ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
166
|
Tue Oct 20 09:25:29 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight | The source stayed up quietly overnight
with about 4enA on FC6. Once in a while a
little burp occurs, visible as small beam |
|
167
|
Wed Oct 21 11:01:37 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd | I alsmost want to write, see yesterday's
entry! Source ran quietly with no interruptions.
FTR, the separator stability program is also |
|
168
|
Thu Oct 22 15:54:24 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd | The Supernanogan was on overnight quietly.
FC6 went in this morning. (Didn't check if
fingers were involved.) I now notice |
  |
169
|
Fri Oct 23 09:55:41 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd | Beam stayed on quietly overnight, as did
the separator stability program. Periodic
pulsing continues to occur. No explanation |
 |
170
|
Mon Oct 26 10:56:52 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 over the weekend | On Friday we left 33S5+ on FC6. The separator
magnet power supply tripped at some point
for unknown reason. The operators turned |
|
171
|
Tue Oct 27 09:22:14 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight | I had optimized the RF yesterday, but the
source went into a dual-mode toggling regime.
It is hairline to find a nice point. I also |
   |
172
|
Wed Oct 28 09:33:51 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd | Beam was quiet overnight. I noticed a slow
drift that seemed to follow the source pressure.
My best guess is that our source gas "regulator" |
|
173
|
Wed Oct 28 09:55:28 2009 |
Damien Gallop | | | Planned IOSIOC reboot | Controls is rebooting IOSIOC. I have inserted
MCIS:FC1 for the duration. Let's see what
comes of it all. |
 |
174
|
Thu Oct 29 09:42:23 2009 |
Damien Gallop | | | IOSIOC work in progress | Yesterday there was an IOSIOC reboot for
a purpose. It was an opportunity to demonstrate
to Controls that IOSIOC reboots materially |
|
175
|
Fri Oct 30 09:44:49 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight | Controls finished with IOSIOC work yesterday.
ICR had restored most optics. I restarted
the source last evening. As you can see below, |
   |
176
|
Mon Nov 2 09:32:40 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 over the weekend | Beam came up nicely on Friday, and
stayed up quuietly over the weekend. Note
the absence of periodic spikes in the separator |
   |
177
|
Mon Nov 2 17:42:54 2009 |
Damien Gallop | | | MCIS online with 17O3+ on FC6 | As noted earlier, we have opened the OLIS
cage and set up the source gases for 17O
operation. It will take a while for the SO2 |
|
178
|
Tue Nov 3 09:25:31 2009 |
Damien Gallop | | | MCIS online with 17O3+ on FC6 overnight | We completed 33S operation last night,
and roughed in a setup for 17O. We had 17O3+
on FC6 overnight; chart attached. It grew |
|
179
|
Wed Nov 4 09:46:07 2009 |
Damien Gallop | | | MCIS online with 17O3+ on FC6 for development | Beam stayed up overnight nicely. Development
today. RF scans in progress now.
Later... scanning done for the moment. |
9x |
180
|
Thu Nov 5 09:45:03 2009 |
Damien Gallop | | | MCIS online with 17O3+ on FC6 overnight | Beam was quiet overnight. Keerthi touched
up the tune this morning, and it is quieter
yet and a little more of it too. |
|
181
|
Fri Nov 6 11:17:54 2009 |
Damien Gallop | | | 17O3+ setup to DRAGON | As noted, we handed over the beam to our
users yesterday by noon. Setup to DRAGON
is continuing. The report this morning that |
|
183
|
Mon Nov 9 09:30:10 2009 |
Damien Gallop | | | 17O3+ beam to DRAGON | Beam delivery continued through the weekend.
As noted on Saturday, current dropped precipitously
due to source gas pressure. We have 2.3e-6eµA |
|
184
|
Tue Nov 10 09:36:39 2009 |
Damien Gallop | | | 17O3+ beam to DRAGON continuing | Beam ran well overnight. Last evening Vacuum
Group diagnosed and repaired a catastrophic
leak in the ILT cross region. You can see |
|
185
|
Fri Nov 13 10:26:07 2009 |
Damien Gallop | | | 17O3+ beam to DRAGON continuing | Beam and energy changes continued over
the weekend. The ICR reports that things
are going swimmingly, and that the users |
 |
186
|
Mon Nov 16 10:00:41 2009 |
Damien Gallop | | | 17O3+ beam to DRAGON end of run this morning | DRAGON declared EOB at around 08:00 today.
Source and beam were switched to 21Ne4+ for
calibration studies. |
|