  133   Fri Sep 11 23:42:45 2009 KeerthiOtherGeneralMCIS turbo pumpMCIS TP1 is not running well. Needs investigation
as soon as S1219 is completed.
Later... TP1 failed completely, and
 mcis_multi-state.png 
  132   Tue Sep 8 15:14:45 2009 Damien Gallop  Back from vacationI'm back from vacation. Physically, anyway.
Keerthi did comprehensive emittance scans
during Supernanogan Development over the
 magstab_off-on.pngmagstab_on_10-sep-2009.pngmagstab_on_14-sep-2009.png 
  131   Tue Aug 18 11:16:16 2009 Damien Gallop  MCIS "PV" PLC trip overnightAnother in the on-going saga of MCIS:PV1
trips occurred again this morning. The operators
recovered most of the vacuum devices except
 grab.SXu928.pnggrab.eG1166.pnggrab.di1170.png 
  130   Mon Aug 17 15:53:54 2009 Damien Gallop  MCIS mass scans & initial emittance scansHigh resolution zero to 25. Save file:
masscorr_mcis_090817-highres.txt
Ack! Elog server went down at ~17:00!!!
 11x 
  129   Mon Aug 17 13:58:35 2009 Damien Gallop  Supernanogan Development begins today for one weekSupernanogan Development begins. It will
be a marathon. Main goals are high-charge
emittance scans and RF frequency scans. Tall
 Picture_43.pnggrab.a30699.png 
  128   Fri Aug 14 13:53:34 2009 Damien Gallop  MWS 25Mg end of run dataMarco gave us the all-clear this morning
to shut down the MWS. We are preparing to
remove the MWS head from the Y-box and blank
 10x 
  127   Tue Aug 11 09:54:28 2009 Damien Gallop  MWS 25Mg operation overnight & MCIS cart installationAs noted earlier, the MWS beam dropped
out at some point after yesterday afternoon's
playtime, due to insufficient PE. Plasma
 grab.Z26532.pnggrab.Y26538.png 
  126   Mon Aug 10 18:29:32 2009 Damien Gallop  MWS source trip & restartWell, so it goes. As I was penning a note
for OPS, the source tripped. It easily reignited
with a little extra Ne. I left the flow slightly
 grab.q23803.png 
  125   Mon Aug 10 18:06:09 2009 Damien Gallop  MWS 25Mg reduce intensity with PESo... we have had this on-going problem
with intense Mg beam coating our optics.
Keerthi found a good recipe last week with
 grab.W23753.png 
  124   Mon Aug 10 17:42:18 2009 Damien Gallop  MWS 25Mg emittance scan with original settingsFinally, here is the "original"
beam. Can you tell the difference (side-by-side
at bottom)? I can't.
 6x 
  123   Mon Aug 10 17:20:55 2009 Damien Gallop  MWS 25Mg emittance scan with zeroed vertical steerersHere is a variation I thought might be
appropriate.
Data file: 090810_1724ILTEMIT.txt
 grab.k23573.pnggrab.m23577.pnggrab.v23582.pnggrab.U23599.png 
  122   Mon Aug 10 17:16:20 2009 Damien Gallop  MWS 25Mg emittance scan with downstream quads offHere is the emittance scan that Rick requested,
beam with Q4/5/6 off. Note that present numbers
for these quads do not match theoretical.
 grab.E23496.pnggrab.o23517.pnggrab.J23522.pnggrab.Q23526.png 
  121   Mon Aug 10 16:43:59 2009 Damien Gallop  MWS 25Mg emittance scan with slits openBefore proceeding, I nudged in each of
the slits, watching for first clipping. With
the current emittance (nice), the beam cleared
 grab.G23396.pnggrab.g23400.pnggrab.r23404.png 
  120   Mon Aug 10 16:36:33 2009 Damien Gallop  MWS 25Mg emittance scansA series of 25Mg emittance scans for Rick.
Starting scan with everything as-is,
i.e. slits closed.
 grab.d23286.pnggrab.w23291.pnggrab.U23295.pnggrab.U23312.pnggrab.q23316.png 
  119   Mon Aug 10 16:12:28 2009 Damien Gallop  MWS 25Mg operation over the weekendSummary: good.
Details: A trip occurred at some
point. I restarted the source over the weekende
 grab.m23211.pnggrab.F23215.png 
  118   Fri Aug 7 14:42:29 2009 Damien Gallop  MWS 25Mg beam reductionAround noon, Keerthi adjusted the PE down
to reduce the intensity of the Mg beam, as
we are running with attenuators in. He ended
 grab.jpa367.pnggrab.zFr371.pnggrab.PTd375.pnggrab.DYQ403.png 
  117   Fri Aug 7 10:16:38 2009 Damien Gallop  MWS 25Mg emittance scansWhile there is an SC cavity issue, I have
been repeating last evening's emittance scans.
Here is the best one. About 70nA of 25Mg
 6x 
  116   Thu Aug 6 17:02:00 2009 Damien Gallop  MWS 25Mg tuning to TIGRESS in progressTuning has been on-going through the day.
Here are a couple of emittance scans taken
in-between heartbeats. The first is zoomed
 7x 
  115   Wed Aug 5 11:29:51 2009 Damien Gallop  MWS operation overnight and 25Mg statusSo... there evidently was a power bump
overnight, because the stability power supply
was "disconnected" from the system.
 grab.G24908.pnggrab.h24912.pnggrab.T24916.pnggrab.W24925.pnggrab.x24953.png 
  114   Tue Aug 4 11:13:04 2009 Damien Gallop  MWS source tuning for 25Mg operationThe source stayed up overnight just fine,
with a little 25Mg beam on FC6. This morning
I did a few mass scans to get a fix on Mg
 6x 