,
so that we can run the MWS at will if so |
   |
94
|
Thu Jul 16 16:40:11 2009 |
Damien Gallop | | | 16O2+ survey | A/q = 8 Field = 1324.8G FC6 = 172enA |
  |
34
|
Mon Jun 29 10:35:35 2009 |
Damien Gallop | Routine | General | 16O2+ pilot beam to TACTIC in progress | We handed over a 16O2+ beam on Wednesday
morning to Sophia for TACTIC setup. On our
side, everything went well. TACTIC switched |
  |
31
|
Tue Jun 23 16:48:00 2009 |
Damien Gallop | Routine | General | 16O2+ on FC6 after source tuning | After a first round of source and line
tuning for good current with minimum RF power,
we have about 8nA of 16O2+ on FC6. Here is |
   |
30
|
Tue Jun 23 15:02:38 2009 |
Damien Gallop | Routine | General | 16O2+ on FC6 | We now have about 80nA of 16O2+, using
the same source parameters as before. Keep
a watch for a while, then tune the source |
    |
38
|
Tue Jun 30 17:16:25 2009 |
Damien Gallop | Routine | General | 16O2+ emittance scans with slits open | First, with upstream slits opened, then
with both open. Original slit setting was
1mm. Finally, restore slits to 1mm and see |
6x |
37
|
Tue Jun 30 10:56:26 2009 |
Damien Gallop | Routine | General | 16O2+ emittance scans | The first emittance scan sort of got interrupted;
it auto-restarted just before the previous
scan had finished. I thought the resulting |
6x |
96
|
Thu Jul 16 17:05:29 2009 |
Damien Gallop | | | 16O1+ survey | A/q = 16 Field = 1873.4G FC6 = 204enA |
  |
308
|
Wed Jul 7 15:21:36 2010 |
Damien Gallop | | | 16O1+ for SCC Commissioning | A 16O1+ beam from the MWS is being used
for SCC development and commissioning by
agreement. Some sideshows getting there. |
|
253
|
Mon Apr 26 10:58:46 2010 |
Damien Gallop | | | 16O1+ at 32.64keV to SEBT2 | Our first experiment of the year started
right around midnight last night, after extensive
tuning. As I understand it, S1151 |
|
254
|
Tue Apr 27 09:04:13 2010 |
Damien Gallop | | | 16O1+ at 32.64keV to SEBT2 | Nominal beam operation to SEBT2 overnight.
A chart of beam over the last few days is
attached. There is a step change in the separator |
  |
255
|
Wed Apr 28 10:08:05 2010 |
Damien Gallop | | | 16O1+ at 32.64keV to SEBT2 | Beam delivery continued nicely through
the night.
Yesterday Controls repaired and reinstalled |
|