293
Sat Jun 12 10:20:14 2010
Damien Gallop
15N4+ to TIGRESS done
Delivery to TIGRESS ended this morning
as scheduled. ICR took nice emittance
scans and is completing a target snapshot
13x
292
Fri Jun 11 09:21:24 2010
Damien Gallop
15N4+ to TIGRESS
Delivery of 15N4+ to TIGRESS continues.
Source gas canister is still at ~-22"Hg,
and MCIS pressure is 7.2e-8 Torr. ICR reported
291
Thu Jun 10 09:17:42 2010
Damien Gallop
15N4+ to TIGRESS
Delivery to TIGRESS began yesterday
or so. ICR reported beam intensity drops
overnight. I'll look at it presently. Meanwhile,
290
Wed Jun 9 10:07:33 2010
Damien Gallop
15N4+ to TIGRESS
Setup into ISAC-II began last night. Tuning
is in progress now. Beam on FC6 overnight.
Canister pressure is -22"Hg and MCIS
289
Tue Jun 8 09:27:54 2010
Damien Gallop
15N4+ to TIGRESS
User tuning began Sunday night. Beam physics
expert chose to retire the IOS:Q1 defeat,
as he did not know until yesterday that it
288
Mon Jun 7 10:36:14 2010
Damien Gallop
15N setup over the weekend
Keerthi set up the Supernanogan for 15N
operation and destined for TIGRESS, using
two source gas options: a miniature bottle
287
Fri Jun 4 09:30:48 2010
Damien Gallop
33S to DRAGON
Delivery of 33S6+ continues to DRAGON for
the final day. Some online tuning of the
line overnight. Source gas canister pressure
286
Thu Jun 3 09:29:11 2010
Damien Gallop
33S to DRAGON
33S6+ delivery to DRAGON continues until
Saturday morning. All the signs are that
beam is excellent. Source gas canister is
285
Wed Jun 2 09:19:04 2010
Damien Gallop
33S to DRAGON
33S6+ delivery to DRAGON continues. It
is Maintenance Day for everybody else today.
Source gas canister pressure = -20"Hg.
284
Tue Jun 1 09:12:39 2010
Damien Gallop
33S to DRAGON
33S6+ delivery to DRAGON continues. Looks
like there was an RF tweak overnight. Source
gas canister still at ~-20"Hg. MCIS
283
Mon May 31 09:18:39 2010
Damien Gallop
33S to DRAGON
Delivery of 33S6+ to DRAGON continues.
A couple of RF tweaks done over the weekend.
Source gas canister pressure at -20"Hg.
282
Fri May 28 11:02:59 2010
Damien Gallop
33S to DRAGON
Beam tuning in progress. Source gas canister
at -20"Hg. MCIS pressure at 7.62e-8
Torr.
281
Thu May 27 09:11:10 2010
Damien Gallop
33S Development and Handover
33S on FC6 overnight. Preparing to send
beam to DRAGON
now, and confirm isotope.
280
Wed May 26 18:16:10 2010
Damien Gallop
33S Development
Some 3enA of beam on FC6 presently. Let
it sit.
279
Tue May 25 22:02:41 2010
Keerthi Jayamanna
33S spectrum
33S spectrum is saved as 33S_spectrum.dat
278
Tue May 25 11:58:02 2010
Keerthi Jayamanna
33S dev
after 24 hours background spectrum saved
as "BackgroungNo33S003.dat"
RF Amplitude :7.767 , RFoutput power=
277
Tue May 25 11:28:00 2010
Keerthi Jayamanna
33D dev
after 24 hours background spectrum saved
as "BackgroungNo33S002.dat"
RF Amplitude :1.553 , RFoutput power=
276
Tue May 25 00:19:18 2010
Keerthi Jayamanna
33S
Finally
got something going. YCB1 short to the ground.
275
Mon May 24 22:42:51 2010
Keerthi Jayamanna
33S development
Tried to see the background before 33S
installation. Found few problems: MCIS:YCB1
274
Wed May 19 09:55:51 2010
Damien Gallop
20Ne1+ at 40.8keV for TIGRESS
ISAC-I tuning done yesterday. TBC today