|  Thu Oct  5 11:51:53 2006, Doug Preddy, Start Up, Adde 2 bottles UHP Helium | 
| Valved off purifiers, but left LN2 on. | 
|  Thu Oct  5 10:26:26 2006, Doug Preddy, Start Up, switched to parallel cold return | 
|  | 
|  Wed Oct  4 18:10:18 2006, Willy Andersson, Start Up, Quick check on system | 
| System in good // warm return mode, temps coming down nicely. BCP2 cryopump does not look too healthy, temperature is just over 20K, very close to low
 set point.
 | 
|  Wed Oct  4 07:29:04 2006, Doug Preddy, Start Up, Starting cool down | 
| Started compressor yesterday with flow through the purifier overnight. Starting tubines this morning in parallel warm return
 | 
|  Thu Aug 17 19:45:27 2006, Willy Andersson, Quench Recovery, switch to series cooling | 
| Temps of flow returning from solenoid flat lined at about 10K. Gradually closed CV155.
 Then switched to series cooling.
 | 
|  Thu Aug 17 08:04:44 2006, Doug Preddy, Quench Recovery, Solenoid tripped at about 3:00 this morning | 
| restarting system. Compressor would not start. Idid not see anything that would not let it
 start. Pushed rest button upstairs, and reset contactor. Compressor started.
 | 
|  Tue Aug 15 15:39:27 2006, Willy Andersson, Quench Recovery, switched to parallel cold return | 
| Return flow temps from solenoid about 40K, TIC121 at about 40K so switching to //cold return.
 Starting with slightly reduced flow through cold returns, CV145 and CV147
 | 
|  Tue Aug 15 08:45:56 2006, Doug Preddy, Quench Recovery, restarted the compressor | 
| Solenoid tripped off Sunday. Restarted compressor and cool down of cold box. | 
|  Thu Aug 10 20:26:09 2006, Willy Andersson, Quench Recovery, solenoid energized | 
| Powerleads seem stable. | 
|  Thu Aug 10 16:33:11 2006, Willy Andersson, Quench Recovery, Flow to solenoid tripped on powerlead temperature. | 
| Power lead temps were drifting up, tried to tweak TIC121 and HIC141 to unstall powerlead flow. Got quench. Restarted series flow, building LHe
 level.
 | 
|  Thu Aug 10 08:33:44 2006, Doug Preddy, Normal Running, Running low on helium | 
| Temperture okay, but there are fluctuation in the power leads. PIC229 is trying to charge. The buffer tank pressure is just >0 psi. I will lower the
 liquid level to 40% to allow some helium to boil off into the buffer tank.
 | 
|  Wed Aug  9 07:50:49 2006, Doug Preddy, Quench Recovery, Switched to series mode. | 
| Cool down continues. | 
|  Wed Aug  9 06:59:43 2006, Willy Andersson, Quench Recovery, more // cold return stuff | 
| About 21:00 last night the solenoid temps had not changed much, pretty well flat lined. I guess my reducing CV155 stalled the cooling. Called Don
 Arseneau and asked him to increase CV155 to about 80% open. Temps slowly
 | 
|  Wed Aug  9 06:44:58 2006, Willy Andersson, Quench Recovery, // cold mode cooling continues. | 
| After restarting flow to the solenoid yesterday in // cold return mode TIC121 just refused to go lower than about 29K even when we closed CV155
 all the way. Tried various things, switching to // warm return, changing
 | 
|  Tue Aug  8 07:27:49 2006, Doug Preddy, Quench Recovery, Solenoid Quench at about 6:00 this morning | 
| No indication of problem. Turbines still running, but no flow to solenoid. Started flow. Solenoid ~20K.
 | 
|  Sat Jul 29 09:38:06 2006, Doug Preddy, Quench Recovery, power leads cooled | 
| opened power lead flow about 40 minutes ago. ~12K will let them stablize. LHE level >20%
 | 
|  Sat Jul 29 05:30:28 2006, Doug Preddy, Quench Recovery, switched to series mode | 
| Temps bottomed out at ~16K. Switching to series mode. | 
|  Fri Jul 28 20:39:40 2006, Doug Preddy, Quench Recovery, Restarting refrigerator | 
| Solenoid quenched at about 6:00 tonight. I restarted the compressor, then the cold box and turbines. When cold box
 was at 25K I started flow to the solenoid in parallel cold return.
 | 
|  Sat Jul 22 06:34:14 2006, Experimentor, Quench Recovery, looking good | 
| Donald Arseneau reporting. 
 It is looking pretty good, so I came back in with the intent of energizing
 | 
|  Fri Jul 21 23:36:21 2006, Doug Preddy, Quench Recovery, Final cooldown problems | 
| 80K shield is down to <60K Liquid level not building. Power leads rippling and warming. T1 inlet 85K with 10%heater load.
 Lowered the set point of TI121 to 17K. Shut off flow to the 80K shield to
 |