49
|
Mon Sep 13 10:55:25 2004 |
Doug Preddy | Shut Down | Quench and shutdown | The solenoid quenched on powerlead temps this
morning at 10:00. It is
warming up and the power leads are >200K.Isolating |
|
50
|
Mon Sep 13 13:56:06 2004 |
Doug Preddy | Shut Down | compressor off | compressor off |
|
51
|
Fri Oct 1 11:39:55 2004 |
Doug Preddy | Maintenance | Loading of compressor not working | When the compressor was restarted on Monday,
the remote load button would
not respond. The compressor was shut off. |
|
52
|
Mon Oct 4 09:16:29 2004 |
Doug Preddy | Start Up | Started turbines | Started flow to the turbimes with the solenoid
in parallel warm return. |
|
53
|
Tue Oct 5 07:18:16 2004 |
Doug Preddy | Start Up | adjust compressor discharge pressure | adjusted compressor discharge pressure to
11 Bar |
|
54
|
Wed Oct 6 07:57:01 2004 |
Doug Preddy | Start Up | parallel cold return | Switched to parallel cold return at 4:00 yesterday
afternoon.
6:30 this morning started closing cv155 as |
|
55
|
Wed Oct 6 09:25:54 2004 |
Doug Preddy | Start Up | switch to series mode | switched to series mode |
|
56
|
Thu Oct 7 13:33:20 2004 |
Doug Preddy | Start Up | turned off purifier | turned off purifier |
|
69
|
Wed Oct 20 09:38:17 2004 |
Doug Preddy | Start Up | restarting system | Solenoid tripped off Monday morning due to
high compressor pressure.
Regenerated purifier on Tuesday. Started |
|
70
|
Thu Oct 21 07:16:35 2004 |
Doug Preddy | Start Up | switched to parallel cold return | |
|
71
|
Thu Oct 21 15:41:29 2004 |
Doug Preddy | Start Up | switched to series mode | |
|
72
|
Fri Oct 22 09:15:06 2004 |
Doug Preddy | Start Up | started flow to power leads | Started flow to power leads HIC142 at 0.8.
|
|
73
|
Mon Oct 25 15:44:15 2004 |
Doug Preddy | Normal Running | Power lead temps starting to ripple | Power lead temps starting to ripple at a 1.5min
period. PL flows are
both>250 mm. |
|
74
|
Tue Oct 26 09:45:24 2004 |
Doug Preddy | Normal Running | power leads warming | Flow to power leads dropped to <80 mm. Cycled
HIC142. Temps dropping, flows
>250. |
|
75
|
Fri Oct 29 14:25:23 2004 |
Doug Preddy | Normal Running | power lead flows dropping | Flow is down to <190 mm. temps are starting
to climb. Cycled HIC142 |
|
76
|
Mon Nov 1 07:17:44 2004 |
Doug Preddy | Normal Running | power lead flow gone bad | power temps as follows:
LHE_IN 23
PL_POS 36
|
|
77
|
Thu Nov 4 13:33:49 2004 |
Doug Preddy | Normal Running | Power supply problems | Last night the power supply was ramping up
at a very slow rate. This
morning it was energized,but with no current |
|
78
|
Tue Nov 23 07:47:00 2004 |
Doug Preddy | Quench Recovery | Solenoid quench Nov 21 | Solenoid quenched Nov 21 due to alarge power
bump. Everything tripped off
including vacuum and water pumps. Cold box |
|
79
|
Tue Nov 23 09:30:15 2004 |
Doug Preddy | Quench Recovery | started flow to solenoid | Started flow to solenoid in parallel warm
return. |
|
80
|
Tue Nov 23 11:35:44 2004 |
Doug Preddy | Quench Recovery | Another power bump | Compressor tripped off again due to a power
bump. Meson hall water off, so
vacuum pumps off again.
|
|