  2   Fri Dec 19 13:07:25 2003 Willy AnderssonMaintenanceTo-Do list for M9SOLI had distributed this list by email earlier
this month. I have added
a few items at the bottom. I am posting it
 M9Blist3.txt 
  11   Wed Apr 21 09:57:59 2004 Willy AnderssonStart UpSystem statusBuffer tank pressure is down to about 6 psig.
Too low to keep up
with liquefaction requirements to build LHe
  
  14   Sun Apr 25 21:41:00 2004 Willy AnderssonQuench RecoveryTrip on PL Temp.Got pager call at 16:20 this afternoon. Solenoid
had tripped on PL 
temperature. Arrived at about 17:00. Did
  
  26   Wed May 5 23:57:38 2004 Willy AnderssonQuench RecoveryPowerleads warming up again.Got a page from Don Flemming at about 18:50
wondering why the power
lead temperatures were rising. See attachment
 may5_04_1800.BMP 
  27   Thu May 6 09:32:13 2004 Willy AnderssonQuench RecoveryAdditional notes from last night power lead problems.When performing last nights refrigerator adjustments
I also increased the 
compressor discharge pressure to 11.25 barA.
  
  29   Fri Jun 25 12:36:04 2004 Willy AnderssonQuench RecoveryCompressor unloaded etc.At about 09:30 this morning I noticed the
sound coming from the compressor 
building seemed louder than usual. After
  
  30   Fri Jun 25 14:20:58 2004 Willy AnderssonQuench RecoverySwitch to series modeAt about 14:00 solenoid temps dipping below
8 K. Trace of LHe level (dense 
gas) starting to show. Switching to series
  
  31   Tue Jun 29 14:59:46 2004 Willy AnderssonNormal RunningRemoved jumper on vacuum controller.Tuesday 14:55

Removed jumper on back of PIC 901. This jumper
  
  40   Sat Aug 7 22:37:04 2004 Willy AnderssonQuench RecoveryCompressor tripped off.Got a call at about 10:00 this morning, the
whole system had tripped off. 
No power bumps or other disturbances. When
  
  41   Sat Aug 7 23:40:47 2004 Willy AnderssonQuench RecoveryEnergizing solenoid23:39 Powerleads cold, LHe level over 40%
and rising. Energizing solenoid 
to 500 Amps, ramp rate 60. Checking compressor
  
  47   Thu Sep 2 21:58:34 2004 Willy AnderssonQuench RecoverySwitch to series coolingSolenoid had tripped on powerlead overtemp
at about 09:00 this morning. 
Doug recovered the system to // cooling.
  
  86   Sun Nov 28 10:15:18 2004 Willy AnderssonQuench RecoveryPowerlead quench ?Got page very early this morning. Couldn't
come in til 08:30. System was 
in idle running mode and someone had reset
  
  101   Thu Jun 9 21:41:25 2005 Willy AnderssonQuench RecoveryTrying to achieve stable cooling.From about 08:00 to 15:00

See Doug's previous entry for quench recovery
  
  107   Tue Jul 19 16:13:32 2005 Willy AnderssonQuench Recoveryswitch to series modeCR_6KS_M down to 11 K.
Switched to series mode.
Started small flow to power leads to get
  
  108   Tue Jul 19 18:09:56 2005 Willy AnderssonQuench RecoveryQuench IIMachine trip just as I was exiting the TRIUMF
gate. QRL said cold box fault 
as did red lite on compressor. At cold box
  
  109   Sun Aug 14 10:03:13 2005 Willy AnderssonNormal RunningSystem stableNo experiment running in M9B.

Solenoid current is zero and power supply
  
  110   Mon Oct 31 07:48:57 2005 Willy AnderssonQuench Recoverywhat a fine entryKeep IT safe boys   
  111   Wed Nov 2 10:17:27 2005 Willy AnderssonStart UpM9B helium refrigerator and solenoid cooldownStarted M9B MYCOM helium compressor circulating
helium through system last 
Friday. Right hand purifier was regenerated
  
  125   Tue Jun 13 15:52:46 2006 Willy AnderssonQuench RecoveryDoug has reduced and now closed CV155.Now in full // cold return mode.
Had just talked with Curtis, He said thta
he has already informed the 
  
  126   Tue Jun 13 16:04:33 2006 Willy AnderssonQuench RecoveryTIC 121 set to auto mode    