|
ID |
Date |
Author |
Type |
Category |
Subject |
Text |
|
|
133
|
Fri Sep 11 23:42:45 2009 |
Keerthi | Other | General | MCIS turbo pump | MCIS TP1 is not running well. Needs investigation
as soon as S1219 is completed.
Later... TP1 failed completely, and |
|
|
132
|
Tue Sep 8 15:14:45 2009 |
Damien Gallop | | | Back from vacation | I'm back from vacation. Physically, anyway.
Keerthi did comprehensive emittance scans
during Supernanogan Development over the |
|
|
131
|
Tue Aug 18 11:16:16 2009 |
Damien Gallop | | | MCIS "PV" PLC trip overnight | Another in the on-going saga of MCIS:PV1
trips occurred again this morning. The operators
recovered most of the vacuum devices except |
|
|
130
|
Mon Aug 17 15:53:54 2009 |
Damien Gallop | | | MCIS mass scans & initial emittance scans | High resolution zero to 25. Save file:
masscorr_mcis_090817-highres.txt
Ack! Elog server went down at ~17:00!!! |
11x |
|
129
|
Mon Aug 17 13:58:35 2009 |
Damien Gallop | | | Supernanogan Development begins today for one week | Supernanogan Development begins. It will
be a marathon. Main goals are high-charge
emittance scans and RF frequency scans. Tall |
|
|
128
|
Fri Aug 14 13:53:34 2009 |
Damien Gallop | | | MWS 25Mg end of run data | Marco gave us the all-clear this morning
to shut down the MWS. We are preparing to
remove the MWS head from the Y-box and blank |
10x |
|
127
|
Tue Aug 11 09:54:28 2009 |
Damien Gallop | | | MWS 25Mg operation overnight & MCIS cart installation | As noted earlier, the MWS beam dropped
out at some point after yesterday afternoon's
playtime, due to insufficient PE. Plasma |
|
|
126
|
Mon Aug 10 18:29:32 2009 |
Damien Gallop | | | MWS source trip & restart | Well, so it goes. As I was penning a note
for OPS, the source tripped. It easily reignited
with a little extra Ne. I left the flow slightly |
|
|
125
|
Mon Aug 10 18:06:09 2009 |
Damien Gallop | | | MWS 25Mg reduce intensity with PE | So... we have had this on-going problem
with intense Mg beam coating our optics.
Keerthi found a good recipe last week with |
|
|
124
|
Mon Aug 10 17:42:18 2009 |
Damien Gallop | | | MWS 25Mg emittance scan with original settings | Finally, here is the "original"
beam. Can you tell the difference (side-by-side
at bottom)? I can't. |
6x |
|
123
|
Mon Aug 10 17:20:55 2009 |
Damien Gallop | | | MWS 25Mg emittance scan with zeroed vertical steerers | Here is a variation I thought might be
appropriate.
Data file: 090810_1724ILTEMIT.txt |
|
|
122
|
Mon Aug 10 17:16:20 2009 |
Damien Gallop | | | MWS 25Mg emittance scan with downstream quads off | Here is the emittance scan that Rick requested,
beam with Q4/5/6 off. Note that present numbers
for these quads do not match theoretical. |
|
|
121
|
Mon Aug 10 16:43:59 2009 |
Damien Gallop | | | MWS 25Mg emittance scan with slits open | Before proceeding, I nudged in each of
the slits, watching for first clipping. With
the current emittance (nice), the beam cleared |
|
|
120
|
Mon Aug 10 16:36:33 2009 |
Damien Gallop | | | MWS 25Mg emittance scans | A series of 25Mg emittance scans for Rick.
Starting scan with everything as-is,
i.e. slits closed. |
|
|
119
|
Mon Aug 10 16:12:28 2009 |
Damien Gallop | | | MWS 25Mg operation over the weekend | Summary: good.
Details: A trip occurred at some
point. I restarted the source over the weekende |
|
|
118
|
Fri Aug 7 14:42:29 2009 |
Damien Gallop | | | MWS 25Mg beam reduction | Around noon, Keerthi adjusted the PE down
to reduce the intensity of the Mg beam, as
we are running with attenuators in. He ended |
|
|
117
|
Fri Aug 7 10:16:38 2009 |
Damien Gallop | | | MWS 25Mg emittance scans | While there is an SC cavity issue, I have
been repeating last evening's emittance scans.
Here is the best one. About 70nA of 25Mg |
6x |
|
116
|
Thu Aug 6 17:02:00 2009 |
Damien Gallop | | | MWS 25Mg tuning to TIGRESS in progress | Tuning has been on-going through the day.
Here are a couple of emittance scans taken
in-between heartbeats. The first is zoomed |
7x |
|
115
|
Wed Aug 5 11:29:51 2009 |
Damien Gallop | | | MWS operation overnight and 25Mg status | So... there evidently was a power bump
overnight, because the stability power supply
was "disconnected" from the system. |
|
|
114
|
Tue Aug 4 11:13:04 2009 |
Damien Gallop | | | MWS source tuning for 25Mg operation | The source stayed up overnight just fine,
with a little 25Mg beam on FC6. This morning
I did a few mass scans to get a fix on Mg |
6x |