Entry  Sat Jun 12 10:20:14 2010, Damien Gallop, , , 15N4+ to TIGRESS done 13x

Delivery to TIGRESS ended this morning as scheduled. ICR took nice emittance scans and is completing a target snapshot now. Canister still at -22"Hg and MCIS at 7.3e-8 Torr.

Chance to snap some wirescans. Attached.

Entry  Fri Jun 11 09:21:24 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_1.png

Delivery of 15N4+ to TIGRESS continues. Source gas canister is still at ~-22"Hg, and MCIS pressure is 7.2e-8 Torr. ICR reported intensity drops a couple of times this morning. The attached Stripchart suggests beam from the source is down to about a third from status quo. We will look into it now.

Entry  Thu Jun 10 09:17:42 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_1.pngPicture_2.pngPicture_3.png

Delivery to TIGRESS began yesterday or so. ICR reported beam intensity drops overnight. I'll look at it presently. Meanwhile, canister pressure is still ~-22"Hg and MCIS pressure is 7.09e-8 Torr.

Later... Check source at request of ICR. It looks mighty fine. Slight tweaks on RF, but really no great change. FC6 was and is 200enA, though it was around 80enA this morning.

Entry  Wed Jun 9 10:07:33 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_7.png

Setup into ISAC-II began last night. Tuning is in progress now. Beam on FC6 overnight. Canister pressure is -22"Hg and MCIS pressure=7.1e-8 Torr. Pressure showed correlation with temperature. It is overcast today and cool, suggesting a fairly flat response today.

Entry  Tue Jun 8 09:27:54 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_4.pngPicture_5.png

User tuning began Sunday night. Beam physics expert chose to retire the IOS:Q1 defeat, as he did not know until yesterday that it existed. He discovered it after attempting to retune yesterday around noon from scratch and making a mess, notwithstanding Keerthi's clear instruction to leave it alone. He also does not know that Rick developed a tune for this, which provides cleaner transmission than the "book" tune. Pity. Presently there are some 75enA of beam at FC6. That should be enough. Note that there were some 90enA with the "defeat" tune in place, prior to changing the IOS tune. Canister is at ~-22"Hg, and MCIS pressure at ~7.0e-8 Torr at ~09:00.. ICR is tuning through presently.

Entry  Mon Jun 7 10:36:14 2010, Damien Gallop, , , 15N setup over the weekend Picture_2.png

Keerthi set up the Supernanogan for 15N operation and destined for TIGRESS, using two source gas options: a miniature bottle of enriched 15N2 and a canister with a charge of research-grade 14N2. The canister is similar to the one we used for the 33S run to DRAGON, which finished Saturday morning. Canister is at -22"Hg and MCIS at 7.27e-8 Torr. A couple of beam stability tests were conducted at 15N4+ and 15N6+. Bob can choose which one he prefers to use. 15N4+ is selected and tuned through IOS up to the RFQ presently (~10:30 am).

Later... Bob reported at the Beam Delivery meeting that the 33S6+ beam was a very nice beam. We appreciate hearing it.

Entry  Fri Jun 4 09:30:48 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png

Delivery of 33S6+ continues to DRAGON for the final day. Some online tuning of the line overnight. Source gas canister pressure remains at ~-20"Hg, and MCIS pressure is at 7.1e-8 Torr.

Entry  Thu Jun 3 09:29:11 2010, Damien Gallop, , , 33S to DRAGON Picture_1.png

33S6+ delivery to DRAGON continues until Saturday morning. All the signs are that beam is excellent. Source gas canister is still at ~-20"Hg, and MCIS vacuum is at 7.0e-8 Torr.

Entry  Wed Jun 2 09:19:04 2010, Damien Gallop, , , 33S to DRAGON 

33S6+ delivery to DRAGON continues. It is Maintenance Day for everybody else today. Source gas canister pressure = -20"Hg. MCIS pressure = 7.7e-8 Torr.

Entry  Tue Jun 1 09:12:39 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png

33S6+ delivery to DRAGON continues. Looks like there was an RF tweak overnight. Source gas canister still at ~-20"Hg. MCIS vacuum at 7.4e-8 Torr.

Entry  Mon May 31 09:18:39 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png

Delivery of 33S6+ to DRAGON continues. A couple of RF tweaks done over the weekend. Source gas canister pressure at -20"Hg. MCIS pressure at 7.3e-8 Torr. At this rate, we could deliver 33S until approximately forever.

Entry  Fri May 28 11:02:59 2010, Damien Gallop, , , 33S to DRAGON Picture_1.png

Beam tuning in progress. Source gas canister at -20"Hg. MCIS pressure at 7.62e-8 Torr.

Entry  Thu May 27 09:11:10 2010, Damien Gallop, , , 33S Development and Handover Picture_2.png

33S on FC6 overnight. Preparing to send beam to DRAGON now, and confirm isotope.

Source gas pressure gauge on canister = -20"Hg. MCIS pressure = 7.8e-8 Torr.

Entry  Wed May 26 18:16:10 2010, Damien Gallop, , , 33S Development grab.Cm6004.png

Some 3enA of beam on FC6 presently. Let it sit.

Entry  Tue May 25 22:02:41 2010, Keerthi Jayamanna, , , 33S spectrum 

33S spectrum is saved as 33S_spectrum.dat 

Entry  Tue May 25 11:58:02 2010, Keerthi Jayamanna, , , 33S dev 

after 24 hours background spectrum saved as "BackgroungNo33S003.dat"

RF Amplitude :7.767 , RFoutput power= 5W, Output power (dB)=36.4

Entry  Tue May 25 11:28:00 2010, Keerthi Jayamanna, , , 33D dev 

after 24 hours background spectrum saved as "BackgroungNo33S002.dat"

RF Amplitude :1.553 , RFoutput power= 0, Output power (dB)=0  

Entry  Tue May 25 00:19:18 2010, Keerthi Jayamanna, , , 33S 

 

Finally got something going. YCB1 short to the ground. YCB common plate connected to YCB1 power supply. We were lucky. Polarity was right. Ran the source with no 33S.
Saved file as “backgroundNo33S.dat” No optics set yet. SO2 connected not open yet. 33S 17% is in the oven, but not heated yet.
Entry  Mon May 24 22:42:51 2010, Keerthi Jayamanna, , , 33S development Picture_1.png

Tried to see the background before 33S installation. Found few problems: MCIS:YCB1 does not hold more than 58V.

Very difficult to transport the beam without YCB1. Need to find a solution. Open and fix it is not an option even though we have a ready spare. It will take two weeks to get the vacuum back.

------------------------------

Outgoing TIGRESS experiment was the occasion for another ISAC milestone, 8MeV/u through the SCC for the first time just around midnight last Friday, May 21st. This also represented the first 8MeV/u beam to an experiment. And we can proudly say that OLIS beam was used. TIGRESS run ended at 08:30 as scheduled. Attached is a trar graph of beam on FC6, snapped periodically throughout the run. As before, you can see a small daily variation likely related to temperature of NA-LCW. There were reports of HPL tests this past Thursday and Friday. Evidently no effect over here.

 

Entry  Wed May 19 09:55:51 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for TIGRESS Picture_6.png

ISAC-I tuning done yesterday. TBC today into ISAC-II. Beam very nice overnight.

ELOG V2.9.2-2455