OLIS Logbook General
  General, Page 18 of 26  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Datedown Author Type Category Subject Text Attachments
  173   Wed Oct 28 09:55:28 2009 Damien Gallop  Planned IOSIOC rebootControls is rebooting IOSIOC. I have inserted
MCIS:FC1 for the duration. Let's see what
comes of it all.
 Picture_1.pngPicture_2.png 
  172   Wed Oct 28 09:33:51 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnight cont'dBeam was quiet overnight. I noticed a slow
drift that seemed to follow the source pressure.
My best guess is that our source gas "regulator"
 Picture_1.png 
  171   Tue Oct 27 09:22:14 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnightI had optimized the RF yesterday, but the
source went into a dual-mode toggling regime.
It is hairline to find a nice point. I also
 Picture_7.pngPicture_8.pngPicture_3.pngPicture_4.png 
  170   Mon Oct 26 10:56:52 2009 Damien Gallop  MCIS on with 33S5+ on FC6 over the weekendOn Friday we left 33S5+ on FC6. The separator
magnet power supply tripped at some point
for unknown reason. The operators turned
 Picture_4.png 
  169   Fri Oct 23 09:55:41 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnight cont'dBeam stayed on quietly overnight, as did
the separator stability program. Periodic
pulsing continues to occur. No explanation
 Picture_2.pngPicture_3.png 
  168   Thu Oct 22 15:54:24 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnight cont'dThe Supernanogan was on overnight quietly.
FC6 went in this morning. (Didn't check if
fingers were involved.) I  now notice
 pulse.pngpulse-clip.pngpulse-tweak.png 
  167   Wed Oct 21 11:01:37 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnight cont'dI alsmost want to write, see yesterday's
entry! Source ran quietly with no interruptions.
FTR, the separator stability program is also
  
  166   Tue Oct 20 09:25:29 2009 Damien Gallop  MCIS on with 33S5+ on FC6 overnightThe source stayed up quietly overnight
with about 4enA on FC6. Once in a while a
little burp occurs, visible as small beam
  
  165   Mon Oct 19 10:09:13 2009 Damien Gallop  MCIS on with 33S5+ on FC6Switch on source for stats. Source lit
up perfectly. Slight adjustment on RF frequency.
 Picture_5.png 
  164   Thu Oct 15 21:06:10 2009 Keerthi  OLIS status33S development is completed.  A 3nA
of 33S+5 can be produced with 10W of RF power
and 2.5mm aperture.
  
  163   Thu Oct 15 09:43:00 2009 Damien Gallop  MCIS development with 33S5+Source started. 33S5+ beam on FC6 using
gas flow determined yesterday. At first blush,
it appears we need a slightly higher flow.
 Picture_3.png 
  162   Wed Oct 14 12:06:46 2009 Damien Gallop  MCIS development with 33S5+MCIS was running with background only.
Prepare to open SO2 source gas...
MCIS:IG1 = 5.4e-8 Torr
 grab.w30542.png 
  161   Wed Oct 14 09:52:09 2009 Damien Gallop  MCIS development with 33S5+ todayThe source is on. There is background beam
on FC6 presently, less than yesterday. That's
probably a good thing. Let it cook for a
 Picture_6.png 
  160   Tue Oct 13 14:14:17 2009 Damien Gallop  MCIS setup for 33S5+Keerthi has reinstalled the SO2 source
gas bottle onto MCIS. Presently it is closed
off to the source. We have restarted the
 Picture_2.pngPicture_3.pngPicture_4.pngPicture_5.png 
  159   Sun Oct 11 17:11:31 2009 Keerthi  MCIS turbo pumps power levelsMCIS:TP1 = 12W
MCIS:TP2 = 11W
  
  158   Sun Oct 11 17:09:52 2009 Keerthi  Vacuum with IOS:IV7IOS:IG4 reads 1.25 e-7 Torr and IOS:IG1
reads 9.8e-8 Torr with IOS:IV7 is open
IOS:IG4 reads 8.35 e-8 Torr and IOS:IG1
  
  157   Sun Oct 11 13:17:37 2009 Keerthi  Neon Leak closedNeon leak close for upcoming 33S development.   
  156   Sun Oct 11 13:16:39 2009 Keerthi  MCIS:TP3 was offMCIS TP3 foumd off by 1:00 pm.  Restarted
without a problem
Before TP3 is on MCIS:IG1 is 5.47e-8
  
  155   Fri Oct 9 16:33:45 2009 Keerthi  33S developmentSO2 gas line is connected
again. Leak hand valve is closed.
  
  154   Thu Oct 8 09:39:52 2009 Damien Gallop  CSB Development with MCISFriedhelm and Marco have requested 20Ne2+
from the Supernanogan, and plan to bring
up the same from the CSB today. I am beginning
 MCIS_HV_Conditioning.png 
ELOG V2.9.2-2455