Entry  Tue Oct 14 08:31:53 2014, Brian Minato, Other, General, Water Flow Switch #3 
This entry was incorrectly added to the OLIS logbook.  it has been moved to the I3 logbook.
Entry  Sun Oct 11 17:09:52 2009, Keerthi, , , Vacuum with IOS:IV7 
IOS:IG4 reads 1.25 e-7 Torr and IOS:IG1 reads 9.8e-8 Torr with IOS:IV7 is open
IOS:IG4 reads 8.35 e-8 Torr and IOS:IG1 reads 7.49e-8 Torr with IOS:IV7 is closed
Entry  Fri Feb 25 17:27:11 2011, Keerthi Jayamanna, , , Titaniums efficiency test 
Small peice of titanium wire is installed and running aroung 100pA of Ti+7 at FC6.
OSAC are OPs taking data.
Entry  Fri Feb 25 17:27:11 2011, Keerthi Jayamanna, , , Titaniums efficiency test 
Small piece of titanium foil 0.0005" thick is installed and running around 100pA of Ti+7 at FC6.
OSAC are OPs taking data.
Entry  Sat Feb 26 22:06:03 2011, Keerthi Jayamanna, , , Ti+7 status 
90pA of Ti+7 is running smoothly. 22:05  Feb26th
Entry  Tue Feb 22 18:52:53 2011, Keerthi Jayamanna, , , Ti+7 efficiency studies 
2mm diameter Ti was installed to set the optics. Later 0.0005 in thick foil will be installed for real efficiency studies.
Entry  Thu May 14 12:02:09 2009, Damien Gallop, Routine, General, Testing 2 
My first OLIS elog entry.
Entry  Fri Oct 10 14:02:56 2014, Raymond Dube, Routine, General, Test with new Alga, ALPA 50W RF AMP ALPA-RF_AMP-50W.pdf
We did a test yesterday with the new Alga Microwave RF AMP, model # ALPA 50 Watt, serial # 130684 to be used for the MCIS.  We used the RF Generator
from MISTIC and set the frequency to 13.80 Ghz, note that the RF Generator was/is  limited to 16DB maxiumum RF output.
The RF cable that we used was from the 200W RF AMP, it has a 20DB SMA attenuator at the Generator end, so we could only get about 25 Watts maximum
Entry  Wed Sep 16 18:14:29 2009, Damien Gallop, , , Test scans for publication 2 19x
090916_1206ILTEMIT.txt
Graphics with "color" in the filename will look in print the same as "greyscale" files.
Entry  Tue Sep 15 16:56:03 2009, Damien Gallop, , , Test scans for publication grab.E19994.pnggrab.U19879-greyscale.pnggrab.U19879-cropped.png
Here are pix of the same scan: original, then greyscale, then cropped, using The GIMP. Not bad.
Entry  Thu May 14 11:07:33 2009, Hossein Rafighi, , , Test 
Testing!
Entry  Fri May 22 12:31:36 2009, Raymond Dubé, , , Test 
Hello world
Entry  Fri May 22 15:03:55 2009, Damien Gallop, Routine, General, Temporary fix on IOS:TP7 
Vacuum Group applied a temporary fix to the lower body seal on IOS:TP7, which we found last night to be leaking. Edi tells me that similar seals have
failed before. It's an O-ring, not a metal seal. The fix now was to marinate the outside seam with silicon grease and wrap with Teflon tape. We'll see
how that improves the backing line after a while.
Entry  Thu Jun 11 12:10:22 2009, Damien Gallop, Routine, General, Supernanogan status 
Pumping went well overnight. TP3 turned on around noon. Issues with Kepco communications.
Entry  Fri Jan 15 15:30:02 2010, keerthi, , , Supernanogan oven start up 
Voltage              Current             MCIC:IG1
0                            0                
      7.35e-8
Entry  Fri Jul 17 09:33:09 2009, Damien Gallop, , , Supernanogan epilogue grab.a24906.pnggrab.Q24916.png
There are the last couple of hours of Supernanogan Development for this set. Our run plan included 17On+ studies. Time will not permit it this time around.
Also, the emittance numbers of 16O and 18O are not distinctive enough as they stand to warrant studies of the in-between mass. Keerthi will run the emittance
data files through his software during post-analysis, and we'll develop our next run plan based on his conclusions.
Entry  Tue Sep 15 19:46:21 2009, Keerthi, Routine, General, Supernanogan emittance scans 9x
090915_1915ILTEMIT.txt = 17O +3,  4.4uA new tune, scanner offset +10V,  scanner scale 100nA , 100x50 matrix
090915_1929ILTEMIT.txt = same as above with 200x100 matrix
090915_1949ILTEMIT.txt = after tune tweaking (not optimal; for reference only)
Entry  Tue Feb 2 10:06:41 2010, Damien Gallop, , , Supernanogan development wind-up 9x
We ran 32S5+ overnight. Keerthi has been working with the new surface source oven for the last couple of weeks. His results to come. Meanwhile, here
are a stripchart of overnight beam plus a few panels after my tweaking. Slits are at 5mm position.
Observations:
Entry  Wed Jul 8 11:52:54 2009, Damien Gallop, Routine, General, Supernanogan development run plan for the remainder of this set 
* 18On+ emittance scans at present ion source settings: complete today.
* 18On+ frequency measurements: Thursday.
* 17O source gas: open end of Thursday.
Entry  Wed Jun 10 11:22:59 2009, Damien Gallop, Routine, General, Supernanogan development mass scans grab.t27875.pnggrab.R27900.pnggrab.H27444.png
Main event this morning so far: mass scans and post-scan analysis using Gabe's tools. We have a pretty good recipe now. Tight scan to mass 20 in progress.
Later... good scan. Geoff and I did a dry run of our presentations for Friday morning. We used the Auditorium computers, etc. After some small teething
pains, everything went well, including a cold start-up of the source. The 17O3+ emittance scan was taken quickly. Pretty good outcome anyway. The mass