  166  
 | 
Thu Oct  5 14:53:54 2006 | 
Doug Preddy | Start Up | Switched to series mode |   | 
   | 
| 
  165  
 | 
Thu Oct  5 11:51:53 2006 | 
Doug Preddy | Start Up | Adde 2 bottles UHP Helium | Valved off purifiers, but left LN2 on. | 
   | 
| 
  164  
 | 
Thu Oct  5 10:26:26 2006 | 
Doug Preddy | Start Up | switched to parallel cold return |   | 
   | 
| 
  163  
 | 
Wed Oct  4 18:10:18 2006 | 
Willy Andersson | Start Up | Quick check on system | System in good // warm return mode, temps 
coming down nicely. BCP2 cryopump 
 
does not look too healthy, temperature is | 
   | 
| 
  162  
 | 
Wed Oct  4 07:29:04 2006 | 
Doug Preddy | Start Up | Starting cool down | Started compressor yesterday with flow through 
the purifier overnight.
 
Starting tubines this morning in parallel | 
   | 
| 
  161  
 | 
Thu Aug 17 19:45:27 2006 | 
Willy Andersson | Quench Recovery | switch to series cooling | Temps of flow returning from solenoid flat 
lined at about 10K.
 
Gradually closed CV155.
 | 
   | 
| 
  160  
 | 
Thu Aug 17 08:04:44 2006 | 
Doug Preddy | Quench Recovery | Solenoid tripped at about 3:00 this morning | restarting system.
 
Compressor would not start. Idid not see 
anything that would not let it 
 | 
   | 
| 
  159  
 | 
Tue Aug 15 15:39:27 2006 | 
Willy Andersson | Quench Recovery | switched to parallel cold return | Return flow temps from solenoid about 40K, 
TIC121 at about 40K so switching 
 
to //cold return.
 | 
   | 
| 
  158  
 | 
Tue Aug 15 08:45:56 2006 | 
Doug Preddy | Quench Recovery | restarted the compressor | Solenoid tripped off Sunday. Restarted compressor 
and cool down of cold box. | 
   | 
| 
  157  
 | 
Thu Aug 10 20:26:09 2006 | 
Willy Andersson | Quench Recovery | solenoid energized | Powerleads seem stable. | 
   | 
| 
  156  
 | 
Thu Aug 10 16:33:11 2006 | 
Willy Andersson | Quench Recovery | Flow to solenoid tripped on powerlead temperature. | Power lead temps were drifting up, tried to 
tweak TIC121 and HIC141 to 
 
unstall powerlead flow. Got quench. Restarted | 
   | 
| 
  155  
 | 
Thu Aug 10 08:33:44 2006 | 
Doug Preddy | Normal Running | Running low on helium | Temperture okay, but there are fluctuation 
in the power leads. PIC229 is 
 
trying to charge. The buffer tank pressure | 
   | 
| 
  154  
 | 
Wed Aug  9 07:50:49 2006 | 
Doug Preddy | Quench Recovery | Switched to series mode. | Cool down continues. | 
   | 
| 
  153  
 | 
Wed Aug  9 06:59:43 2006 | 
Willy Andersson | Quench Recovery | more // cold return stuff | About 21:00 last night the solenoid temps 
had not changed much, pretty well 
 
flat lined. I guess my reducing CV155 stalled | 
   | 
| 
  152  
 | 
Wed Aug  9 06:44:58 2006 | 
Willy Andersson | Quench Recovery | // cold mode cooling continues. | After restarting flow to the solenoid yesterday 
in // cold return mode 
 
TIC121 just refused to go lower than about | 
   | 
| 
  151  
 | 
Tue Aug  8 07:27:49 2006 | 
Doug Preddy | Quench Recovery | Solenoid Quench at about 6:00 this morning | No indication of problem. Turbines still running, 
but no flow to solenoid. 
 
Started flow. Solenoid ~20K. | 
   | 
| 
  150  
 | 
Sat Jul 29 09:38:06 2006 | 
Doug Preddy | Quench Recovery | power leads cooled | opened power lead flow about 40 minutes ago. 
~12K will let them stablize. 
 
LHE level >20% | 
   | 
| 
  149  
 | 
Sat Jul 29 05:30:28 2006 | 
Doug Preddy | Quench Recovery | switched to series mode | Temps bottomed out at ~16K. Switching to series 
mode. | 
   | 
| 
  148  
 | 
Fri Jul 28 20:39:40 2006 | 
Doug Preddy | Quench Recovery | Restarting refrigerator | Solenoid quenched at about 6:00 tonight.
 
I restarted the compressor, then the cold 
box and turbines. When cold box 
 | 
   | 
| 
  147  
 | 
Sat Jul 22 06:34:14 2006 | 
Experimentor | Quench Recovery | looking good | Donald Arseneau reporting.
 
 
It is looking pretty good, so I came back | 
   |