OLIS Logbook
General
General, Page 21 of 26
Not logged in
List
|
Find
|
Select
|
Import
|
Login
|
Help
Full
| Summary |
Threaded
513 Entries
Goto page
Previous
1
,
2
,
3
...
20
, 21,
22
...
24
,
25
,
26
Next
ID
Date
Author
Type
Category
Subject
Text
370
Mon Nov 29 08:55:35 2010
Damien Gallop
12C2+ for Commissioning
Supernanogan is online. MCIS:TP3 is off.
It should be on. It is required for best
production of higher charge states.
371
Tue Nov 30 08:47:47 2010
Damien Gallop
12C2+ for Commissioning
Commissioning and development
continue.
372
Wed Dec 1 08:51:54 2010
Damien Gallop
12C2+ for Commissioning
Continuing from Supernanogan. Source touch-up
last evening.
373
Thu Dec 2 10:02:46 2010
Damien Gallop
12C2+ for Commissioning
Accelerator development continues. Save:
101201_2157.snaiosvault. Today's agenda:
emittance scans. Attached: overnight beam
14x
374
Fri Dec 3 09:37:14 2010
Damien Gallop
12C2+ for Commissioning
Last moments of beam development for SEBT
commissioning. Attached is an FC6 plot and
the present optics and 1mm slits. Decision
15x
375
Mon Dec 6 09:08:52 2010
Damien Gallop
80Kr14+/40Ar7+ for SEBT Development
The previous 12C2+ development run from
the Supernanogan ended Friday morning. Starting
Friday afternoon, the Supernanogan was prepared
376
Tue Dec 7 08:57:26 2010
Damien Gallop
80Kr14+/40Ar7+ for SEBT Development
Development should continue today. Looks
like Supernanogan went through a plasma mode
change overnight and settled into a new mode.
377
Tue Dec 14 09:15:58 2010
Damien Gallop
MCIS Development
Beam development started yesterday. Looks
like the HERACLES run, which started Thursday,
ended yesterday morning.
378
Wed Dec 15 09:18:41 2010
Damien Gallop
MCIS Development
Source development in preparation for Au
beam in progress.
379
Fri Dec 17 09:18:57 2010
Damien Gallop
MCIS Development
Development continues in the search for
gold. A=197 Present A/q=5.94, which suggests
197Au+33. It could also be a tail of 12C+2.
380
Mon Dec 20 09:50:07 2010
Damien Gallop
MCIS Development & EOB
Development and the quest for gold continue.
Later... Mass scans in region of
197Au33 A/q=5.97, with graph of all theoretically
381
Tue Dec 21 09:43:22 2010
Damien Gallop
In Memoriam... Mike McDonald
At 5:00 this morning, after a lengthy battle
with cancer, Mike passed from this life to
his eternal reward. He has left us a great
382
Fri Dec 24 13:06:07 2010
Damien Gallop
Merry Christmas and Happy New Year
Our very best to all of you.
383
Fri Feb 18 11:05:50 2011
Keerthi Jayamanna
OLIS Problems
PE set point is ok but read back is half of
the real value.
384
Fri Feb 18 11:43:32 2011
Keerthi Jayamanna
IOS: EE Status
IOS:EE found damaged. It has been replaced
with IOS:SSEE-Michael B.
385
Tue Feb 22 18:52:53 2011
Keerthi Jayamanna
Ti+7 efficiency studies
2mm diameter Ti was installed to set the
optics. Later 0.0005 in thick foil will be
installed for real efficiency studies.
386
Tue Feb 22 18:54:43 2011
Keerthi Jayamanna
EE and SSEE
Both EE and SSEE problems were solved.
They are working OK now.
387
Wed Feb 23 22:29:48 2011
Keerthi Jayamanna
OLIS mahnet
Klixon at the OLIS bemding magnet is not
funtioning properly.
389
Fri Feb 25 17:27:11 2011
Keerthi Jayamanna
Titaniums efficiency test
Small peice of titanium wire is installed
and running aroung 100pA of Ti+7 at FC6.
OSAC are OPs taking data.
388
Fri Feb 25 17:27:11 2011
Keerthi Jayamanna
Titaniums efficiency test
Small piece of titanium foil 0.0005"
thick is installed and running around 100pA
of Ti+7 at FC6.
Goto page
Previous
1
,
2
,
3
...
20
, 21,
22
...
24
,
25
,
26
Next
ELOG V2.9.2-2455