Entry  Tue Jun 13 15:52:46 2006, Willy Andersson, Quench Recovery, Doug has reduced and now closed CV155. 
Now in full // cold return mode.
Had just talked with Curtis, He said thta he has already informed the 
experimentors that the solenoid will not be ready until tommorow, so he 
Entry  Tue Jun 13 10:54:27 2006, Doug Preddy, Quench Recovery, Compressor tripped off 
No indicator lights etc as to why the compressor tripped. The only  light 
was a cold box fault. I had to shut off the main breaker before the 
compressor would come back on.
Entry  Tue May 30 14:36:41 2006, Doug Preddy, Normal Running, power leads warming 
power leads warming. closed HIC 142, then re-opened. temps falling
Entry  Fri May 26 14:34:24 2006, Doug Preddy, Start Up, Ready to run 
Solenoid is cold, liquid level is 35%, power leads cold and seem stable.
Added one bottle helium to buffer tank. Pressure is 7 psi..
Entry  Fri May 26 10:03:03 2006, Doug Preddy, Start Up, Started flow to power leads 
Started flow to power leads.
Liquid level 15%
Entry  Fri May 26 08:45:38 2006, Doug Preddy, Start Up, Changed to series mode 
Changed to series mode.
Liquid level building.
Entry  Fri May 26 07:29:54 2006, Doug Preddy, Start Up, CV155 closed 
CV155 closed.
Temps about 15K
Entry  Thu May 25 07:34:18 2006, Doug Preddy, Start Up, switched to parallel cold return 
switched to parallel cold return
Entry  Tue May 23 08:44:28 2006, Doug Preddy, Start Up, Started turbines 
Solenoid and cold box were pumped out last Tuesday. Cold box roughing pump 
initially would not start. had to retighten all wires on the contactor in 
the Sulzer control panel (RP900).
Entry  Thu Dec 22 15:10:44 2005, Doug Preddy, Shut Down, shut down system 
shuttting down the system. isolated cold box by closing v135. preparing to 
pump out cold box.
Entry  Mon Dec 12 09:24:29 2005, Doug Preddy, Quench Recovery, Solenoid Quench on power lead temp 
The solenoid tripped on power lead temps at about 9:15. I am recovering it 
from it's all around mode into parallel cold return.
Entry  Tue Nov 15 07:25:10 2005, Doug Preddy, Normal Running, power supply problem 
Saturday November 12 the solenoid power supply ramped itself down to zero. 
It would not ramp up unless the ramp rate was set to 30 minutes. At this 
setting the power supply ramped up to the required current. It seems to 
Entry  Thu Nov 3 09:27:16 2005, Doug Preddy, Quench Recovery, started flow to solenoid 
started flow to solenoid in parallel cold return.
Entry  Thu Nov 3 06:19:50 2005, Doug Preddy, Quench Recovery, restart system 
Last night at about 7:00 there was a large power bump that shut the 
compressor and water pump off. I came in this morning and am restarting the 
system.
Entry  Wed Nov 2 10:17:27 2005, Willy Andersson, Start Up, M9B helium refrigerator and solenoid cooldown 
Started M9B MYCOM helium compressor circulating helium through system last 
Friday. Right hand purifier was regenerated previously, LN2 fill system 
started and flow started from buffer through purifier to low pressure 
Entry  Mon Oct 31 07:48:57 2005, Willy Andersson, Quench Recovery, what a fine entry 
Keep IT safe boys
Entry  Sun Aug 14 10:03:13 2005, Willy Andersson, Normal Running, System stable 
No experiment running in M9B.

Solenoid current is zero and power supply not armed.
Entry  Tue Jul 19 18:09:56 2005, Willy Andersson, Quench Recovery, Quench II 
Machine trip just as I was exiting the TRIUMF gate. QRL said cold box fault 
as did red lite on compressor. At cold box panel all turbine red lites were 
on and compressed air failure lite was on. But there was no problems with 
Entry  Tue Jul 19 16:13:32 2005, Willy Andersson, Quench Recovery, switch to series mode 
CR_6KS_M down to 11 K.
Switched to series mode.
Started small flow to power leads to get them cold.
Entry  Mon Jul 18 15:51:17 2005, Doug Preddy, Quench Recovery, Compressor restarted, flow to solenoid 
Recovered the vacuum in the solenoid, then started the compressor.
Started flow to solenoid in parallel warm return.